Home › Power Source / Network › POWER DISTRIBUTION › INTEGRATION RELAY › 2012.03–2013.08
RM2070E _57 Power Source / Network _061935 POWER DISTRIBUTION _0301752 INTEGRATION RELAY A

POWER DISTRIBUTION  INTEGRATION RELAY  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


Hide 7.DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).


Hide 82662A 8.REMOVE NO. 1 RELAY BLOCK COVER

a.
E190794

Disengage the 3 claws and remove the No. 1 relay block cover as shown in the illustration.


Hide 82641 9.REMOVE NO. 1 INTEGRATION RELAY

a.
E190796

Disengage the 2 claws and separate the No. 1 integration relay as shown in the illustration.


b.
E190798

Disconnect the 3 connectors to remove the No. 1 integration relay.