Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2015.08–2016.05
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301573 HYBRID CONTROL SYSTEM D

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  INFORMATION / FREEZE FRAME DATA  


FREEZE FRAME DATA


HINT:

The power management control ECU records vehicle and driving condition information as freeze frame data the moment a DTC is stored. It can be used for estimating or duplicating the vehicle conditions that were present when the malfunction occurred. To confirm the details of the hybrid control system, check the detailed information for the DTC information code in the Data List (INF code).


a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


e.

Select a DTC in order to display its freeze frame data.


f.

Check the freeze frame information recorded with the DTC.

FREEZE FRAME DATA
Tester Display Measurement Item/Range Suspected Vehicle Status When Malfunction Occurs
Engine Coolant Temp
·

Engine coolant temperature/

·

Min.: -40°C (-40°F), Max.: 215°C (419°F)


Cold or warmed-up engine
Engine Revolution
·

Engine speed/

·

Min.: 0 rpm, Max.: 16383 rpm


Engine speed
Vehicle Spd
·

Vehicle speed/

·

Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph)


Stopped, or driving (at low, medium, or high speeds)
Engine Run Time
·

Elapsed time after starting engine/

·

Min.: 0 s, Max.: 65535 s


After the power switch is turned on (READY), elapsed time from initial engine start until the power switch is turned off.
+B
·

Auxiliary battery voltage/

·

Min.: 0.00 V, Max.: 65.53 V


Auxiliary battery condition
Accel Pedal Pos #1
·

Accelerator pedal position sensor No. 1/

·

Min.: 0.0%, Max.: 100.0%


Idling, accelerating, or decelerating
Accel Pedal Pos #2
·

Accelerator pedal position sensor No. 2/

·

Min.: 0%, Max.: 100%


For comparison to accelerator pedal position sensor No. 1
Ambient Temperature
·

Ambient air temperature/

·

Min.: -40°C (-40°F), Max.: 215°C (419°F)


Hot or cold weather
Intake Air Temperature
·

Intake air temperature/

·

Min.: -40°C (-40°F), Max.: 140°C (284°F)


Hot or cold weather
DTC Clear Warm Up
·

The number of times the engine is warmed up after clearing DTCs/

·

Min.: 0, Max.: 255


Frequency of malfunction recurrence after clearing DTCs
DTC Clear Run Distance
·

Drive distance after clearing DTCs/

·

Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)


Frequency of malfunction recurrence after clearing DTCs
DTC Clear Min
·

Elapsed time after clearing DTCs/

·

Min.: 0 min, Max.: 65535 min


Elapsed time after clearing DTCs
MAP
·

Intake manifold pressure/

·

Min.: 0 kPa, Max.: 255 kPa


-
Atmosphere Pressure
·

Atmospheric pressure/

·

Min.: 0 kPa, Max.: 255 kPa


Vehicle driving elevation
Ready Signal
·

Power switch condition/

·

ON or OFF


-
Motor(MG2) Revolution
·

MG2 revolution/

·

Min.: -32768 rpm, Max.: 32767 rpm


-
Motor(MG2) Torq
·

MG2 torque/

·

Min.: -4096 Nm, Max.: 4095.87 Nm


-
M(MG2) Trq Exec Val
·

MG2 torque execution value/

·

Min.: -4096 Nm, Max.: 4095.87 Nm


-
Generator(MG1) Rev
·

MG1 revolution/

·

Min.: -32768 rpm, Max.: 32767 rpm


-
Generator(MG1) Torq
·

MG1 torque/

·

Min.: -4096.00 Nm, Max.: 4095.87 Nm


-
G(MG1) Trq Exec Val
·

MG1 torque execution value/

·

Min.: -4096.00 Nm, Max.: 4095.87 Nm


-
Regenerative Brake Torq
·

MG1 regenerative braking execution torque/

·

Min.: -4096.0 Nm, Max.: 4095.0 Nm


-
Rqst Regen Brake Torq
·

Requested MG1 regenerative braking torque/

·

Min.: -4096.0 Nm, Max.: 4095.0 Nm


-
Inverter Temp-(MG1)
·

Generator inverter temperature/

·

Min.: 15°C (59°F), Max.: 150°C (302°F)


-
Inverter Temp-(MG2)
·

Motor inverter temperature/

·

Min.: 15°C (59°F), Max.: 150°C (302°F)


-
Motor Temp No2
·

MG1 temperature/

·

Min.: -40°C (-40°F), Max.: 215°C (419°F)


-
Motor Temp No1
·

MG2 temperature/

·

Min.: -40°C (-40°F), Max.: 215°C (419°F)


Accelerator Degree
·

Accelerator pedal depressed angle/

·

Min.: 0.0%, Max.: 127.5%


Idling, accelerating, or decelerating
Request Power
·

Request engine power/

·

Min.: 0 W, Max.: 655350 W


-
Target Engine Rev
·

Target engine speed/

·

Min.: 0 rpm, Max.: 65535 rpm


-
Engine Rev (Sensor)
·

Engine speed/

·

Min.: 0 rpm, Max.: 16383 rpm


-
State of Charge (All Bat)
·

HV battery state of charge/

·

Min.: 0.0%, Max.: 100.0%


State of charge of HV battery
Master Cylinder Ctrl Trq
·

Master cylinder control torque/

·

Min.: -4096.0 Nm, Max.: 4095.0 Nm


Brake force requested by driver
Power Resource VB
·

HV battery voltage/

·

Min.: 0.0 V, Max.: 6553.5 V


HV battery condition
Power Resource IB
·

HV battery current/

·

Min.: -327.68 A, Max.:327.67 A


HV battery condition
Bat1 Pwr Resourc IB Sens2
·

HV battery current/

·

Min.: -327.68 A, Max.: 327.67 A


-
Power Supply Sensor Voltage
·

Power supply sensor voltage (VC)/

·

Min.: 0.00 V, Max.: 79.99 V


-
VL-Voltage before Boosting
·

High voltage before it is boosted/

·

Min.: 0 V, Max.: 360 V


-
VH-Voltage after Boosting
·

High voltage after it is boosted/

·

Min.: 0 V, Max.: 1000 V


-
Boost Ratio
·

Boost converter boost ratio/

·

Min.: 0.0%, Max.: 127.5%


-
Drive Condition ID Drive condition ID/

Engine stopped: 0

Engine about to be stopped: 1

Engine about to be started: 2

Engine operated or operating: 3


Engine operating condition
Shift Sensor Main
·

Shift sensor (Main) voltage/

·

Min.: 0.00 V, Max.: 4.98 V


-
Shift Sensor Sub
·

Shift sensor (Sub) voltage/

·

Min.: 0.00 V, Max.: 4.98 V


-
Shift Sensor Select Main
·

Select sensor (Main) voltage/

·

Min.: 0.00 V, Max.: 4.98 V


-
Shift Sensor Select Sub
·

Select sensor (Sub) voltage/

·

Min.: 0.00 V, Max.: 4.98 V


-
Shift Sensor Shift Pos
·

Shift position/

·

P/R/N/D/B


Selected shift position
Crank Position
·

Crankshaft position/

·

Min.: -128 °CA, Max.: 127 °CA


-
A/C Consumption Pwr
·

A/C consumption power/

·

Min.: 0 W, Max.: 12750 W


-
Short Wave Highest Val
·

Waveform voltage in leak detection circuit in battery smart unit/

·

Min.: 0.00 V, Max.: 4.98 V


Electrical leakage presence
MG1 Control Mode
·

MG1 control mode/

·

PWM: 0/Variable PWM: 1/Rectangular wave: 2


Operating state of inverter with converter assembly
MG1 Carrier Frequency
·

MG1 carrier frequency/

·

0.75kHz/1.25kHz/2.50kHz/3.75kHz/5.00kHz/10.00kHz


Operating state of inverter with converter assembly
MG2 Control Mode
·

MG2 control mode/

·

PWM: 0/Variable PWM: 1/Rectangular wave: 2


Operating state of inverter with converter assembly
MG2 Carrier Frequency
·

MG2 carrier frequency/

·

0.75kHz/1.25kHz/2.50kHz/3.75kHz/5.00kHz


Operating state of inverter with converter assembly
Num of Current Code
·

The number of current DTCs/

·

Min.: 0, Max.: 255


-
Num of History Code
·

The number of history DTCs/

·

Min.: 0, Max.: 255


-
Calculate Load
·

Calculated load/

·

Min.: 0.0%, Max.: 100.0%


-
Throttle Position
·

Throttle position sensor/

·

Min.: 0.0%, Max.: 100.0%


Idling, accelerating, or decelerating
DCDC Cnv Tar Pulse Duty
·

Target auxiliary battery voltage/

·

Min.: 0.0%, Max.: 399.9%


Auxiliary battery condition
Inverter Coolant Water Temperature
·

Inverter coolant temperature/

·

Min.: -40°C (-40°F), Max.: 110°C (230°F)


Hot or cold weather
Cooling Fan 0
·

Cooling fan operating condition/

·

Min.: 0.0%, Max.: 127.5%


Cooling fan operating condition
Cooling Fan Relay
·

BATT FAN relay/

·

ON or OFF


Cooling fan operating condition
Inverter W/P Revolution
·

Inverter water pump assembly speed/

·

Min.: 0 rpm, Max.: 15000 rpm


Operating state of inverter water pump assembly
Prohibit DC/DC conv sig
·

DC/DC converter prohibition signal/

·

ON or OFF


Operating state of inverter with converter assembly
DC/DC Converter Status Voltage
·

DC/DC converter status voltage/

·

Min.: 0.00 V, Max.: 4.99 V


-
EV Request
·

EV drive mode transition availability/

·

ON or OFF


EV drive mode on or off
TRC OFF Switch
·

TRC OFF switch condition/

·

OFF / TRC / TRC/VSC


VSC OFF switch on or off
Starter Switch
·

Starter ON/OFF signal/

·

OFF or ON


-
Inv-T (MG1) aftr IG-ON
·

Generator inverter temperature soon after power switch on (IG)/

·

Min.: 15°C (59°F), Max.: 150°C (302°F)


-
Inv-T (MG2) aftr IG-ON
·

Motor inverter temperature soon after power switch on (IG)/

·

Min.: 15°C (59°F), Max.: 150°C (302°F)


-
Mtr-T (MG2) aftr IG-ON
·

MG2 temperature soon after power switch on (IG)/

·

Min.: -40°C (-40°F), Max.: 215°C (419°F)


-
Conv-Tmp after IG-ON
·

Boost converter temperature soon after power switch on (IG)/

·

Min.: 15°C (59°F), Max.: 150°C (302°F)


-
SOC after IG-ON
·

HV battery state of charge after power switch on (IG)/

·

Min.: 0.0%, Max.: 127.5%


HV battery condition
Inv-Temp (MG1) Max
·

Generator inverter maximum temperature/

·

Min.: 15°C (59°F), Max.: 150°C (302°F)


-
Inv-Temp (MG2) Max
·

Motor inverter maximum temperature/

·

Min.: 15°C (59°F), Max.: 150°C (302°F)


-
Mtr-Temp (MG2) Max
·

MG2 maximum temperature/

·

Min.: -40°C (-40°F), Max.: 215°C (419°F)


-
Converter Temp Max
·

Boost converter maximum temperature/

·

Min.: 15°C (59°F), Max.: 150°C (302°F)


-
Status of Charge Max
·

Maximum status of charge/

·

Min.: 0.0%, Max.: 127.5%


HV battery condition
Status of Charge Min
·

Minimum status of charge/

·

Min.: 0.0%, Max.: 127.5%


HV battery condition
Stop Light Switch
·

Stop light switch condition/

·

ON or OFF


Brake pedal depressed
Auxiliary Batt Temperature
·

Auxiliary battery temperature/

·

Min.: -40°C (-40°F), Max.: 215°C (419°F)


-
Collision Signal (Airbag)
·

Detection of collision by airbag ECU assembly/

·

ON or OFF


Operating state of airbag ECU assembly
TC Terminal
·

TC terminal state/

·

ON or OFF


-
Inter Lock Switch
·

Interlock switch condition/

·

ON or OFF


Power switch on (IG), inverter cover, high-voltage input cables or service plug grip not installed: ON
EV Switch
·

EV drive mode switch (combination switch assembly) condition/

·

ON or OFF


EV drive mode switch (combination switch assembly) on or off
Back Up Lamp Relay
·

Back up light switch condition/

·

ON or OFF


Shift lever in R: ON
ECO Mode
·

ECO drive mode signal/

·

ON or OFF


ECO drive mode on or off
Prohibit Charge for P Pos
·

HV battery charge in park (P) selected prohibition state/

·

ON or OFF


-
Vehicle Parking (T/M Ctrl)
·

Indicates whether vehicle being driven or stopped/

·

ON or OFF


-
Shift Pos Status (T/M Ctrl)
·

Indicates whether park (P) is selected/

·

Not P / Run / P


-
Shift P Permission Signal
·

Indicates whether selection of park (P) is permitted/

·

ON or OFF


-
DC/DC Cnv Temp (Upper)
·

Boost converter temperature (upper)/

·

Min.: 15°C (59°F), Max.: 150°C (302°F)


-
Safing Signal (Airbag)
·

Safing state of the airbag ECU assembly/

·

ON or OFF


Operating state of airbag ECU assembly
DC/DC Cnv Temp (Lower)
·

Boost converter temperature (lower)/

·

Min.: 15°C (59°F), Max.: 150°C (302°F)


-
Normal Signal for A/B ECU
·

Control state of airbag ECU assembly/

·

ON or OFF


Operating state of airbag ECU assembly
Mtr-T (MG1) aftr IG-ON
·

MG1 temperature soon after power switch on (IG)/

·

Min.: -40°C (-40°F), Max.: 215°C (419°F)


-
Mtr-Temp (MG1) Max
·

MG1 maximum temperature/

·

Min.: -40°C (-40°F), Max.: 215°C (419°F)


-
Overvoltage Input to Conv
·

Boost converter overvoltage detection/

·

ON or OFF


-
Overvoltage Input to Inv
·

Inverter overvoltage detection/

·

ON or OFF


-
Emergency Shutdown
·

Inverter emergency shutdown/

·

ON or OFF


Operating state of inverter with converter assembly
MG1 Inverter Shutdown
·

Generator inverter shutdown/

·

ON or OFF


Operating state of inverter with converter assembly
MG1 Inverter Fail
·

Generator inverter failure/

·

ON or OFF


Operating state of inverter with converter assembly
MG2 Inverter Shutdown
·

Motor inverter shutdown/

·

ON or OFF


Operating state of inverter with converter assembly
MG2 Inverter Fail
·

Motor inverter failure/

·

ON or OFF


Operating state of inverter with converter assembly
Conv Shutdown
·

Boost converter shutdown/

·

ON or OFF


Operating state of inverter with converter assembly
Converter Fail
·

Boost converter failure/

·

ON or OFF


Operating state of inverter with converter assembly
P Pos SW Terminal Vol
·

Indicates voltage at the P position switch terminal/

·

Min.: 0.00 V, Max.: 4.98 V


-
Internal Shift Position
·

ECU internal shift position/

·

P/R/N/D/B


Selected shift position
P Rq Malfunction (T/M Ctrl)
·

Indicates whether park (P) selection request is normal/

·

Normal or Abnormal


-
P Request (T/M Ctrl)
·

Indicates whether selection of park (P) is requested/

·

ON or OFF


-
T/M Control ECU State
·

Indicates the control condition of the transmission control ECU/

·

Normal or Abnormal


-
T/M ECU Pulse Consec Err
·

Indicates consecutive communication errors with the transmission control ECU/

·

Normal or Abnormal


-
T/M ECU Pulse Single Err
·

Indicates a single communication error with the transmission control ECU/

·

Normal or Abnormal


-
HV Start Condition
·

Indicates the hybrid start condition/

·

Norml / Pr A/C / Remote


-
(Inverter) W/P Run Control Duty
·

Inverter water pump motor drive request duty/

·

Min.: 0.00%, Max.: 100.00%


Operating state of inverter water pump assembly
Engine Stop Request
·

Engine stop request/

·

Request or No


Engine operating conditions
Engine Idling Request
·

Engine idling request/

·

Request or No


Engine operating conditions
Main Batt Charging Rqst
·

HV battery charging request/

·

Request or No


HV battery condition
Aircon Request
·

Engine starting request from A/C amplifier/

·

Request or No


-
Engine Warming Up Rqst
·

Engine warm-up request/

·

Request or No


Engine operating conditions
SMRP Status
·

Operating state of SMRP/

·

ON or OFF


Cannot be confirmed using the GTS. Use an oscilloscope.
SMRB Status
·

Operating state of SMRB/

·

ON or OFF


-
SMRG Status
·

Operating state of SMRG/

·

ON or OFF


-
SMRP Control Status
·

Commanded state of SMRP/

·

ON or OFF


Cannot be confirmed using the GTS. Use an oscilloscope.
SMRB Control Status
·

Commanded state of SMRB/

·

ON or OFF


-
SMRG Control Status
·

Commanded state of SMRG/

·

ON or OFF


-
MG1 Gate Status
·

MG1 gate status/

·

ON or OFF


Operating state of inverter with converter assembly
MG2 Gate Status
·

MG2 gate status/

·

ON or OFF


Operating state of inverter with converter assembly
Converter Gate Status
·

Boost converter gate status/

·

ON or OFF


Operating state of inverter with converter assembly
Aircon Gate Status
·

While A/C inverter a being shut off/

·

ON or OFF


Operating state of inverter with converter assembly
Converter Carrier Freq
·

Boost converter signal carrier frequency/

·

9.55kHz/9.13kHz/8.71kHz/8.29kHz/7.87kHz/7.45kHz/ 4.8kHz


Operating state of inverter with converter assembly
Delta SOC
·

Difference between maximum and minimum values of SOC/

·

Min.: 0.0%, Max.: 127.5%


SOC variance
Batt Pack Current Val
·

HV battery current/

·

Min.: -327.68 A, Max.: 327.67 A


HV battery charge/discharge status
·

Amount of current during discharge is displayed with positive values

·

Amount of current during charge is displayed with negative values


Bat No. 1 Sens No. 2 Cur Val
·

HV battery current/

·

Min.: -327.68 A, Max.: 327.67 A


HV battery current sensor circuit
Inhaling Air Temp
·

HV battery intake air temperature/

·

Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)


-
Inhaling Air Temp2
·

HV battery intake air temperature/

·

Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)


-
VMF Fan Motor Voltage1
·

Battery blower motor monitoring voltage/

·

Min.: 0.0 V, Max.: 25.5 V


Operating state of cooling fan
Auxiliary Battery Vol
·

Auxiliary battery voltage/

·

Min.: -40.00 V, Max.: 39.99 V


Auxiliary battery condition
Charge Control Value
·

Charge control wattage sent from battery smart unit to power management control ECU/

·

Min.: -64.0 kW, Max.: 63.5 kW


Charge amount of HV battery
Discharge Control Value
·

Discharge control wattage sent from battery smart unit to power management control ECU/

·

Min.: -64.0 kW, Max.: 63.5 kW


Discharge amount of HV battery
Cooling Fan Mode1
·

Battery cooling fan operation mode/

·

Min.: 0, Max.: 6


HV battery cooling fan activation condition
·

Cooling fan stopped: 0

·

Low speed drive - high speed drive: 1-6


ECU Control Mode
·

Battery control mode/

·

Min.: 0, Max.: 4


HV battery control status
Standby Blower Request
·

Battery cooling fan Lo speed requested/

·

ON or OFF


Operating state of cooling fan
Temp of Batt TB1
·

Battery module temperature/

·

Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)


HV battery temperature
Temp of Batt TB2
·

Battery module temperature/

·

Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)


HV battery temperature
Temp of Batt TB3
·

Battery module temperature/

·

Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)


HV battery temperature
Temp of Batt TB4
·

Battery module temperature/

·

Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)


HV battery temperature
Temp of Batt TB5
·

Battery module temperature/

·

Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)


HV battery temperature
Temp of Batt TB6
·

Battery module temperature/

·

Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)


HV battery temperature
Battery Block Vol -V01
·

Battery block voltage/

·

Min.: 0.00 V, Max.: 79.99 V


Each HV battery block voltage variance
Battery Block Vol -V02
·

Battery block voltage/

·

Min.: 0.00 V, Max.: 79.99 V


Each HV battery block voltage variance
Battery Block Vol -V03
·

Battery block voltage/

·

Min.: 0.00 V, Max.: 79.99 V


Each HV battery block voltage variance
Battery Block Vol -V04
·

Battery block voltage/

·

Min.: 0.00 V, Max.: 79.99 V


Each HV battery block voltage variance
Battery Block Vol -V05
·

Battery block voltage/

·

Min.: 0.00 V, Max.: 79.99 V


Each HV battery block voltage variance
Battery Block Vol -V06
·

Battery block voltage/

·

Min.: 0.00 V, Max.: 79.99 V


Each HV battery block voltage variance
Battery Block Vol -V07
·

Battery block voltage/

·

Min.: 0.00 V, Max.: 79.99 V


Each HV battery block voltage variance
Battery Block Vol -V08
·

Battery block voltage/

·

Min.: 0.00 V, Max.: 79.99 V


Each HV battery block voltage variance
Cell High Voltage (LV1)
·

HV Battery Cell High Voltage/

·

ON or OFF


-
Cell High Voltage (LV2)
·

HV Battery Cell High Voltage/

·

ON or OFF


-
Cell Low Voltage (LV1)
·

HV Battery Cell Low Voltage/

·

ON or OFF


-
Cell Discharge Low
·

HV Battery Cell Low Voltage/

·

ON or OFF


-
Cell Discharge High
·

HV Battery Cell Low Voltage/

·

ON or OFF


-
Pattern Switch (PWR/M)
·

POWER mode transition availability/

·

ON or OFF


-
Detail Code 1
·

Number of detailed information stored by information code/

·

Min.: 0, Max.: 32767


-
Detail Code 2
·

Number of detailed information stored by information code/

·

Min.: 0, Max.: 32767


-
Detail Code 3
·

Number of detailed information stored by information code/

·

Min.: 0, Max.: 32767


-
Detail Code 4
·

Number of detailed information stored by information code/

·

Min.: 0, Max.: 32767


-
Detail Code 5
·

Number of detailed information stored by information code/

·

Min.: 0, Max.: 32767


-



INFORMATION


HINT:

Similar to freeze frame data, the power management control ECU also records vehicle and driving condition information as INFORMATION (INF code) at the moment a DTC is stored.


a.

Select the information item which has an INF code from among INFORMATION 1 to 5.


b.

Check the information for the DTC.

INFORMATION
Tester Display Measurement Item/Range Suspected Vehicle Status When Malfunction Occurs
Information 1 to 5 INF code Identification of malfunctioning system
Generator(MG1) Rev
·

MG1 revolution/

·

Min.: -16384 rpm, Max.: 16256 rpm


MG1 speed
·

Forward rotation appears as "+"

·

Backward rotation appears as "-"


Motor(MG2) Revolution
·

MG2 revolution/

·

Min.: -16384 rpm, Max.: 16256 rpm


MG2 speed
·

Forward rotation appears as "+"

·

Backward rotation appears as "-"


Generator(MG1) Torq
·

MG1 torque/

·

Min.: -512 Nm, Max.: 508 Nm


When MG1 rotates in "+" direction:
·

Torque appears as "+" while MG1 discharges

·

Torque appears as "-" while MG1 charges


When MG1 rotates in "-" direction:
·

Torque appears as "-" while MG1 discharges

·

Torque appears as "+" while MG1 charges


Motor(MG2) Torq
·

MG2 torque/

·

Min.: -512 Nm, Max.: 508 Nm


When MG2 rotates in "+" direction:
·

Torque appears as "+" while MG2 discharges

·

Torque appears as "-" while MG2 charges


When MG2 rotates in "-" direction:
·

Torque appears as "-" while MG2 discharges

·

Torque appears as "+" while MG2 charges


Request Power
·

Request engine power/

·

Min.: 0 kW, Max.: 255 kW


Engine power output requested to ECM
Engine Spd
·

Engine speed/

·

Min.: 0 rpm, Max.: 16320 rpm


Engine speed
Master Cylinder Ctrl Trq
·

Master cylinder control torque/

·

Min.: -512 Nm, Max.: 508 Nm


Brake force requested by driver
State of Charge
·

HV battery state of charge/

·

Min.: 0.0%, Max.: 100.0%


Charge of amount HV battery
WOUT Control Power
·

Power value discharge control/

·

Min.: 0 W, Max.: 81600 W


Discharge amount of HV battery
WIN Control Power
·

Power value charge control/

·

Min.: -40800 W, Max.: 0 W


Charge amount of HV battery
Drive Condition ID Drive condition ID/
·

Engine stopped: 0

·

Engine about to be stopped: 1

·

Engine about to be started: 2

·

Engine operated or operating: 3


Engine operating condition
Power Resource VB
·

HV battery voltage/

·

Min.: 0 V, Max.: 510 V


HV battery voltage
Power Resource IB
·

HV battery charge/discharge status/

·

Min.: -256 A, Max.: 254 A


HV battery charge and discharge current
·

Amount of current during discharge is indicated with positive values

·

Amount of current during charge is indicated with negative values


Shift Sensor Shift Pos
·

Shift position/

·

P/R/N/D/B


Shift lever position sensor
Auxiliary Batt Voltage
·

Auxiliary battery voltage/

·

Min.: 0.00 V, Max.: 20.00 V


Auxiliary battery condition
VL-Voltage before Boosting
·

High voltage before it is boosted/

·

Min.: 0 V, Max.: 360 V


High voltage level before it is boosted
VH-Voltage after Boosting
·

High voltage after it is boosted/

·

Min.: 0 V, Max.: 1000 V


High voltage level after it is boosted
The Time of Ignition ON
·

Elapsed time after power switch on (IG)/

·

Min.: 0 min, Max.: 255 min


Time elapsed with power switch on (IG)
Vehicle Speed(Max)
·

Maximum vehicle speed/

·

Min.: -256 km/h (-159 mph), Max.: 254 km/h (158 mph)


Maximum vehicle speed
Engine Stop Request
·

Engine stop request/

·

Yes or No


Engine stop request
Engine Idling Request
·

Engine idling request/

·

Yes or No


Idle stop request
Engine Fuel Cut
·

Engine fuel cut/

·

Yes or No


Fuel cut
Main Batt Charging Rqst
·

HV battery charging request/

·

Yes or No


HV battery charging request
Engine Warming Up Rqst
·

Engine warming up request/

·

Yes or No


Engine warm-up request
Stop Switch
·

Stop light switch ON condition/

·

Yes or No


Brake pedal depressed or released
Exclusive Information 1
·

Indicates exclusive information/

·

Min.: -127, Max.: 127


Exclusive information linked to Information
Exclusive Information 2
·

Indicates exclusive information/

·

Min.: -127, Max.: 127


Exclusive information linked to Information
Exclusive Information 3
·

Indicates exclusive information/

·

Min.: -127, Max.: 127


Exclusive information linked to Information
Exclusive Information 4
·

Indicates exclusive information/

·

Min.: -127, Max.: 127


Exclusive information linked to Information
Exclusive Information 5
·

Indicates exclusive information/

·

Min.: -127, Max.: 127


Exclusive information linked to Information
Exclusive Information 6
·

Indicates exclusive information/

·

Min.: -127, Max.: 127


Exclusive information linked to Information
Exclusive Information 7
·

Indicates exclusive information/

·

Min.: -127, Max.: 127


Exclusive information linked to Information
Occurrence Order Occurrence sequence of information Occurrence sequence of information
Cnv Tmp (Upper)
·

Boost converter temperature (upper)/

·

Min.: 15°C (59°F), Max.: 150°C (302°F)


Boost converter temperature
Cnv Temp (Lower)
·

Boost converter temperature (lower)/

·

Min.: 15°C (59°F), Max.: 150°C (302°F)


Boost converter temperature
Generator Temp
·

MG1 temperature/

·

Min.: -40°C (-40°F), Max.: 215°C (419°F)


MG1 temperature
MG1 Carrier Frequency
·

MG1 carrier Frequency/

·

0.75kHz/1.25kHz/2.50kHz/3.75kHz/5.00kHz/10.00kHz


MG1 inverter carrier frequency
MG2 Carrier Frequency
·

MG2 carrier frequency/

·

0.75kHz/1.25kHz/2.50kHz/3.75kHz/5.00kHz


MG2 inverter carrier frequency
Motor Temp
·

MG2 temperature/

·

Min.: -40°C (-40°F), Max.: 215°C (419°F)


MG2 carrier temperature
Converter Carrier Freq
·

Boost converter signal carrier frequency/

·

9.55kHz/9.13kHz/8.71kHz/8.29kHz/7.87kHz/7.45kHz/4.8kHz


Converter carrier frequency
Inverter Temp (MG1)
·

Generator inverter temperature/

·

Min.: 15°C (59°F), Max.: 150°C (302°F)


Generator inverter temperature
MG1 Control Mode
·

MG1 control mode/

·

PWM: 0/Variable PWM: 1/Rectangular wave: 2


MG1 control mode
Inverter Temp (MG2)
·

Motor inverter temperature/

·

Min.: 15°C (59°F), Max.: 150°C (302°F)


Motor inverter temperature
MG2 Control Mode
·

MG2 control mode/

·

PWM: 0/Variable PWM: 1/Rectangular wave: 2


MG2 control mode
Boost Ratio
·

Boost converter boost ratio/

·

Min.: 0.0%, Max.: 100.0%


Boost condition
MG1 Inverter Shutdown
·

Generator inverter shutdown/

·

ON or OFF


Generator inverter shutdown: ON
HV Coolant Temperature
·

HV coolant temperature/

·

Min.: -40°C (-40°F), Max.: 110°C (230°F)


HV coolant temperature
MG2 Inverter Shutdown
·

Motor inverter shutdown/

·

ON or OFF


Motor inverter shutdown: ON
Accel Sensor Main
·

Accelerator pedal depressed angle/

·

Min.: 0.0%, Max.: 100.0%


Idling, accelerating, or decelerating
Conv Shutdown
·

Boost converter shutdown/

·

ON or OFF


Boost converter shutdown: ON