Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2012.03–2012.10
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301573 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0A10-263  DC / DC Converter Status Circuit High Input  


DESCRIPTION

Refer to the description for DTC P0A08-264 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A08-264).

DTC No. INF Code DTC Detection Condition Trouble Area
P0A10 263 Short to +B in the hybrid vehicle converter (DC/DC converter) NODD signal line
·

Wire harness or connector

·

Inverter with converter assembly

·

Power management control ECU



WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A08-264 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A08-264).

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals of the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the power switch on (IG) and wait for 10 seconds or more.



PROCEDURE

1.CHECK POWER MANAGEMENT CONTROL ECU (NODD)
a.

Turn the power switch on (READY).


b.
U154400E03
0.865,1.844 1.135,2.354 false 1.823,1.698 2.094,2.333 false 0.656,0.969 0.917,1.146 0.26,0.177 10 false A21 1.135,2.365 1.583,2.542 0.448,0.177 10 false NODD 2.115,2.323 2.385,2.5 0.271,0.177 10 false E1 0.135,0.052 0.292,0.229 0.156,0.177 10 false *a 1.99,0.958 2.25,1.135 0.26,0.177 10 false L5

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A21-21 (NODD) - L5-6 (E1) Power switch on (READY) 5 to 7 V


Text in Illustration
*a Component with harness connected
(Power Management Control ECU)


c.

Turn the power switch off.



OK

2.CLEAR DTC

NG

5.CHECK POWER MANAGEMENT CONTROL ECU (NODD)
2.CLEAR DTC

NEXT

3.CHECK DTC OUTPUT (HYBRID CONTROL)
3.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (READY).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check if DTCs are output.

Result:
Result Proceed to
P0A10-263 is not output. A
P0A10-263 is output again. B



e.

Turn the power switch off.



A

4.CHECK FOR INTERMITTENT PROBLEMS

B

4.CHECK FOR INTERMITTENT PROBLEMS

OK

NG

REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA

5.CHECK POWER MANAGEMENT CONTROL ECU (NODD)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the A59 inverter with converter assembly connector.


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Turn the power switch on (IG).


e.
U154303E06
1.26,1.031 0.677,1.26 false 0.104,0 0.292,0.167 0.188,0.167 10 false *a 0.135,1.198 0.625,1.354 0.49,0.156 10 false NODD 1.573,1.76 1.833,1.938 0.26,0.177 10 false A59

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A59-12 (NODD) - Body ground Power switch on (IG) Below 1 V


Text in Illustration
*a Front view of wire harness connector
(to Inverter with Converter Assembly)

NOTICE:

Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



f.

Turn the power switch off.


g.

Disconnect the cable from the negative (-) auxiliary battery terminal.


h.

Reconnect the A59 inverter with converter assembly connector.



OK

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

NG

6.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU)
6.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the A59 inverter with converter assembly connector.


c.

Disconnect the A21 power management control ECU connector.


d.

Connect the cable to the negative (-) auxiliary battery terminal.


e.

Turn the power switch on (IG).


f.
U154317E03
1.167,1.375 1.406,0.594 false 0.958,3.99 1.281,4.229 false 0.229,0.115 0.49,0.344 0.26,0.229 10 false *a 0.229,2.198 0.49,2.427 0.26,0.229 10 false *b 0.354,1.375 0.625,1.542 0.271,0.167 10 false A59 1.292,3.865 1.563,4.031 0.271,0.167 10 false A21 1.438,0.51 1.938,0.74 0.5,0.229 10 false NODD 1.323,4.156 1.823,4.385 0.5,0.229 10 false NODD

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A59-12 (NODD) or A21-21 (NODD) - Body ground Power switch on (IG) Below 1 V


Text in Illustration
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
*b Rear view of wire harness connector
(to Power Management Control ECU)

NOTICE:

Turning the power switch on (IG) with the inverter with converter assembly connector and the power management control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



g.

Turn the power switch off.


h.

Disconnect the cable from the negative (-) auxiliary battery terminal.


i.

Reconnect the A59 inverter with converter assembly connector.


j.

Reconnect the A21 power management control ECU connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR