The room temperature sensor (cooler thermistor) is installed in the instrument panel. It detects the cabin temperature to control air conditioning AUTO mode. The resistance of the room temperature sensor (cooler thermistor) changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the room temperature sensor (cooler thermistor) and reads voltage changes as the resistance of the room temperature sensor (cooler thermistor) changes. This sensor also sends appropriate signals to the air conditioning amplifier assembly.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1411/11 | Open or short in room temperature sensor (cooler thermistor) circuit | ·
Room temperature sensor (cooler thermistor) ·
Harness or connector between room temperature sensor (cooler thermistor) and air conditioning amplifier assembly ·
Air conditioning amplifier assembly |
If the cabin temperature is approximately -18.6°C (-1.48°F) or lower, DTC B1411/11 may be output even though the system is normal.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Room Temperature Sensor | Room temperature sensor (cooler thermistor) /
Min.: -6.50°C (20.3°F) Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | - |
The display is as specified in the Normal Condition column.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| OK (When troubleshooting according to the DTC) | C |
A
B
(See pageVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>PROBLEM SYMPTOMS TABLE)
C
Remove the room temperature sensor (cooler thermistor) (See page Vehicle Interior>HEATING / AIR CONDITIONING>ROOM TEMPERATURE SENSOR>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 10°C (50°F) | 3.00 to 3.73 kΩ |
| 1 - 2 | 15°C (59°F) | 2.45 to 2.88 kΩ |
| 1 - 2 | 20°C (68°F) | 1.95 to 2.30 kΩ |
| 1 - 2 | 25°C (77°F) | 1.60 to 1.80 kΩ |
| 1 - 2 | 30°C (86°F) | 1.28 to 1.47 kΩ |
| 1 - 2 | 35°C (95°F) | 1.00 to 1.22 kΩ |
| 1 - 2 | 40°C (104°F) | 0.80 to 1.00 kΩ |
| 1 - 2 | 45°C (113°F) | 0.65 to 0.85 kΩ |
| 1 - 2 | 50°C (122°F) | 0.50 to 0.70 kΩ |
| 1 - 2 | 55°C (131°F) | 0.44 to 0.60 kΩ |
| 1 - 2 | 60°C (140°F) | 0.36 to 0.50 kΩ |
Hold the sensor only by its connector. Touching the sensor may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (see the graph).
| *a | Component without harness connected
(Room Temperature Sensor (Cooler Thermistor)) |
| *b | Sensing Portion |
| *c | Resistance (kΩ) |
| *d | Allowable Range |
| *e | Temperature (°C (°F)) |
OK
NG
Disconnect the L17 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L17-29 (TR) - L44-1 | Always | Below 1 Ω |
| L17-34 (SG-1) - L44-2 | Always | Below 1 Ω |
| L17-29 (TR) - Body ground | Always | 10 kΩ or higher |
| L17-34 (SG-1) - Body ground | Always | 10 kΩ or higher |
OK
NG