Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2012.03–2014.11
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301573 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0A09-591  DC / DC Converter Status Circuit Low Input  


DESCRIPTION

The hybrid vehicle converter (DC/DC converter) controls output voltage (12 V) based on duty ratio signals sent from the power management control ECU.

DTC No. INF Code DTC Detection Condition Trouble Area
P0A09 591 Hybrid vehicle converter voltage switching (VLO) signal circuit malfunction (Open or short to GND)
·

Wire harness or connector

·

Inverter with converter assembly

·

Power management control ECU



WIRING DIAGRAM

A449737E22
4.271,1.448 4.729,1.646 0.458,0.198 10 false A21 0.26,2.438 2.646,3.115 2.385,0.677 10 false Inverter with Converter Assembly 4.323,2.875 4.781,3.073 0.458,0.198 10 false L5 4.656,1.344 5.115,1.542 0.458,0.198 10 false VLO 1.708,1.344 2.167,1.542 0.458,0.198 10 false VLO 2.115,1.333 2.271,1.531 0.156,0.198 10 false 3 4.323,1.25 4.635,1.448 0.313,0.198 10 false 11 4.354,2.688 4.51,2.885 0.156,0.198 10 false 6 4.563,3.292 6.938,3.635 2.375,0.344 10 false Power Management Control ECU 0.271,2.281 0.729,2.479 0.458,0.198 10 false A59 4.667,2.771 4.979,2.969 0.313,0.198 10 false E1 5.479,2.021 5.938,2.219 0.458,0.198 10 false ADC 1.208,1.063 1.521,1.26 0.313,0.198 10 false +B 5.219,1.781 5.813,2.052 0.594,0.271 10 false 300 kΩ 5.552,1.594 6.01,1.792 0.458,0.198 10 false 100 Ω 5.208,2.26 5.802,2.531 0.594,0.271 10 false 100 kΩ 1.677,0.49 2.135,0.688 0.458,0.198 10 false IGCT 2.104,0.375 2.26,0.573 0.156,0.198 10 false 1 3.073,0.656 3.833,1.01 0.76,0.354 10 false IGCT NO. 2 3.156,0.375 3.313,0.573 0.156,0.198 10 false 2 3.635,0.365 3.792,0.563 0.156,0.198 10 false 1 4.49,0.479 5.979,0.958 1.49,0.479 10 false from IGCT relay

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals of the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the power switch on (IG) and wait for 10 seconds or more.



PROCEDURE

1.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

OK

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

NG

CONNECT SECURELY

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

OK

3.CHECK INVERTER WITH CONVERTER ASSEMBLY (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)

NG

CONNECT SECURELY

3.CHECK INVERTER WITH CONVERTER ASSEMBLY (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the A59 inverter with converter assembly connector.


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Turn the power switch on (IG).


e.
A379052E08
1.479,0.188 1.896,0.438 0.417,0.25 0.583,1.51 1.125,0.948 true 0.073,0.104 0.385,0.302 0.313,0.198 10 false *a 1.573,0.24 1.99,0.469 0.417,0.229 10 false A59 0.375,1.521 0.844,1.729 0.469,0.208 10 false IGCT

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A59-1 (IGCT) - Body ground Power switch on (IG) 11 to 14 V


Text in Illustration
*a Front view of wire harness connector
(to Inverter with Converter Assembly)

NOTICE:
·

Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.


·

Turning the power switch on (IG) with the inverter with converter assembly connector connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



HINT:

As there might be an intermittent malfunction in the inverter with converter assembly power source circuit, inspect the following even if the measured voltage is as specified:

·

Installation condition of fuse(s) (before removing fuse(s)) (IGCT circuit)

·

Fuse condition (before and after removing fuse(s)) (IGCT circuit)

·

Connection condition of connectors (IGCT circuit)

·

Wire harness condition (IGCT circuit)

·

Wire harness condition (GND circuit)




f.

Turn the power switch off.


g.

Disconnect the cable from the negative (-) auxiliary battery terminal.


h.

Reconnect the A59 inverter with converter assembly connector.



OK

4.CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)

4.CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM)
a.

Connect an oscilloscope between the power management control ECU terminals specified in the table below.


b.

Turn the power switch on (IG).


c.
U154352E02
0.958,1.26 1.229,1.781 false 1.771,1.188 2.073,1.76 false 0.188,0.063 0.417,0.26 0.229,0.198 10 false *a 1.25,1.792 1.604,1.99 0.354,0.198 10 false VLO 2.094,1.781 2.292,1.979 0.198,0.198 10 false E1 2.781,3.323 3.135,3.521 0.354,0.198 10 false GND 0.75,0.573 1.021,0.74 0.271,0.167 10 false A21 1.885,0.573 2.156,0.74 0.271,0.167 10 false L5

Measure the waveform.

Item Content
Terminal A21-11 (VLO) - L5-6 (E1)
Equipment Setting 5V/DIV., 50ms/DIV.
Condition Power switch on (IG)

Text in Illustration
*a Component with harness connected
(Power Management Control ECU)

OK:

The waveform appears as shown in the illustration.


HINT:

Perform this inspection with the power management control ECU connector connected.




d.

Turn the power switch off.



OK

5.CLEAR DTC

NG

8.CHECK POWER MANAGEMENT CONTROL ECU (RESISTANCE VALUE OF VLO)
5.CLEAR DTC
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Clear DTCs and freeze frame data.


e.

Turn the power switch off.



NEXT

6.CHECK DTC OUTPUT (HYBRID CONTROL)
6.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Turn the power switch on (READY).


b.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


c.

Check if DTCs are output.

Result:
Result Proceed to
P0A09-591 is not output. A
P0A09-591 is output again. B



d.

Turn the power switch off.



A

7.CHECK FOR INTERMITTENT PROBLEMS

B

7.CHECK FOR INTERMITTENT PROBLEMS

OK

NG

REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA

8.CHECK POWER MANAGEMENT CONTROL ECU (RESISTANCE VALUE OF VLO)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the A59 inverter with converter assembly connector.


c.
U154304E03
1.177,1.802 1.375,0.927 false 1,1.833 1.333,2.021 0.333,0.188 10 false VLO 0.146,0.094 0.458,0.281 0.313,0.188 10 false *a 0.354,1.063 0.677,1.25 0.323,0.188 10 false A59

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A59-3 (VLO) - Body ground Power switch off 370 to 430 kΩ


Text in Illustration
*a Front view of wire harness connector
(to Inverter with Converter Assembly)


d.

Reconnect the A59 inverter with converter assembly connector.



OK

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

NG

9.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU)
9.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the A59 inverter with converter assembly connector.


c.

Disconnect the A21 power management control ECU connector.


d.
U154318E02
1.281,1.271 1.906,0.531 false 0.958,3.927 1.281,4.271 false 0.229,0.115 0.49,0.344 0.26,0.229 10 false *a 0.229,2.198 0.49,2.427 0.26,0.229 10 false *b 0.365,1.375 0.635,1.542 0.271,0.167 10 false A59 1.281,3.844 1.552,4.01 0.271,0.167 10 false A21 1.948,0.417 2.448,0.646 0.5,0.229 10 false VLO 1.323,4.229 1.823,4.458 0.5,0.229 10 false VLO

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A59-3 (VLO) - A21-11 (VLO) Power switch off Below 1 Ω
A59-3 (VLO) or A21-11 (VLO) - Body ground and other terminals Power switch off 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
*b Rear view of wire harness connector
(to Power Management Control ECU)


e.

Reconnect the A59 inverter with converter assembly connector.


f.

Reconnect the A21 power management control ECU connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR