The combination meter sub-assembly receives the turn signal switch information and controls the turn signal lights.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Combination Meter / Data List.
Read the display on the GTS.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Turn Signal Switch (Right) | Turn RH signal switch/OFF or ON | OFF: Turn RH switch off
ON: Turn RH switch on |
- |
| Turn Signal Switch (Left) | Turn LH signal switch/OFF or ON | OFF: Turn LH switch off
ON: Turn LH switch on |
- |
Normal conditions listed above are displayed.
| Result | Proceed to |
|---|---|
| OK | A |
| NG | B |
A
B
Inspect the items that did not change as a result of monitoring the Data List.
Remove the headlight dimmer switch assembly (See page Vehicle Exterior>LIGHTING (EXT)>HEADLIGHT DIMMER SWITCH>REMOVAL).
for Light Control Switch LH Side Type:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 13 (TR) - 12 (EL) | Turn RH switch off | 10 kΩ or higher |
| 15 (TL) - 12 (EL) | Turn LH switch off | 10 kΩ or higher |
| 13 (TR) - 12 (EL) | Turn RH switch on | Below 1 Ω |
| 15 (TL) - 12 (EL) | Turn LH switch on | Below 1 Ω |
Headlight dimmer switch assembly is normal.
| *a | Component without harness connected
(Headlight Dimmer Switch Assembly) |
for Light Control Switch RH Side Type:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 16 (TR) - 19 (EL) | Turn RH switch off | 10 kΩ or higher |
| 18 (TL) - 19 (EL) | Turn LH switch off | 10 kΩ or higher |
| 16 (TR) - 19 (EL) | Turn RH switch on | Below 1 Ω |
| 18 (TL) - 19 (EL) | Turn LH switch on | Below 1 Ω |
Headlight dimmer switch assembly is normal.
| *a | Component without harness connected
(Headlight Dimmer Switch Assembly) |
OK
NG
Disconnect the L27 combination meter sub-assembly connector.
for Light Control Switch LH Side Type:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L27-17 (B) - L47-13 (TR) | Always | Below 1 Ω |
| L27-18 (B) - L47-15 (TL) | Always | Below 1 Ω |
| L47-13 (TR) - Body ground | Always | 10 kΩ or higher |
| L47-15 (TL) - Body ground | Always | 10 kΩ or higher |
| L47-12 (EL) - Body ground | Always | Below 1 Ω |
for Light Control Switch RH Side Type:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L27-17 (B) - L47-16 (TR) | Always | Below 1 Ω |
| L27-18 (B) - L47-18 (TL) | Always | Below 1 Ω |
| L47-16 (TR) - Body ground | Always | 10 kΩ or higher |
| L47-18 (TL) - Body ground | Always | 10 kΩ or higher |
| L47-19 (EL) - Body ground | Always | Below 1 Ω |
OK
NG