Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › 2012.03–2017.12
RM2070E _58 Vehicle Interior _061946 HEATING / AIR CONDITIONING _0301837 AIR CONDITIONING SYSTEM C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  B1412/12  Ambient Temperature Sensor Circuit  


DESCRIPTION

The ambient temperature sensor (thermistor assembly) is installed in front of the condenser. It detects the ambient temperature to control air conditioning AUTO mode. This sensor is connected to the air conditioning amplifier assembly and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the ambient temperature sensor (thermistor assembly) changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the ambient temperature sensor (thermistor assembly) and reads voltage changes as the resistance of the ambient temperature sensor (thermistor assembly) changes.

DTC No. DTC Detection Condition Trouble Area
B1412/12 Open or short in ambient temperature sensor (thermistor assembly) circuit
·

Ambient temperature sensor (thermistor assembly)

·

Harness or connector between ambient temperature sensor (thermistor assembly) sensor and air conditioning amplifier assembly

·

Air conditioning amplifier assembly



WIRING DIAGRAM

E229250E14
2.616,0.635 2.714,0.810 0.097,0.174 10 1 2.616,1.399 2.714,1.573 0.097,0.174 10 2 4.783,0.435 4.878,0.610 0.095,0.174 10 5 4.706,1.399 4.877,1.573 0.172,0.174 10 13 5.006,0.523 5.334,0.697 0.329,0.174 10 TAM 5.006,1.476 5.390,1.650 0.384,0.174 10 SG-2 0.456,0.828 0.782,1.002 0.326,0.174 10 A4 0.456,0.987 2.398,1.319 1.942,0.332 10 Ambient Temperature Sensor (Thermistor Assembly) 4.654,1.846 4.930,2.020 0.276,0.174 10 L17 4.654,2.005 6.276,2.337 1.622,0.332 10 Air Conditioning Amplifier Assembly

CAUTION / NOTICE / HINT

HINT:

If the ambient temperature is approximately -52.9°C (-63.22°F) or lower, DTC B1412/12 may be output even though the system is normal.


PROCEDURE

1.READ VALUE USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Data List.


e.

Check the value(s) by referring to the table below.

Air Conditioner
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Ambient Temp Sensor Ambient temperature sensor (thermistor assembly) /
Min: -23.30°C (-9.94°F)
Max: 65.95°C (150.71°F)
Actual ambient temperature displayed -

OK:

The display is as specified in the Normal Condition column.


Result:
Result Proceed to
NG A
OK (When troubleshooting according to Problem Symptoms Table) B
OK (When troubleshooting according to the DTC) C




A

2.INSPECT AMBIENT TEMPERATURE SENSOR (THERMISTOR ASSEMBLY)

B

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

C

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

2.INSPECT AMBIENT TEMPERATURE SENSOR (THERMISTOR ASSEMBLY)
a.

Remove the ambient temperature sensor (thermistor assembly) (See page Vehicle Interior>HEATING / AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>REMOVAL).

E319179E01
2.552,0.5 2.708,0.5 2.708,0.5 3.115,1.438 false 5.479,0.792 5.344,0.792 5.344,0.792 5.094,1.448 false 6.552,2.5 6.969,2.792 0.417,0.292 10 false (140) 6.625,2.344 7.052,2.792 0.427,0.448 10 false 60 6.198,2.344 6.625,2.792 0.427,0.448 10 false 50 5.729,2.344 6.156,2.792 0.427,0.448 10 false 40 5.271,2.344 5.698,2.792 0.427,0.448 10 false 30 4.813,2.344 5.24,2.792 0.427,0.448 10 false 20 4.365,2.344 4.792,2.792 0.427,0.448 10 false 10 6.135,2.5 6.552,2.792 0.417,0.292 10 false (122) 5.667,2.5 6.083,2.792 0.417,0.292 10 false (104) 5.24,2.5 5.656,2.792 0.417,0.292 10 false (86) 4.781,2.5 5.198,2.792 0.417,0.292 10 false (68) 4.344,2.5 4.76,2.792 0.417,0.292 10 false (50) 6.927,2.354 7.156,2.594 0.229,0.24 10 false *e 5.552,0.708 5.781,0.948 0.229,0.24 10 false *d 4.094,0.146 4.323,0.385 0.229,0.24 10 false *c 4.135,0.438 7.156,0.729 3.021,0.292 10 false 4.0 4.135,0.656 7.156,0.948 3.021,0.292 10 false 3.5 4.135,0.875 7.156,1.167 3.021,0.292 10 false 3.0 4.135,1.104 7.156,1.396 3.021,0.292 10 false 2.5 4.135,1.323 7.156,1.615 3.021,0.292 10 false 2.0 4.135,1.563 7.156,1.854 3.021,0.292 10 false 1.5 4.135,1.792 7.156,2.083 3.021,0.292 10 false 1.0 4.135,2.021 7.156,2.313 3.021,0.292 10 false 0.5 4.135,2.24 7.156,2.531 3.021,0.292 10 false 0.0 2.385,0.427 2.615,0.667 0.229,0.24 10 false *b 0.24,0.177 0.469,0.417 0.229,0.24 10 false *a


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
1 - 2 15°C (59°F) 2.45 to 2.88 kΩ
1 - 2 20°C (68°F) 1.95 to 2.30 kΩ
1 - 2 25°C (77°F) 1.60 to 1.80 kΩ
1 - 2 30°C (86°F) 1.28 to 1.47 kΩ
1 - 2 35°C (95°F) 1.00 to 1.22 kΩ
1 - 2 40°C (104°F) 0.80 to 1.00 kΩ
1 - 2 45°C (113°F) 0.65 to 0.85 kΩ
1 - 2 50°C (122°F) 0.50 to 0.70 kΩ
1 - 2 55°C (131°F) 0.44 to 0.60 kΩ
1 - 2 60°C (140°F) 0.36 to 0.50 kΩ


NOTICE:
·

Hold the sensor only by its connector. Touching the sensor may change the resistance value.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).


Text in Illustration
*a Component without harness connected
(Ambient Temperature Sensor (Thermistor Assembly))
*b Sensing Portion
*c Resistance (kΩ)
*d Allowable Range
*e Temperature (°C (°F))



OK

3.CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR (THERMISTOR ASSEMBLY) - AIR CONDITIONING AMPLIFIER)

NG

REPLACE AMBIENT TEMPERATURE SENSOR (THERMISTOR ASSEMBLY)

3.CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR (THERMISTOR ASSEMBLY) - AIR CONDITIONING AMPLIFIER)
a.

Disconnect the L17 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
L17-5 (TAM) - A4-1 Always Below 1 Ω
L17-13 (SG-2) - A4-2 Always Below 1 Ω
L17-5 (TAM) - Body ground Always 10 kΩ or higher
L17-13 (SG-2) - Body ground Always 10 kΩ or higher




OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR