16363
1.INSPECT COOLING FAN MOTOR
Check that the motor operates smoothly when the auxiliary battery is connected to the cooling fan motor connector.
| *1 | Component without harness connected
(to Cooling Fan Motor) |
Clamp the 400 A probe of an ammeter over the M+ wire of the cooling fan motor.
Measure the current while the motor is operating.
| Item | Condition | Specified Condition |
|---|---|---|
| Cooling fan motor | 20°C (68°F)
at 12 V |
7.4 to 11.4 A |
If the result is not as specified, replace the cooling fan motor.
16363A
2.INSPECT NO. 2 COOLING FAN MOTOR
Check that the motor operates smoothly when the auxiliary battery is connected to the No. 2 cooling fan motor connector.
| *1 | Component without harness connected
(to No. 2 Cooling Fan Motor) |
Clamp the 400 A probe of an ammeter over the M+ wire of the No. 2 cooling fan motor.
Measure the current while the motor is operating.
| Item | Condition | Specified Condition |
|---|---|---|
| No. 2 cooling fan motor | 20°C (68°F)
at 12 V |
4.7 to 8.7 A |
If the result is not as specified, replace the No. 2 cooling fan motor.