1.INSPECT POWER SWITCH
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(Power Switch) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 5 (SS1) - 6 (AGND)
1 (SS2) - 6 (AGND) |
Not pushed | 10 kΩ or higher |
| Pushed | Below 1 Ω |
If the result is not as specified, replace the power switch.
Apply auxiliary battery voltage between the terminals of the power switch, and check the illumination condition of the power switch indicator light.
| Condition | Specified Condition |
|---|---|
| Auxiliary battery positive (+) → Terminal 9 (SWIL)
Auxiliary battery negative (-) → Terminal 6 (AGND) |
Illuminates |
If the positive (+) lead and the negative (-) lead are incorrectly connected, the power switch indicator light will not illuminate.
If the voltage is too low, the power switch indicator light will not illuminate.