The battery smart unit detects the HV battery conditions (voltage, current, and temperature) and the battery cooling fan voltage, and sends the detected signals to the hybrid vehicle control ECU via serial communication. (The hybrid vehicle control ECU does not send signals to the battery smart unit.)
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| U029A | 123 | Serial communication error between the battery smart unit and the hybrid vehicle control ECU (The hybrid vehicle control ECU did not receive signals from the battery smart unit.) (1 trip detection) | ·
Wire harness or connector ·
Hybrid vehicle control ECU ·
Battery smart unit |
Refer to the wiring diagram for DTC P0AFC-123 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0AFC-123).
If the battery cover is removed, install it before turning the power switch on (IG) or (READY). If the power switch is turned on (IG) or (READY) with the battery cover removed, U029A-123 may be stored.
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
After the repair, clear the DTCs, turn the power switch on (IG), wait for 1 minute or more and check for DTCs.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR).
| Result | Proceed to |
|---|---|
| Only U029A-123 is output. | A |
| DTCs other than U029A-123 are also output. | B |
Turn the power switch off.
A
B
(See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L144-1 (B) - L144-4 (GND) | Power switch off | 8.6 V or more |
| L144-5 (IGCT) - L144-4 (GND) | Power switch on (IG) | 8.6 V or more |
| *a | Component with harness connected
(Battery Smart Unit) |
As there might be an intermittent malfunction in the battery voltage sensor power source circuit, inspect the following even if the measured voltage is as specified:
Installation condition of fuse(s) (before removing fuse(s)) (IGCT circuit)
Fuse condition (before and after removing fuse(s)) (IGCT circuit)
Connection condition of connectors (IGCT circuit)
Wire harness condition (IGCT circuit)
Wire harness condition (GND circuit)
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the No. 1 hybrid battery shield sub-assembly.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the L5 hybrid vehicle control ECU connector.
Before disconnecting the connector, push in on the connector body to check that the connector is not loose or disconnected.
Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).
Disconnect the L144 battery smart unit connector.
Before disconnecting the connector, push in on the connector body to check that the connector is not loose or disconnected.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L5-32 (BTH+) - L144-2 (BTH+) | Power switch off | Below 1 Ω |
| L5-33 (BTH-) - L144-3 (BTH-) | Power switch off | Below 1 Ω |
| L144-4 (GND) - Body ground | Power switch off | Below 1 Ω |
| L144-2 (BTH+) - L144-4 (GND) and Body ground | Power switch off | 10 kΩ or higher |
| L144-3 (BTH-) - L144-4 (GND) and Body ground | Power switch off | 10 kΩ or higher |
| *a | Rear view of wire harness connector
(to Hybrid Vehicle Control ECU) |
| *b | Rear view of wire harness connector
(to Battery Smart Unit) |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L5-32 (BTH+) - Body ground | Power switch on (IG) | Below 1 V |
| L5-33 (BTH-) - Body ground | Power switch on (IG) | Below 1 V |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the L144 battery smart unit connector.
Install the No. 1 hybrid battery shield sub-assembly.
Reconnect the L5 hybrid vehicle control ECU connector.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).
Disconnect the L144 battery smart unit connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L144-2 (BTH+) - L144-4 (GND) | Power switch on (IG) | 2.3 to 2.7 V |
| L144-3 (BTH-) - L144-4 (GND) | Power switch on (IG) | 2.3 to 2.7 V |
| *a | Rear view of wire harness connector
(to Battery Smart Unit) |
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L144-2 (BTH+) - L144-3 (BTH-) | Power switch off | 4.4 to 5.4 kΩ |
Resistance becomes 2.0 kΩ or less when there is a short circuit in the hybrid vehicle control ECU.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the L144 battery smart unit connector.
Install the No. 1 hybrid battery shield sub-assembly.
OK
NG