G92Z0
1.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
Inspect SMRB
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| k3-1 (+) - T6-1 (CBI)) | Auxiliary battery voltage is not applied between terminals c6-4 (SMRB) and c6-2 (GND) | 10 kΩ or higher |
| Auxiliary battery voltage is applied between terminals c6-4 (SMRB) and c6-2 (GND) | Below 1 Ω |
| *a | Component without harness connected
(Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| c6-4 (SMRB) - c6-2 (GND) | -40 to 80°C (-40 to 176°F) | 19.0 to 35.5 Ω |
If the result is not as specified, replace the hybrid battery junction block assembly.
Inspect SMRG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| h3-1 (-) - T5-1 (CEI) | Auxiliary battery voltage is not applied between terminals c6-1 (SMRG) and c6-2 (GND) | 10 kΩ or higher |
| Auxiliary battery voltage is applied between terminals c6-1 (SMRG) and c6-2 (GND) | Below 1 Ω |
| *a | Component without harness connected
(Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| c6-1 (SMRG) - c6-2 (GND) | -40 to 80°C (-40 to 176°F) | 19.0 to 35.5 Ω |
If the result is not as specified, replace the hybrid battery junction block assembly.
Inspect SMRP
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| h3-1 (-) - T5-1 (CEI) | Auxiliary battery voltage is not applied between terminals c6-3 (SMRP) and c6-2 (GND) | 10 kΩ or higher |
| Auxiliary battery voltage is applied between terminals c6-3 (SMRP) and c6-2 (GND) | 28.5 to 31.5 Ω |
| *a | Component without harness connected
(Hybrid Battery Junction Block Assembly) |
| *b | Connector (-) |
| *c | Terminal (-) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| c6-3 (SMRP) - c6-2 (GND) | -40 to 80°C (-40 to 176°F) | 112 to 274 Ω |
If the result is not as specified, replace the hybrid battery junction block assembly.