For a description of the inverter (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0D2F-266).
The inverter with converter assembly (MG ECU) controls MG2 based on commands from the hybrid vehicle control ECU. The inverter with converter assembly (MG ECU) monitors communication data and detects malfunctions.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| U0110 | 159 | Error in reception from inverter with converter assembly (MG ECU) via serial communication (out of communication standard) | ·
Wire harness or connector ·
Inverter with converter assembly ·
Generator cable ·
Motor cable ·
Hybrid vehicle transaxle assembly ·
Hybrid vehicle control ECU ·
PCU fuse |
| 656 | Error in reception from inverter with converter assembly (MG ECU) via serial communication (out of communication standard) | ||
| 657 | Error in reception from inverter with converter assembly (MG ECU) via serial communication (no reception) |
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
If any of the DTCs U0110-159, U0110-656, and U0110-657 was set due to incomplete engagement of the connectors, and if the system returns to normal when the power switch is turned on (IG) after clearing the DTCs, DTC P324E-788 will be set. Proceed to troubleshooting without considering DTC P324E-788.
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (IG) and wait for 2 minutes or more.
Remove the PCU fuse from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| PCU fuse terminals | Always | Below 1 Ω |
| *1 | Engine Room Relay Block and Junction Block Assembly |
| *2 | PCU Fuse |
Install the PCU fuse.
OK
NG
NEXT
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| DTC U0110-159, 656 or 657 is output. | A |
| DTC U0110-159, 656 and 657 are not output. | B |
Turn the power switch off.
A
B
A
B
C
A
B
C
OK
NG
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A59 inverter with converter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-28 (GND1) - Body ground | Power switch off | Below 1 Ω |
| A59-27 (GND2) - Body ground | Power switch off | Below 1 Ω |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-10 (+B) - Body ground | Power switch on (IG) | 11 to 14 V |
| A59-9 (+B2) - Body ground | Power switch on (IG) | 11 to 14 V |
Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Reconnect the A59 inverter with converter assembly connector.
OK
NG
Connect an oscilloscope between the hybrid vehicle control ECU terminals specified in the following table.
Turn the power switch on (IG).
Measure the waveform.
| Item | Contents |
|---|---|
| Tester Connection | CH1: A22-33 (CLK+) - L5-6 (E1)
CH2: A22-32 (CLK-) - L5-6 (E1) |
| Equipment Setting | 1V/DIV., 1μs/DIV. |
| Condition | Power switch on (IG) |
| Result | Proceed to |
|---|---|
| The waveform appears as shown in the illustration. | A |
| The waveform differs from the one shown in the illustration. | B |
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
Inspect with the connector connected.
If pulses are generated, the shape of the waveform can be assumed to be normal.
The shape of the waveform may vary according to communication conditions.
Turn the power switch off.
A
B
Connect an oscilloscope between the hybrid vehicle control ECU terminals specified in the following table.
Turn the power switch on (IG).
Measure the waveform.
| Item | Contents |
|---|---|
| Tester Connection | CH1: A22-31 (REQ+) - L5-6 (E1)
CH2: A22-30 (REQ-) - L5-6 (E1) |
| Equipment Setting | 1V/DIV., 1ms/DIV. |
| Condition | Power switch on (IG) |
| Result | Proceed to |
|---|---|
| The waveform appears as shown in the illustration. | A |
| The waveform differs from the one shown in the illustration. | B |
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
Inspect with the connector connected.
If pulses are generated, the shape of the waveform can be assumed to be normal.
The shape of the waveform may vary according to communication conditions.
Turn the power switch off.
A
B
Connect an oscilloscope between the hybrid vehicle control ECU terminals specified in the following table.
Turn the power switch on (IG).
Measure the waveform.
| Item | Contents |
|---|---|
| Tester Connection | CH1: A22-23 (MTH+) - L5-6 (E1)
CH2: A22-22 (MTH-) - L5-6 (E1) |
| Equipment Setting | 1V/DIV., 200μs/DIV. |
| Condition | Power switch on (IG) |
| Result | Proceed to |
|---|---|
| The waveform appears as shown in the illustration. | A |
| The waveform differs from the one shown in the illustration. | B |
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
Inspect with the connector connected.
If pulses are generated, the shape of the waveform can be assumed to be normal.
The shape of the waveform may vary according to communication conditions.
Turn the power switch off.
A
B
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A22 hybrid vehicle control ECU connector.
Disconnect the A59 inverter with converter assembly connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-33 (CLK+) - Body ground | Power switch on (IG) | Below 1 V |
| A22-32 (CLK-) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Rear view of wire harness connector
(to Hybrid Vehicle Control ECU) |
| *b | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Turning the power switch on (IG) with the hybrid vehicle control ECU connector and the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-33 (CLK+) - A59-5 (CLK+) | Power switch off | Below 1 Ω |
| A22-32 (CLK-) - A59-15 (CLK-) | Power switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-33 (CLK+) or A59-5 (CLK+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A22-32 (CLK-) or A59-15 (CLK-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A59 inverter with converter assembly connector.
Reconnect the A22 hybrid vehicle control ECU connector.
OK
NG
Disconnect the A22 hybrid vehicle control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-33 (CLK+) - A32-32 (CLK-) | Power switch off | 80 to 170 Ω |
| *a | Rear view of wire harness connector
(to Hybrid Vehicle Control ECU) |
Reconnect the A22 hybrid vehicle control ECU connector.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A22 hybrid vehicle control ECU connector.
Disconnect the A59 inverter with converter assembly connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-31 (REQ+) - Body ground | Power switch on (IG) | Below 1 V |
| A22-30 (REQ-) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Rear view of wire harness connector
(to Hybrid Vehicle Control ECU) |
| *b | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Turning the power switch on (IG) with the hybrid vehicle control ECU connector and the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-31 (REQ+) - A59-6 (REQ+) | Power switch off | Below 1 Ω |
| A22-30 (REQ-) - A59-16 (REQ-) | Power switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-31 (REQ+) or A59-6 (REQ+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A22-30 (REQ-) or A59-16 (REQ-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A59 inverter with converter assembly connector.
Reconnect the A22 hybrid vehicle control ECU connector.
OK
NG
Disconnect the A22 hybrid vehicle control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-31 (REQ+) - A22-30 (REQ-) | Power switch off | 80 to 170 Ω |
| *a | Rear view of wire harness connector
(to Hybrid Vehicle Control ECU) |
Reconnect the A22 hybrid vehicle control ECU connector.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A22 hybrid vehicle control ECU connector.
Disconnect the A59 inverter with converter assembly connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-23 (MTH+) - Body ground | Power switch on (IG) | Below 1 V |
| A22-22 (MTH-) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Rear view of wire harness connector
(to Hybrid Vehicle Control ECU) |
| *b | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Turning the power switch on (IG) with the hybrid vehicle control ECU connector and the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-23 (MTH+) - A59-7 (MTH+) | Power switch off | Below 1 Ω |
| A22-22 (MTH-) - A59-17 (MTH-) | Power switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-23 (MTH+) or A59-7 (MTH+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A22-22 (MTH-) or A59-17 (MTH-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A59 inverter with converter assembly connector.
Reconnect the A22 hybrid vehicle control ECU connector.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A59 inverter with converter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-23 (MTH+) - A22-22 (MTH-) | Power switch off | 80 to 170 Ω |
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
Reconnect the A59 inverter with converter assembly connector.
OK
NG
Replace the PCU fuse.
| *1 | Engine Room Relay Block and Junction Block Assembly |
| *2 | PCU Fuse |
Turn the power switch on (READY).
Check if there is an open circuit in the PCU fuse in engine room relay block and junction block assembly.
There is no open circuit in the PCU fuse.
If the fuse does not become open again after turning the power switch on (READY), it can be assumed that the previous fuse failed due to age.
Turn the power switch off.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the PCU fuse from the engine room relay block and junction block assembly.
| *1 | Engine Room Relay Block and Junction Block Assembly |
| *2 | PCU Fuse |
Disconnect the A59 inverter with converter assembly connector.
Measure the resistance according to the value(s) in the table below.
| *1 | Engine Room Relay Block and Junction Block Assembly | *2 | PCU Fuse |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-10 (+B) - 2 (PCU fuse terminal) | Power switch off | Below 1 Ω |
| A59-9 (+B2) - 2 (PCU fuse terminal) | Power switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-10 (+B), A59-9 (+B2) or 2 (PCU fuse terminal) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Reconnect the A59 inverter with converter assembly connector.
Install the PCU fuse.
OK
NG
Refer to replace inverter with converter assembly parts (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DTC CHECK / CLEAR).
NEXT
NEXT
A
B
C
OK
NG
A
B
C
OK
NG