HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  B1423/23  Pressure Sensor Circuit  


DESCRIPTION

This DTC is stored when refrigerant pressure on the high pressure side is extremely low (0.176 MPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3.025 MPa (30.8 kgf/cm2, 439 psi) or more). The air conditioning pressure sensor is installed on the high pressure line. It detects refrigerant pressure to output a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics to control the compressor.

DTC No. DTC Detection Condition Trouble Area
B1423/23
·

Open or short in pressure sensor circuit

·

Refrigerant pressure on the high pressure line is extremely low (0.176 MPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3.025 MPa (30.8 kgf/cm2, 439 psi) or more).


·

Air conditioning pressure sensor

·

Harness or connector between air conditioning pressure sensor and air conditioning amplifier assembly

·

Air conditioning amplifier assembly

·

Expansion valve (blocked, stuck)

·

Condenser assembly (blocked, deterioration of cooling capacity due to dirt)

·

Cooler dryer (moisture in the refrigerant cycle cannot be absorbed)

·

Cooling fan system (condenser cannot be cooled down)

·

A/C system (leaks, blocked)



WIRING DIAGRAM

E229252E17
2.231,1.994 2.329,2.168 0.097,0.174 10 1 2.231,1.041 2.329,1.216 0.097,0.174 10 2 4.853,1.041 4.948,1.216 0.095,0.174 10 9 4.776,1.994 4.947,2.168 0.172,0.174 10 13 1.887,1.142 2.098,1.317 0.211,0.174 10 PR 1.304,3.933 2.538,4.262 1.234,0.329 10 Air Conditioning Pressure Sensor 1.304,3.774 1.588,3.949 0.285,0.174 10 A31 5.08,2.088 5.423,2.262 0.343,0.174 10 SG-2 5.08,3.044 5.423,3.218 0.343,0.174 10 S5-3 4.647,3.751 4.940,3.925 0.294,0.174 10 L17 4.647,3.909 6.399,4.241 1.752,0.332 10 Air Conditioning Amplifier Assembly 2.231,2.948 2.329,3.122 0.097,0.174 10 3 2.002,2.077 2.099,2.252 0.097,0.174 10 - 1.998,3.046 2.099,3.220 0.101,0.174 10 + 4.776,2.948 4.947,3.122 0.172,0.174 10 10 5.08,1.135 5.409,1.310 0.329,0.174 10 PRE

PROCEDURE

1.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (POWER SOURCE CIRCUIT)
a.

Disconnect the A31 air conditioning pressure sensor connector.


b.
U155085E02
1.896,1.563 2.188,1.854 false 0.167,0.083 0.354,0.271 0.188,0.188 10 false *a 1.563,0.438 1.885,0.604 0.323,0.167 10 false A31 2.229,1.823 2.333,1.99 0.104,0.167 10 false +

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A31-3 (+) - Body ground Power switch on (IG) 4.75 to 5.25 V


Text in Illustration
*a Front view of wire harness connector
(to Air Conditioning Pressure Sensor)



OK

2.CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)

NG

5.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - A/C PRESSURE SENSOR)
2.CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)
a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A31-1 (-) - Body ground Always Below 1 Ω




OK

3.INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - A/C PRESSURE SENSOR)
3.INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.

Reconnect the A31 air conditioning pressure sensor connector.


b.
U155070E02
2.365,1.604 2.094,0.854 false 1.667,0.188 1.938,0.354 0.271,0.167 10 false L17 2.219,1.625 2.552,1.792 0.333,0.167 10 false PRE 0.146,0.094 0.313,0.26 0.167,0.167 10 false *a

Remove the air conditioning amplifier assembly with the connectors still connected.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
L17-9 (PRE) - Body ground Power switch on (IG)
(A/C switch: off)
0.70 to 4.69 V


HINT:

If the voltage is not as specified, there may be a malfunction in the air conditioning amplifier assembly, A/C pressure sensor or wire harness. It is also possible that the amount of refrigerant may not be appropriate.


Text in Illustration
*a Component with harness connected
(Air Conditioning Amplifier Assembly)



OK

4.INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - A/C PRESSURE SENSOR)
4.INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.

Turn the power switch on (READY).


b.

Measure the voltage when the following conditions are met:

Item Condition
Vehicle Doors Fully open
Compressor speed 5200 rpm
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch On
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:
·

If refrigerant pressure in the high pressure line becomes extremely high during the inspection (if the voltage exceeds 4.69 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe function operates.

·

It is necessary to measure the voltage over a period of time (approximately 10 minutes) because the problem symptom may recur after a while.



HINT:

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to signals from the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


i.
U155070E02
2.365,1.604 2.094,0.854 false 1.667,0.188 1.938,0.354 0.271,0.167 10 false L17 2.219,1.625 2.552,1.792 0.333,0.167 10 false PRE 0.146,0.094 0.313,0.26 0.167,0.167 10 false *a

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
L17-9 (PRE) - Body ground Power switch on (IG)
(A/C: on)
0.70 to 4.69 V


Result:
Result Proceed to
OK (When troubleshooting according to the DTC) A
OK (When troubleshooting according to Problem Symptoms Table) B
NG C


Text in Illustration
*a Component with harness connected
(Air Conditioning Amplifier Assembly)




A

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

B

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

C

13.INSPECT COOLING FAN SYSTEM
5.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - A/C PRESSURE SENSOR)
a.

Disconnect the L17 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A31-3 (+) - L17-10 (S5-3) Always Below 1 Ω
L17-10 (S5-3) - Body ground Always 10 kΩ or higher




OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - A/C PRESSURE SENSOR)
a.

Disconnect the L17 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A31-1 (-) - L17-13 (SG-2) Always Below 1 Ω
L17-13 (SG-2) - Body ground Always 10 kΩ or higher




OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - A/C PRESSURE SENSOR)
a.

Disconnect the L17 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A31-2 (PR) - L17-9 (PRE) Always Below 1 Ω
A31-2 (PR) - Body ground Always 10 kΩ or higher




OK

8.CHECK FOR A/C SYSTEM LEAK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.CHECK FOR A/C SYSTEM LEAK
a.

Install the manifold gauge set.


b.

Recover the refrigerant from the A/C system using a refrigerant recovery unit.


c.

Evacuate the A/C system and check that vacuum can be maintained.

OK:

Vacuum can be maintained in the A/C system.


HINT:

If vacuum cannot be maintained in the A/C system, there may be a refrigerant leak. In this case, it is necessary to repair or replace the leaking part of the A/C system.




OK

9.CHARGE REFRIGERANT

NG

12.REPAIR A/C SYSTEM LEAK
9.CHARGE REFRIGERANT

NEXT

10.RECHECK FOR DTC
10.RECHECK FOR DTC
a.

Turn the power switch on (READY).


b.

Recheck for the DTC when the following conditions are met:

Item Condition
Vehicle Doors Fully open
Compressor Speed 5200 rpm
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch On
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:

If refrigerant pressure in the high pressure line is excessive, this DTC will be stored. Therefore, it is necessary to measure the voltage over a period of time (approximately 10 minutes) because this DTC may be stored after the A/C has been operating for a while.


HINT:

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to signals from the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


Result:
Result Proceed to
DTC B1423/23 is output A
DTC B1423/23 is not output B


NOTICE:

If the DTC was stored due to an insufficient or excessive amount of refrigerant, the problem may have been solved after performing the previous step. However, the root cause of insufficient refrigerant may be refrigerant leaks. The root cause of excessive refrigerant may be adding refrigerant when the level was insufficient. Therefore, identify and repair any refrigerant leaks as necessary.




A

11.INSPECT AIR CONDITIONING PRESSURE SENSOR

B

END

11.INSPECT AIR CONDITIONING PRESSURE SENSOR
a.

Install the manifold gauge set.


b.

Reconnect the air conditioning pressure sensor connector.


c.

Turn the power switch on (IG).


d.
U155071E02
2.365,1.604 2.094,0.854 false 1.542,1.604 1.813,0.854 false 1.656,0.208 1.99,0.406 0.333,0.198 10 false L17 2.219,1.625 2.552,1.792 0.333,0.167 10 false PRE 0.146,0.094 0.313,0.26 0.167,0.167 10 false *a 1.333,1.625 1.698,1.792 0.365,0.167 10 false SG-2

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
L17-9 (PRE) - L17-13 (SG-2) Refrigerant pressure:
Normal pressure (0.176 to 3.065 MPa [26 to 439 psi])
0.70 to 4.69 V


HINT:

The A/C pressure sensor power source voltage is 5 V.


Text in Illustration
*a Component with harness connected
(Air Conditioning Amplifier Assembly)



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

19.REPLACE AIR CONDITIONING PRESSURE SENSOR
12.REPAIR A/C SYSTEM LEAK

b.

Repair the identified area of the A/C system.


c.

Evacuate the A/C system.


Result:
Result Proceed to
NEXT (for R-134a) A
NEXT (for R-1234yf) B



A

B

13.INSPECT COOLING FAN SYSTEM
a.

Check that the cooling fan(s) operates normally.

HINT:

Refer to Cooling Fan Circuit (See page Engine / Hybrid System>2ZR-FXE (COOLING)>COOLING FAN SYSTEM>ON-VEHICLE INSPECTION).




OK

14.CHARGE REFRIGERANT

NG

REPAIR COOLING FAN SYSTEM

14.CHARGE REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the A/C system.


c.

Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFC-134a(R134a))>REPLACEMENT(for R-134a), See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT (for HFO-1234yf(R1234yf))>REPLACEMENT(for R-1234yf)).

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for DTCs.




NEXT

15.RECHECK FOR DTC
15.RECHECK FOR DTC
a.

Turn the power switch on (READY).


b.

Recheck for the DTC when the following conditions are met:

Item Condition
Vehicle Doors Fully open
Compressor Speed 5200 rpm
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch On
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:

If refrigerant pressure in the high pressure line is excessive, this DTC will be stored. Therefore, it is necessary to measure the voltage over a period of time (approximately 10 minutes) because DTC may be stored after the A/C has been operating for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to signals from the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTC. If the DTC is not output, it indicates that the cooler dryer in the condenser is not able to absorb moisture in the refrigerant. In this case, to complete the repair, it is necessary to replace the cooler dryer.



Result:
Result Proceed to
DTC B1423/23 is output A
DTC B1423/23 is not output B




A

16.REPLACE EXPANSION VALVE

B

16.REPLACE EXPANSION VALVE
a.

Replace the expansion valve with a new or known good one (See page Vehicle Interior>HEATING / AIR CONDITIONING>COOLER EXPANSION VALVE>REMOVAL).

HINT:

Replace the expansion valve with a new or known good one because the expansion valve is either stuck or clogged.




NEXT

17.CHARGE REFRIGERANT
17.CHARGE REFRIGERANT

NEXT

18.RECHECK FOR DTC
18.RECHECK FOR DTC
a.

Turn the power switch on (READY).


b.

Recheck for the DTC when the following conditions are met:

Item Condition
Vehicle Doors Fully open
Compressor Speed 5200 rpm
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch On
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:

If refrigerant pressure in the high pressure line is excessive, this DTC will be stored. Therefore, it is necessary to measure the voltage over a period of time (approximately 10 minutes) because this DTC may be stored after the A/C has been operating for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to signals from the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant pressure is not normal after replacing the expansion valve with a new or known good one, the condenser or pipes may be clogged with dirt, dust or other contaminants. In this case, clean or replace the condenser or pipes.



Result:
Result Proceed to
DTC B1423/23 is not output A
DTC B1423/23 is output B




A

END

B

19.REPLACE AIR CONDITIONING PRESSURE SENSOR
a.

Replace the air conditioning pressure sensor (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING PRESSURE SENSOR>REMOVAL).

HINT:

Since the air conditioning pressure sensor cannot be inspected while it is removed from the vehicle, replace the air conditioner pressure sensor with a new or known good one and check that the condition returns to normal.




NEXT

20.RECHECK FOR DTC
20.RECHECK FOR DTC
a.

Turn the power switch on (READY).


b.

Recheck for the DTC when the following conditions are met:

Item Condition
Vehicle Doors Fully open
Compressor Speed 5200 rpm
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch On
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:

If refrigerant pressure in the high pressure line is excessive, this DTC will be stored. Therefore, it is necessary to measure the voltage over a period of time (approximately 10 minutes) because this DTC may be stored after the A/C has been operating for a while.


HINT:

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to signals from the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


Result:
Result Proceed to
DTC B1423/23 is not output A
DTC B1423/23 is output B




A

END

B

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY