The electronic shift lever system is a linkless type that does not use a shift cable.
The shift and select sensors are non-contact type sensors.
The shift lever (shift lock control unit assembly) is a momentary type, which returns to its home position by spring reaction as the driver's hand is released from the shift lever after shifting.
The shift lever (shift lock control unit assembly) contains a shift sensor and a select sensor to detect the shift lever position (Home, R, N, D or B). Because the shift sensor operates using Hall ICs and the select sensor operates using MR ICs, they can accurately detect the shift lever position in a reliable manner. Both sensors contain two detection circuits, a main and a sub circuit.
The shift sensor outputs voltage, which varies between 0 and 5 V in accordance with the vertical movement of the shift lever, to the power management control ECU. The power management control ECU interprets low level voltage input from the shift sensor as the R position, middle level voltage as the home or N position, and high level voltage as the D or B position.
The select sensor outputs voltage, which varies between 0 and 5 V in accordance with the horizontal movement of the shift lever, to the power management control ECU. The power management control ECU interprets low level voltage input from the select sensor as the home or B position, and high level voltage as the R, N, or D position.
The power management control ECU determines the position of the shift lever in accordance with the combination of the signals from the shift sensor and select sensor.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P082B | 575 | Open or GND short in select main sensor circuit | ·
Wire harness or connector ·
Shift lock control unit assembly ·
Power management control ECU |
| P082C | 576 | +B short in select main sensor circuit | |
| P082E | 571 | Open or GND short in shift main sensor circuit | |
| P082F | 572 | +B short in shift main sensor circuit | |
| P181A | 596 | Difference between select main sensor value and select sub sensor value is large | |
| P181B | 595 | Difference between shift main sensor value and shift sub sensor value is large | |
| P182B | 577 | Open or GND short in select sub sensor circuit | |
| P182C | 578 | +B short in select sub sensor circuit | |
| P182E | 573 | Open or GND short in shift sub sensor circuit | |
| P182F | 574 | +B short in shift sub sensor circuit |
When any of DTCs P082E-571, P082F-572, P182E-573 or P182F-574 are output, check Shift Sensor Main and Shift Sensor Sub voltages using the GTS.
| R position
(Main) |
Home or N position
(Main) |
D or B position
(Main) |
R position
(Sub) |
Home or N position
(Sub) |
D or B position
(Sub) |
Trouble Area |
|---|---|---|---|---|---|---|
| 0.3 to 1.8 V | 2.0 to 3.0 V | 3.2 to 4.8 V | 0.3 to 1.8 V | 2.0 to 3.0 V | 3.2 to 4.8 V | Correct shift sensor voltage |
| 0 to 0.3 V | 0 to 0.3 V | 0 to 0.3 V | 0.3 to 1.8 V | 2.0 to 3.0 V | 3.2 to 4.8 V | Open in VCX1 circuit
GND short in VSX1 circuit |
| 0.3 to 1.8 V | 2.0 to 3.0 V | 3.2 to 4.8 V | 0 to 0.3 V | 0 to 0.3 V | 0 to 0.3 V | Open in VCX2 circuit
GND short in VSX2 circuit |
| 4.8 to 5.0 V | 4.8 to 5.0 V | 4.8 to 5.0 V | 0.3 to 1.8 V | 2.0 to 3.0 V | 3.2 to 4.8 V | Open in VSX1 circuit
Open in E2X1 circuit |
| 0.3 to 1.8 V | 2.0 to 3.0 V | 3.2 to 4.8 V | 4.8 to 5.0 V | 4.8 to 5.0 V | 4.8 to 5.0 V | Open in VSX2 circuit
Open in E2X2 circuit |
When any of DTCs P082B-575, P082C-576, P182B-577 or P182C-578 are output, check Shift Sensor Select Main and Shift Sensor Select Sub voltages using the GTS.
| R, N or D Position
Select Main) |
Home or B Position
Select Main) |
R, N or D Position
Select Sub) |
Home or B Position
Select Sub) |
Trouble Area |
|---|---|---|---|---|
| 2.9 to 4.3 V | 1.0 to 1.6 V | 2.9 to 4.3 V | 1.0 to 1.6 V | Correct select sensor voltage |
| 0 to 0.5 V | 0 to 0.5 V | 2.9 to 4.3 V | 1.0 to 1.6 V | Open in VCX3 circuit
Open or GND short in VSX3 circuit |
| 2.9 to 4.3 V | 1.0 to 1.6 V | 0 to 0.5 V | 0 to 0.5 V | Open in VCX4 circuit
Open or GND short in VSX4 circuit |
| 4.9 to 5.0 V | 4.9 to 5.0 V | 2.9 to 4.3 V | 1.0 to 1.6 V | +B short in VSX3 circuit |
| 2.9 to 4.3 V | 1.0 to 1.6 V | 4.9 to 5.0 V | 4.9 to 5.0 V | +B short in VSX4 circuit |
Refer to the wiring diagram for DTC P0AE6-225 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE6-225).
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (IG).
Slowly move the shift lever as follows: N → R → N → D → B
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Shift Sensor Main, Shift Sensor Sub.
Read the Data List.
| Tester Display | Condition | Specified Condition |
|---|---|---|
| Shift Sensor Main | R position | 0.3 to 1.8 V |
| Home or N position | 2.0 to 3.0 V | |
| D or B position | 3.2 to 4.8 V | |
| Shift Sensor Sub | R position | 0.3 to 1.8 V |
| Home or N position | 2.0 to 3.0 V | |
| D or B position | 3.2 to 4.8 V |
Turn the power switch off.
OK
NG
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Shift Sensor Select Main, Shift Sensor Select Sub.
Read the Data List.
| Tester Display | Condition | Specified Condition |
|---|---|---|
| Shift Sensor Select Main | R, N or D Position | 2.9 to 4.3 V |
| Home or B Position | 1.0 to 1.6 V | |
| Shift Sensor Select Sub | R, N or D Position | 2.9 to 4.3 V |
| Home or B Position | 1.0 to 1.6 V |
Turn the power switch off.
OK
NG
NEXT
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read and record the DTCs and freeze frame data.
Clear DTCs and freeze frame data.
Turn the power switch off.
NEXT
Connect the GTS to the DLC3.
Turn the power switch on (IG).
With the brake pedal depressed, slowly move the shift lever as follows to select each shift state: N → R → N → D → B.
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| No DTCs are output. | A |
| P082B-575, P082C-576, P082E-571, P082F-572, P181A-596, P181B-595, P182B-577, P182C-578, P182E-573 or P182F-574 is output again. | B |
Turn the power switch off.
A
B
Disconnect the L5 power management control ECU connector.
Disconnect the L127 shift sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L5-26 (VCX1) - L127-3 (VCX1) | Power switch off | Below 1 Ω |
| L5-25 (VSX1) - L127-1 (VSX1) | Power switch off | Below 1 Ω |
| L5-24 (E2X1) - L127-2 (E2X1) | Power switch off | Below 1 Ω |
| L5-21 (VCX2) - L127-6 (VCX2) | Power switch off | Below 1 Ω |
| L5-22 (VSX2) - L127-4 (VSX2) | Power switch off | Below 1 Ω |
| L5-23 (E2X2) - L127-5 (E2X2) | Power switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L5-26 (VCX1) or L127-3 (VCX1) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| L5-25 (VSX1) or L127-1 (VSX1) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| L5-24 (E2X1) or L127-2 (E2X1) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| L5-21 (VCX2) or L127-6 (VCX2) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| L5-22 (VSX2) or L127-4 (VSX2) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| L5-23 (E2X2) or L127-5 (E2X2) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
| *b | Front view of wire harness connector
(to Shift Sensor) |
As necessary, check that there is no short to power supply wires when performing the above wire harness inspection.
Reconnect the L127 shift sensor connector.
Reconnect the L5 power management control ECU connector.
OK
NG
Disconnect the L127 shift sensor connector.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L127-3 (VCX1) - L127-2 (E2X1) | Power switch on (IG) | 4.5 to 5.5 V |
| L127-6 (VCX2) - L127-5 (E2X2) | Power switch on (IG) | 4.5 to 5.5 V |
| *a | Front view of wire harness connector
(to Shift Sensor) |
Turning the power switch on (IG) with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Reconnect the L127 shift sensor connector.
OK
NG
NEXT
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read and record the DTCs and freeze frame data.
Clear DTCs and freeze frame data.
Turn the power switch off.
NEXT
Connect the GTS to the DLC3.
Turn the power switch on (IG).
With the brake pedal depressed, slowly move the shift lever as follows to select each shift state: N → R → N → D → B.
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| No DTCs are output. | A |
| P082B-575, P082C-576, P082E-571, P082F-572, P181A-596, P181B-595, P182B-577, P182C-578, P182E-573 or P182F-574 is output again. | B |
Turn the power switch off.
A
B
Disconnect the L5 power management control ECU connector.
Disconnect the L126 select sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L5-19 (VCX3) - L126-5 (VCX3) | Power switch off | Below 1 Ω |
| L5-20 (VSX3) - L126-4 (VSX3) | Power switch off | Below 1 Ω |
| L5-17 (VCX4) - L126-2 (VCX4) | Power switch off | Below 1 Ω |
| L5-18 (VSX4) - L126-1 (VSX4) | Power switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L5-19 (VCX3) or L126-5 (VCX3) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| L5-20 (VSX3) or L126-4 (VSX3) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| L5-17 (VCX4) or L126-2 (VCX4) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| L5-18 (VSX4) or L126-1 (VSX4) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| *a | Rear view of wire harness connector:
(to Power Management Control ECU) |
| *b | Front view of wire harness connector:
(to Select Sensor) |
As necessary, check that there is no short to power supply wires when performing the above wire harness inspection.
Reconnect the L126 select sensor connector.
Reconnect the L5 power management control ECU connector.
OK
NG
Disconnect the L126 select sensor connector.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L126-5 (VCX3) - Body ground | Power switch on (IG) | 9 to 14 V |
| L126-2 (VCX4) - Body ground | Power switch on (IG) | 9 to 14 V |
| *a | Front view of wire harness connector:
(to Select Sensor) |
Turning the power switch on (IG) with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Reconnect the L126 select sensor connector.
OK
NG
NEXT
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read and record the DTCs and freeze frame data.
Clear DTCs and freeze frame data.
Turn the power switch off.
NEXT
Connect the GTS to the DLC3.
Turn the power switch on (IG).
With the brake pedal depressed, slowly move the shift lever as follows to select each shift state: N → R → N → D → B.
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| No DTCs are output. | A |
| P082B-575, P082C-576, P082E-571, P082F-572, P181A-596, P181B-595, P182B-577, P182C-578, P182E-573 or P182F-574 is output again. | B |
Turn the power switch off.
A
B