RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301573 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P3232-749  Short to GND in Blocking of HV Gate Connection  


DESCRIPTION

The power management control ECU sends a shutdown signal to the inverter with converter assembly (MG ECU) to shut down the power supply to MG2 and MG1.

DTC No. INF Code DTC Detection Condition Trouble Area
P3232 749 Short to GND in the emergency shutdown signal line while the IGBTs are being shut down.
·

Wire harness or connector

·

Power management control ECU

·

Inverter with converter assembly



WIRING DIAGRAM

A237478E04
4.571,2.186 4.854,2.364 0.283,0.178 10 A22 4.571,2.333 6.705,2.511 2.133,0.178 10 Power Management Control ECU 0.437,2.2 0.789,2.378 0.352,0.178 10 A59 0.437,2.333 2.528,2.511 2.092,0.178 10 Inverter with Converter Assembly 4.812,1.053 5.238,1.219 0.426,0.166 10 HSDN 1.937,1.053 2.363,1.219 0.426,0.166 10 HSDN 2.056,0.787 2.364,0.953 0.308,0.166 10 +B2 2.129,0.45 2.347,0.617 0.218,0.166 10 +B 3.36,0.417 4.280,0.698 0.920,0.281 10 to IGCT Relay 2.414,0.329 2.632,0.495 0.218,0.166 10 10 2.414,0.675 2.632,0.841 0.218,0.166 10 9 2.414,1.071 2.609,1.238 0.195,0.166 10 31 4.548,1.071 4.743,1.238 0.195,0.166 10 31 5.959,0.432 6.176,0.598 0.218,0.166 10 +B 2.405,1.37 2.622,1.537 0.218,0.166 10 28 2.405,1.716 2.622,1.882 0.218,0.166 10 27 1.937,1.487 2.363,1.653 0.426,0.166 10 GND1 1.937,1.823 2.363,1.990 0.426,0.166 10 GND2

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


HINT:

When attempting to reproduce the problem, turning the power switch on (IG) and off repeatedly makes it easier to reproduce the problem. Do not repeatedly turn the power switch on (READY) and off as this will activate a system main relay overheat protection.


PROCEDURE

1.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the A59 inverter with converter assembly connector.


c.

Disconnect the A22 power management control ECU connector.


d.

Measure the resistance according to the value(s) in the table below.

A398184E01
0.417,1.167 0.833,1.417 0.417,0.25 4,1.5 4.417,1.75 0.417,0.25 1.26,1.99 1.521,1.531 false 5.292,2.083 4.979,1.792 false 0.135,0.094 0.448,0.292 0.313,0.198 10 false *a 3.573,0.125 3.885,0.323 0.313,0.198 10 false *b 0.49,1.198 0.802,1.396 0.313,0.198 10 false A59 0.875,2.021 1.375,2.219 0.5,0.198 10 false HSDN 4.083,1.542 4.396,1.74 0.313,0.198 10 false A22 5.333,2.094 5.833,2.292 0.5,0.198 10 false HSDN

Standard Resistance:
Tester Connection Condition Specified Condition
A22-31 (HSDN) or A59-31 (HSDN) - Body ground and other terminals Power switch off 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
*b Rear view of wire harness connector
(to Power Management Control ECU)


e.

Reconnect the A22 power management control ECU connector.


f.

Reconnect the A59 inverter with converter assembly connector.



OK

2.CHECK INVERTER WITH CONVERTER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

2.CHECK INVERTER WITH CONVERTER ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the A59 inverter with converter assembly connector.


c.
U154300E03
1.781,1.26 2.323,1.854 false 1.104,1.198 0.667,1.771 false 2.115,1.865 2.563,2.021 0.448,0.156 10 false HSDN 0.104,0.021 0.26,0.177 0.156,0.156 10 false *a 1.26,1.896 1.531,2.052 0.271,0.156 10 false A59 0.385,1.771 0.833,1.927 0.448,0.156 10 false GND1

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A59-31 (HSDN) - A59-28 (GND1) Power switch off 2.65 to 3.55 kΩ


Text in Illustration
*a Component without harness connected
(Inverter with Converter Assembly)


d.

Reconnect the A59 inverter with converter assembly connector.



OK

NG

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS