The combination meter sub-assembly receives information signals from the hazard warning signal switch assembly, and blinks the turn signal lights.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Combination Meter / Data List.
Read the display on the GTS.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Hazard Flasher Switch | Hazard warning signal switch signal/ON or OFF | ON: Hazard warning signal switch on
OFF: Hazard warning signal switch off |
- |
The display is as specified in the normal condition column.
OK
NG
Remove the hazard warning signal switch assembly (See page Vehicle Exterior>LIGHTING (EXT)>HAZARD WARNING SWITCH>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (F) - 5 (E) | Hazard warning switch off | 10 kΩ or higher |
| Hazard warning switch on | Below 1 Ω |
| *a | Component without harness connected
(Hazard Warning Signal Switch Assembly) |
OK
NG
Disconnect the L27 combination meter sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L57-3 (F) - L27-4 (HAZ) | Always | Below 1 Ω |
| L57-5 (E) - Body Ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L57-3 (F) - Body ground | Always | 10 kΩ or higher |
OK
NG