HEATING / AIR CONDITIONING  AIR CONDITIONING PRESSURE SENSOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 88719A 1.INSPECT AIR CONDITIONING PRESSURE SENSOR

a.

Check the wire harness.

i.

Disconnect the A31 air conditioning pressure sensor connector.


ii.

Disconnect the L17 air conditioning amplifier assembly connector.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A31-1 (-) - L17-13 (SG-2) Always Below 1 Ω
A31-2 (PR) - L17-9 (PRE) Always Below 1 Ω
A31-3 (+) - L17-10 (S5-3) Always Below 1 Ω
A31-1 (-) - Body ground Always 10 kΩ or higher
A31-2 (PR) - Body ground Always 10 kΩ or higher
A31-3 (+) - Body ground Always 10 kΩ or higher



iv.
U155085E02
1.896,1.563 2.188,1.854 false 0.167,0.083 0.354,0.271 0.188,0.188 10 false *a 1.563,0.438 1.885,0.604 0.323,0.167 10 false A31 2.229,1.823 2.333,1.99 0.104,0.167 10 false +

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A31-3 (+) - Body ground Power switch ON 4.75 to 5.25 V


Text in Illustration
*a Front view of wire harness connector
(to Air Conditioning Pressure Sensor)



b.

Check the air conditioning pressure sensor.

i.

Install a manifold gauge set.


ii.

Connect the air conditioning pressure sensor connector.


iii.

Turn the power switch on (READY).


iv.

A/C switch on.


v.
U155071E02
2.365,1.604 2.094,0.854 false 1.542,1.604 1.813,0.854 false 1.656,0.208 1.99,0.406 0.333,0.198 10 false L17 2.219,1.625 2.552,1.792 0.333,0.167 10 false PRE 0.146,0.094 0.313,0.26 0.167,0.167 10 false *a 1.333,1.625 1.698,1.792 0.365,0.167 10 false SG-2

Measure the voltage according to the value(s) in the table below.

HINT:

Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.


Standard Voltage:
Tester Connection Condition Specified Condition
L17-9 (PRE) - L17-13 (SG-2) Refrigerant pressure:
3.025 MPa (30.8 kgf/cm2, 439 psi) to 0.167 MPa (1.7 kgf/cm2, 24 psi)
0.70 to 4.69 V


Text in Illustration
*a Component with harness connected
(Air Conditioning Amplifier Assembly)