Home › Vehicle Interior › HEATING / AIR CONDITIONING › SOLAR SENSOR
RM2070E _58 Vehicle Interior _061946 HEATING / AIR CONDITIONING _0301850 SOLAR SENSOR G

HEATING / AIR CONDITIONING  SOLAR SENSOR  INSPECTION  


PROCEDURE

Hide 89120A 1.INSPECT SOLAR SENSOR (AUTOMATIC LIGHT CONTROL SENSOR)

a.
U155019E01
0.123,0.122 0.349,0.338 0.225,0.216 10 *a 0.447,2.796 0.844,2.961 0.397,0.165 10 CLTB 2.461,2.774 2.857,2.939 0.397,0.165 10 CLTE 1.461,2.453 0.714,2.784 false 1.902,2.694 2.423,2.843 false 1.67,0.865 1.990,1.028 0.320,0.163 10 I1

Disconnect the I1 solar sensor (automatic light control sensor) connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
I1-6 (CLTE) - I1-3 (CLTB) Power switch off Below 1 V
I1-6 (CLTE) - I1-3 (CLTB) Power switch on (IG) 11 to 14 V


Text in Illustration
*a Front view of wire harness connector
(to Solar Sensor (Automatic Light Control Sensor))

If the voltage is not as specified, repair or replace the wire harness or connector.


c.
U155026E01
0.057,0.037 0.263,0.204 0.206,0.167 10 *a 0.268,2.431 0.651,2.601 0.383,0.170 10 CLTE 1.49,2.517 0.729,2.517 false 2.826,1.898 3.301,2.096 0.475,0.198 10 NSHA 1.96,1.975 2.783,1.975 false 1.669,0.929 1.989,1.092 0.320,0.163 10 I1

Reconnect the I1 solar sensor (automatic light control sensor) connector.


d.

Turn the power switch on (IG).


e.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
I1-1 (NSHA) - I1-6 (CLTE) Sensor is exposed to electric light 0.8 to 4.3 V
I1-1 (NSHA) - I1-6 (CLTE) Sensor is covered with a cloth Below 0.8 V


Text in Illustration
*a Component with harness connected
(Solar Sensor (Automatic Light Control Sensor))

NOTICE:
·

The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the positive (+) lead to terminal 6 and the negative (-) lead to terminal 1 of the solar sensor.

·

While using the auxiliary battery during inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.



HINT:
·

Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the solar sensor.

·

As the inspection light is moved away from the sensor, the voltage decreases.



If the voltage is not as specified, replace the solar sensor (automatic light control sensor).