Home › Engine / Hybrid System › 2ZR-FXE (COOLING) › RELAY
RM2070E _51 Engine / Hybrid System _061911 2ZR-FXE COOLING _0301630 RELAY G

2ZR-FXE COOLING  RELAY  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 85927 1.INSPECT FAN NO. 1 RELAY

a.
A252086E05
1.823,0.188 1.938,0.188 1.938,0.188 2.031,0.563 false 2.823,0.188 2.708,0.188 2.708,0.188 2.625,0.563 false 2.542,1.104 2.938,1.104 false 2.542,1.594 2.948,1.594 false 2.979,1.51 3.125,1.688 0.146,0.177 10 3 0.198,0.74 0.344,0.917 0.146,0.177 10 3 2.875,0.104 3.021,0.281 0.146,0.177 10 2 1.229,1.281 1.375,1.458 0.146,0.177 10 2 0.198,1.271 0.344,1.448 0.146,0.177 10 1 1.729,0.094 1.875,0.271 0.146,0.177 10 1 2.969,1.01 3.115,1.188 0.146,0.177 10 5 1.229,0.75 1.375,0.927 0.146,0.177 10 5

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Auxiliary battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Auxiliary battery voltage is applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the fan No. 1 relay.


Hide 85927A 2.INSPECT FAN NO. 2 RELAY

a.
A159206E29
2.531,1.125 2.885,1.125 false 2.521,1.625 2.885,1.625 false 1.802,0.177 1.938,0.177 1.938,0.177 2.021,0.573 false 2.542,0.167 2.417,0.167 2.417,0.167 2.323,0.563 false 2.656,0.656 3.021,0.656 false 2.927,1.542 3.083,1.729 0.156,0.188 10 false 3 1.156,0.927 1.313,1.115 0.156,0.188 10 false 3 3.052,0.573 3.208,0.76 0.156,0.188 10 false 2 1.167,1.313 1.323,1.5 0.156,0.188 10 false 2 1.708,0.083 1.865,0.271 0.156,0.188 10 false 1 0.208,1.333 0.365,1.521 0.156,0.188 10 false 1 2.917,1.052 3.073,1.24 0.156,0.188 10 false 5 0.208,0.927 0.365,1.115 0.156,0.188 10 false 5 2.615,0.073 2.729,0.25 0.115,0.177 10 false 4 0.698,0.406 0.854,0.594 0.156,0.188 10 false 4

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 4 Auxiliary battery voltage is not applied between terminals 1 and 2 Below 1 Ω
3 - 4 Auxiliary battery voltage is applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Auxiliary battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Auxiliary battery voltage is applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the fan No. 2 relay.


Hide 85927B 3.INSPECT FAN NO. 3 RELAY

a.
A252086E05
1.823,0.188 1.938,0.188 1.938,0.188 2.031,0.563 false 2.823,0.188 2.708,0.188 2.708,0.188 2.625,0.563 false 2.542,1.104 2.938,1.104 false 2.542,1.594 2.948,1.594 false 2.979,1.51 3.125,1.688 0.146,0.177 10 3 0.198,0.74 0.344,0.917 0.146,0.177 10 3 2.875,0.104 3.021,0.281 0.146,0.177 10 2 1.229,1.281 1.375,1.458 0.146,0.177 10 2 0.198,1.271 0.344,1.448 0.146,0.177 10 1 1.729,0.094 1.875,0.271 0.146,0.177 10 1 2.969,1.01 3.115,1.188 0.146,0.177 10 5 1.229,0.75 1.375,0.927 0.146,0.177 10 5

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Auxiliary battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Auxiliary battery voltage is applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the fan No. 3 relay.