Home › Vehicle Exterior › EXTERIOR PANELS / TRIM › ROOF DRIP SIDE FINISH MOULDING
RM2070E _59 Vehicle Exterior _061955 EXTERIOR PANELS / TRIM _0301940 ROOF DRIP SIDE FINISH MOULDING A

EXTERIOR PANELS / TRIM  ROOF DRIP SIDE FINISH MOULDING  INSTALLATION  


PROCEDURE

Hide 75561A 1.INSTALL ROOF DRIP SIDE FINISH MOULDING CLIP (for Standard Roof)

NOTICE:
·

If reusing the clips, do not remove the double-sided tape remaining on the clips and where the clips will be installed on the body.

·

If installing new clips, remove the double-sided tape remaining where the clips will be installed on the body and clean the body with a non-residue solvent.



a.
B229383E02
2.976,0.677 3.148,0.846 0.172,0.169 10 *1 2.55,0.761 2.965,0.761 false 1.429,0.081 1.612,0.346 0.183,0.265 10 *a 2.224,0.944 1.903,0.167 1.903,0.167 1.641,0.167 false

Apply a 2 to 3 mm (0.0787 to 0.118 in.) bead of adhesive (3M DP-105 or equivalent) to new roof drip side finish moulding clips.

Text in Illustration
*1 Adhesive
*a 2 to 3 mm (0.0787 to 0.118 in.) Bead of Adhesive

HINT:

Adhesive strength (tensile strength): 13.7 MPa (140 kgf/cm2, 1987 psi) or more (when the temperature is 23°C (73°F).)



b.

Press and install the 2 roof drip side finish moulding clips.


c.

Install the clips to the positions on the roof panel shown in the illustration. Determine the locations and firmly press and install the 2 roof drip side finish moulding clips after lightly applying adhesive (3M DP-105 or equivalent).

B275162E02
1.458,0.792 1.458,0.198 1.458,0.198 2.458,0.198 false 2.198,0.698 2.198,0.198 false 5.021,0.75 5.021,0.208 5.021,0.208 5.99,0.208 false 5.76,0.708 5.76,0.219 false 2.135,1.427 2.302,1.635 0.167,0.208 10 false A 1.177,2.021 1.344,2.229 0.167,0.208 10 false B 2.104,1.938 2.271,2.146 0.167,0.208 10 false C 5.677,1.396 5.844,1.604 0.167,0.208 10 false D 4.885,1.948 5.052,2.156 0.167,0.208 10 false E 5.865,1.969 6.031,2.177 0.167,0.208 10 false F 1.542,0.313 1.708,0.51 0.167,0.198 10 false a 1.521,1.49 1.688,1.688 0.167,0.198 10 false a 5.646,0.344 5.813,0.542 0.167,0.198 10 false b 5.646,1.51 5.813,1.708 0.167,0.198 10 false b 4.229,1.729 4.5,1.927 0.271,0.198 10 false b-b 0.646,1.729 0.917,1.927 0.271,0.198 10 false a-a 2.479,0.125 2.656,0.292 0.177,0.167 10 false *1 6.01,0.146 6.188,0.313 0.177,0.167 10 false *1

Text in Illustration
*1 Protruding Part - -

Standard Dimension
Installation Area Dimension Measurement
for Front Side A 3.5 mm (0.138 in.)
B 2.5 mm (0.0984 in.)
C 0.8 mm (0.0314 in.)
for Rear Side D 3.5 mm (0.138 in.)
E 0.8 mm (0.0314 in.)
F 3.5 mm (0.138 in.)


d.

Install the roof drip center side finish moulding when 20 minutes or more have elapsed after pressing and installing the 2 roof drip side finish moulding clips.

HINT:
·

Initial hardening time: 20 minutes

·

Complete hardening time: 48 hours




Hide 75556C 2.INSTALL ROOF DRIP CENTER SIDE FINISH MOULDING (for Standard Roof)

a.

Engage the 2 clips and install the roof drip center side finish moulding.


Hide 75561A 3.INSTALL ROOF DRIP SIDE FINISH MOULDING CLIP (for Glass Roof)

NOTICE:
·

If reusing the clips, do not remove the double-sided tape remaining on the clips and where the clips will be installed on the body.

·

If installing new clips, remove the double-sided tape remaining where the clips will be installed on the body and clean the body with a non-residue solvent.



a.
B229383E02
2.976,0.677 3.148,0.846 0.172,0.169 10 *1 2.55,0.761 2.965,0.761 false 1.429,0.081 1.612,0.346 0.183,0.265 10 *a 2.224,0.944 1.903,0.167 1.903,0.167 1.641,0.167 false

Apply a 2 to 3 mm (0.0787 to 0.118 in.) bead of adhesive (3M DP-105 or equivalent) to new roof drip side finish moulding clips.

Text in Illustration
*1 Adhesive
*a 2 to 3 mm (0.0787 to 0.118 in.) Bead of Adhesive

HINT:

Adhesive strength (tensile strength): 13.7 MPa (140 kgf/cm2, 1987 psi) or more (when the temperature is 23°C (73°F).)



b.

Press and install the 2 roof drip side finish moulding clips.


c.

Install the clips to the positions on the roof panel shown in the illustration. Determine the locations and firmly press and install the 2 roof drip side finish moulding clips after lightly applying adhesive (3M DP-105 or equivalent).

B275163E02
2.219,0.719 2.219,0.438 2.219,0.438 2.427,0.438 false 5.01,0.75 5.01,0.469 5.01,0.469 4.802,0.469 false 1.531,0.333 1.698,0.604 0.167,0.271 10 false a 1.542,1.49 1.708,1.76 0.167,0.271 10 false a 2.125,1.406 2.292,1.677 0.167,0.271 10 false A 5.635,0.344 5.802,0.615 0.167,0.271 10 false b 5.615,1.5 5.781,1.771 0.167,0.271 10 false b 5.677,1.396 5.844,1.667 0.167,0.271 10 false D 1.323,1.969 1.49,2.24 0.167,0.271 10 false B 2.146,1.948 2.313,2.219 0.167,0.271 10 false C 4.875,1.948 5.042,2.219 0.167,0.271 10 false E 5.833,1.99 6,2.26 0.167,0.271 10 false F 4.24,1.635 4.49,1.813 0.25,0.177 10 false b-b 0.698,1.635 0.948,1.813 0.25,0.177 10 false a-a 2.458,0.365 2.74,0.604 0.281,0.24 10 false *1 4.656,0.375 4.938,0.615 0.281,0.24 10 false *1

Text in Illustration
*1 Protruding Part - -

Standard Dimension
Installation Area Dimension Measurement
for Front Side A 3.5 mm (0.138 in.)
B 1.7 mm (0.0669 in.)
C 0.9 mm (0.0354 in.)
for Rear Side D 3.5 mm (0.138 in.)
E 0.8 mm (0.0314 in.)
F 3.5 mm (0.138 in.)


d.

Install the roof drip center side finish moulding when 20 minutes or more have elapsed after pressing and installing the 2 roof drip side finish moulding clips.

HINT:
·

Initial hardening time: 20 minutes

·

Complete hardening time: 48 hours




Hide 75556C 4.INSTALL ROOF DRIP CENTER SIDE FINISH MOULDING (for Glass Roof)

a.

Engage the 2 clips and install the roof drip center side finish moulding.