85720E
1.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH
Apply positive (+) auxiliary battery voltage to connector terminal 2 (B).
Do not apply positive (+) auxiliary battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
Connect a ground lead to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).
Check that the motor gear rotates smoothly as follows:
| Measurement Condition | Specified Condition |
|---|---|
1.
Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more. 2.
With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 10 (UP). 3.
Disconnect and reconnect the negative (-) auxiliary battery lead for terminal 10 (UP) within 1 second. |
Motor gear rotates clockwise |
1.
Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect the negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more. 2.
With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 7 (DOWN). 3.
Disconnect and reconnect the negative (-) auxiliary battery lead for terminal 7 (DOWN) within 1 second. |
Motor gear rotates counterclockwise |
| *a | Component without harness connected
(Power Window Regulator Motor Assembly LH) |
| *b | Counterclockwise |
| *c | Clockwise |
If the result is not as specified, replace the power window regulator motor assembly LH.
Reset the power window regulator motor (initialize the pulse sensor) after installing the power window regulator motor and regulator assembly onto the door.
85710F
2.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
Apply positive (+) auxiliary battery voltage to connector terminal 2 (B).
Do not apply positive (+) auxiliary battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
Connect a ground lead to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).
Check that the motor gear rotates smoothly as follows:
| Measurement Condition | Specified Condition |
|---|---|
1.
Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more. 2.
With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 10 (UP). 3.
Disconnect and reconnect the negative (-) auxiliary battery lead for terminal 10 (UP) within 1 second. |
Motor gear rotates counterclockwise |
1.
Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more. 2.
With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 7 (DOWN). 3.
Disconnect and reconnect the negative (-) auxiliary battery lead for terminal 7 (DOWN) within 1 second. |
Motor gear rotates clockwise |
| *a | Component without harness connected
(Power Window Regulator Motor Assembly RH) |
| *b | Clockwise |
| *c | Counterclockwise |
If the result is not as specified, replace the power window regulator motor assembly RH.
Reset the power window regulator motor (initialize the pulse sensor) after installing the power window regulator motor and regulator assembly onto the door.