Home › Drivetrain › P410 (HYBRID TRANSMISSION / TRANSAXLE) › ELECTRONIC SHIFT LEVER SYSTEM
RM2070E _52 Drivetrain _061915 P410 HYBRID TRANSMISSION / TRANSAXLE _0301645 ELECTRONIC SHIFT LEVER SYSTEM U

P410 HYBRID TRANSMISSION / TRANSAXLE  ELECTRONIC SHIFT LEVER SYSTEM  TERMINALS OF ECU  


TRANSMISSION CONTROL ECU INSPECTION


U191137E02
2.646,0.135 2.917,0.292 0.271,0.156 10 false A23 4.198,0.135 4.469,0.292 0.271,0.156 10 false A24

HINT:

Inspect the connectors from the back while the connector is connected.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
A23-1 (MWA) - A24-6 (E01) W - W-B Parking lock motor Engine stopped (hybrid system stopped), power switch on (IG) 9 to 14 V
A23-2 (MVA) - A24-6 (E01) R - W-B Parking lock motor Engine stopped (hybrid system stopped), power switch on (IG) 9 to 14 V
A23-5 (MUA) - A24-6 (E01) B - W-B Parking lock motor Engine stopped (hybrid system stopped), power switch on (IG) 9 to 14 V
A23-7 (VC) - A23-19 (E2) G - P Power source (Rotation angle sensor) Engine stopped (hybrid system stopped), power switch on (IG) 4.5 to 5.5 V
A23-8 (RB) - A23-19 (E2) GR - P Rotation angle sensor signal Power switch off → Power switch on (IG) 0 to 1.5 V ←→ 4 to 5.5 V
Power switch on (IG)
Changing from park (P) to neutral (N), or neutral (N) to park (P).
Pulse generation
(see waveform 1)
A23-15 (BATT) - A24-1 (E1) SB - BR Power source (RAM) Always 9 to 14 V
A23-16 (+B) - A24-1 (E1) L - BR Power source Engine stopped (hybrid system stopped), power switch on (IG) 9 to 14 V
A23-17 (RA) - A23-19 (E2) LG - P Rotation angle sensor signal Power switch off → Power switch on (IG) 0 to 1.5 V ←→ 4 to 5.5 V
Power switch on (IG)
Changing from park (P) to neutral (N), or neutral (N) to park (P).
Pulse generation
(see waveform 1)
A23-19 (E2) - Body ground P - Body ground Rotation angle sensor ground Always Below 1 Ω
A23-20 (IND) - A24-1 (E1) R - BR P position switch indicator light Park (P) not selected → Park (P) selected [P position switch (transmission shift main switch) pushed to select park (P)] 9 to 14 V → 0 to 1.5 V
A23-23 (BMA) - A24-1 (E1) B - BR P CON MTR relay (transaxle parking lock control relay) Engine stopped (hybrid system stopped), power switch on (IG) 9 to 14 V
A24-1 (E1) - Body ground BR - Body ground Ground Always Below 1 Ω
A24-5 (E02) - Body ground W-B - Body ground Ground Always Below 1 Ω
A24-6 (E01) - Body ground W-B - Body ground Ground Always Below 1 Ω
A24-15 (CA1L) - A24-1 (E1) BR - BR CAN communication Power switch on (IG) Pulse generation
(see waveform 2)
A24-16 (CA1H) - A24-1 (E1) Y - BR CAN communication Power switch on (IG) Pulse generation
(see waveform 2)
A24-22 (PCON) - A24-1 (E1) LG - BR Transmission control communication bus Engine stopped (hybrid system stopped), power switch on (IG) Pulse generation
(see waveform 3)
A24-23 (PPOS) - A24-1 (E1) W - BR Transmission control communication bus Engine stopped (hybrid system stopped), power switch on (IG) Pulse generation
(see waveform 3)
A24-24 (LIN) L LIN communication - -


Oscilloscope waveforms


HINT:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


a.
C231275E05
2.75,1.021 3.198,1.208 0.448,0.188 10 GND

Waveform 1 (Rotation angle sensor signal)

Item Contents
Terminal A23-17 (RA) - A23-19 (E2)
A23-8 (RB) - A23-19 (E2)
Equipment setting 2 V/DIV., 100 msec./DIV.
Condition Power switch on (IG)
Changing from park (P) to neutral (N), or neutral (N) to park (P).

HINT:
·

When changing from park (P) to neutral (N), or neutral (N) to park (P) with the power switch on (IG), a waveform will be generated for up to 0.5 seconds.

·

The waveform shown is for reference only.




b.
A379394E01
2.927,1.198 3.313,1.583 0.385,0.385 10 false GND (CH1) 2.927,1.583 3.313,1.99 0.385,0.406 10 false GND (CH2) 0.333,0.719 0.792,0.917 0.458,0.198 10 false CH1 0.354,1.344 0.813,1.542 0.458,0.198 10 false CH2

Waveform 2 (CAN communication signal)

Item Contents
Terminal CH1: A24-16 (CA1H) - A24-1 (E1)
CH2: A24-15 (CA1L) - A24-1 (E1)
Equipment setting 1 V/DIV., 50 μs/DIV.
Condition Power switch on (IG)


c.
C351778E02
0.167,0.854 0.552,1.083 0.385,0.229 10 false CH1 0.188,1.469 0.573,1.698 0.385,0.229 10 false CH2 2.844,1.01 3.229,1.24 0.385,0.229 10 false GND 2.844,1.573 3.229,1.802 0.385,0.229 10 false GND

Waveform 3 (Transmission control communication signal)

Item Contents
Terminal CH1: A24-22 (PCON) - A24-1 (E1)
CH2: A24-23 (PPOS) - A24-1 (E1)
Equipment setting 10 V/DIV., 10 ms/DIV.
Condition Engine stopped (hybrid system stopped), power switch on (IG)