Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM
RM2070E _58 Vehicle Interior _061946 HEATING / AIR CONDITIONING _0301837 AIR CONDITIONING SYSTEM J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  Blower Motor Circuit  


DESCRIPTION

The blower motor with fan sub-assembly is operated by signals from the air conditioning amplifier assembly. Blower motor speed signals are transmitted in accordance with changes in the duty ratio.

WIRING DIAGRAM

E230744E06
3.435,0.517 4.841,0.718 1.406,0.201 10 from Auxiliary Battery 2.463,0.657 2.784,0.850 0.321,0.193 10 HTR 2.027,1.217 2.238,1.429 0.211,0.211 10 1 1.771,0.475 1.986,0.637 0.215,0.163 10 +B 1.807,0.88 1.986,1.068 0.179,0.188 10 SI 2.027,0.814 2.201,1.026 0.174,0.211 10 2 0.53,1.689 0.833,1.856 0.303,0.167 10 L33 0.53,1.857 2.410,2.208 1.880,0.351 10 Front Blower Motor with Fan Sub-assembly 1.631,1.299 1.985,1.478 0.354,0.178 10 GND 5.204,1.299 5.558,1.478 0.354,0.178 10 GND 2.027,0.416 2.192,0.637 0.165,0.221 10 3 4.971,0.814 5.170,0.974 0.199,0.159 10 23 4.971,1.217 5.170,1.376 0.199,0.159 10 14 5.204,0.892 5.582,1.117 0.378,0.225 10 BLW 4.929,1.698 5.298,1.882 0.369,0.184 10 L17 4.929,1.857 6.534,2.219 1.605,0.362 10 Air Conditioning Amplifier Assembly

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


PROCEDURE

1.PERFORM ACTIVE TEST USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Check the operation by referring to the table below.


Air Conditioner
Tester Display Test Part Control Range Diagnostic Note
Blower Motor Blower motor with fan sub-assembly Min.: 0, Max.: 31 -

OK:

Blower motor with fan sub-assembly operates and blower motor speed level changes.


Result:
Result Proceed to
OK A
NG (Blower motor does not operate) B
NG (Blower motor operates but does not change speed) C



A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

B

2.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN - BODY GROUND)

C

6.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
2.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN - BODY GROUND)
a.

Disconnect the L33 blower motor with fan sub-assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
L33-1 (GND) - Body ground Always Below 1 Ω




OK

3.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN - POWER SOURCE)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN - POWER SOURCE)
a.
U155086E01
0.159,0.078 0.372,0.252 0.214,0.174 10 *a 1.588,0.479 1.908,0.642 0.320,0.163 10 L33 2.447,1.871 2.661,2.034 0.214,0.163 10 +B 2.15,1.593 2.435,1.924 false

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
L33-3 (+B) - Body ground Power switch off 11 to 14 V


Text in Illustration
*a Front view of wire harness connector
(to Blower Motor with Fan Sub-assembly)



OK

4.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN - AIR CONDITIONING AMPLIFIER)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN - AIR CONDITIONING AMPLIFIER)
a.

Disconnect the L17 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
L17-23 (BLW) - L33-2 (SI) Always Below 1 Ω
L17-23 (BLW) - Body ground Always 10 kΩ or higher




OK

5.INSPECT BLOWER MOTOR WITH FAN SUB-ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.INSPECT BLOWER MOTOR WITH FAN SUB-ASSEMBLY
a.

Reconnect the L33 blower motor with fan sub-assembly connector.


b.
U155098E01
0.677,3.001 1.030,3.147 0.353,0.145 10 BLW 0.213,0.182 0.448,0.328 0.236,0.145 10 *a 0.864,2.571 0.864,2.967 false 0.803,1.325 1.124,1.488 0.320,0.163 10 L17

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
L17-23 (BLW) - Body ground Power switch off 4.5 to 5.5 V


Text in Illustration
*a Front view of wire harness connector
(to Air Conditioning Amplifier Assembly)



OK

6.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPLACE BLOWER MOTOR WITH FAN SUB-ASSEMBLY

6.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
a.
U155072E02
2.49,1.094 2.49,1.833 false 0.135,0.063 0.385,0.271 0.25,0.208 10 false *a 2.802,3.854 3.156,4.031 0.354,0.177 10 false GND 2.344,1.844 2.698,2.01 0.354,0.167 10 false BLW 1.677,0.333 2.042,0.615 0.365,0.281 10 false L17

Remove the air conditioning amplifier assembly (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL).


b.

Reconnect the L17 air conditioning amplifier assembly connector.


c.

Turn the power switch on (IG).


d.

Set the blower speed to low.


e.

Measure the waveform between terminal L17-23 (BLW) of the air conditioning amplifier assembly and body ground.

Item Content
Tool setting 1 V/DIV., 500 μs/DIV.
Vehicle condition Power switch on (IG)
Blower set to low

OK:

Waveform is as shown in the illustration.


HINT:

The waveform varies with the blower speed.


Text in Illustration
*a Component with harness connected
(Air Conditioning Amplifier Assembly)



OK

REPLACE BLOWER MOTOR WITH FAN SUB-ASSEMBLY

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY