Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HV BATTERY
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301578 HV BATTERY Y

HYBRID / BATTERY CONTROL  HV BATTERY  RECOVERY INSPECTION  


CAUTION / NOTICE / HINT

CAUTION:
·

When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

·

Before returning the HV battery, make sure to perform a pre-return inspection.

·

Accidents such as electric shock may result if the HV battery is discharged improperly and disposed or abandoned.

Therefore, make sure to return the HV battery through an authorized collection agent.

·

To reduce the risk of fire, HV battery must not be stored in an area where they will be exposed to fire or high temperatures.

·

If the temperature of the HV battery is high, leave it to cool down.



HINT:

In order to return the HV battery in a safe manner, it may be necessary to discharge it. The following pre-return inspection procedure can be used to determine whether or not it is necessary to discharge the HV battery the method that may be required.


PROCEDURE

1.INSPECT FOR ELECTROLYTE LEAK
CAUTION:

Wear insulated gloves.


a.
A260371

Position the HV battery as shown in the illustration and leave it for 5 minutes.


b.

Check that no electrolyte is leaking from the HV battery.

OK:

There is no electrolyte leaking from the HV battery.


CAUTION:
·

Perform this procedure in an area where the battery will not be exposed to fire.

·

Do not touch the HV battery, unless absolutely necessary, as electrolyte may be leaking.



NOTICE:

If there is an electrolyte leak, make sure to wear insulated gloves and goggles and clean it using a piece of cloth. Do not leave electrolyte-contaminated cloths unattended. Dispose of them according to law or local regulations.



Result:
Proceed to
OK
NG



OK

2.CHECK FOR DTCS

NG

DISCHARGING (WHEN USING THE SALT WATER SOLUTION)

2.CHECK FOR DTCS
a.

Check the previously recorded DTCs which resulted in replacement of the HV battery.


Result:
Result Proceed to
DTC record not available. A
The HV battery was replaced due to one of the DTCs listed in the following table. B
The HV battery was replaced due to a reason other than the DTCs listed in the following table. C


DTC No. Relevant Diagnosis
P31AA-123 Hybrid Battery Cell High Voltage
P31AB-123 Hybrid Battery Cell Low Voltage
P31AC-123 Hybrid Battery Cell Extreme High Voltage
P31B3-123 Hybrid Battery Voltage High
P0AA6-612 Hybrid Battery Voltage System Isolation Fault


A

3.CHECK HV BATTERY VOLTAGE

B

6.HV BATTERY CONNECTORS VISUAL CHECK

C

5.HV BATTERY VISUAL CHECK
3.CHECK HV BATTERY VOLTAGE
CAUTION:

Wear insulated gloves.


a.
A397871E01
1.854,1.229 2.083,1.417 0.229,0.188 1.635,1.729 1.865,1.917 0.229,0.188 0.51,1.75 0.719,1.958 0.208,0.208 10 false A 0.844,1.031 1.052,1.24 0.208,0.208 10 false B 1.875,1.24 2.073,1.417 0.198,0.177 10 true g4 1.656,1.74 1.854,1.917 0.198,0.177 10 true f4

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
f4-1(+) - Service plug grip connecting terminal A Power switch off Below 114.8 V
g4-1(-) - Service plug grip connecting terminal B Power switch off Below 114.8 V


CAUTION:

Make sure not to cross the electrodes of an electrical tester measurement terminals.



Result:
Proceed to
OK
NG



OK

4.INSULATION INSPECTION OF HV BATTERY

NG

6.HV BATTERY CONNECTORS VISUAL CHECK
4.INSULATION INSPECTION OF HV BATTERY
CAUTION:

Wear insulated gloves.


a.
A260369E01
1.521,1.646 1.813,1.833 0.292,0.188 1.698,1.208 1.99,1.396 0.292,0.188 1.99,0.563 2.958,0.563 true 3.031,0.469 3.281,0.667 0.25,0.198 10 false *a 1.708,1.219 1.979,1.396 0.271,0.177 10 true g4 1.583,1.656 1.802,1.823 0.219,0.167 10 true f4

Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
f4-1(+) - Battery Outer Case Always 1 MΩ or higher
g4-1(-) - Battery Outer Case Always 1 MΩ or higher


Text in Illustration
*a Insulation inspection area of the battery outer case


Result:
Proceed to
OK
NG



OK

5.HV BATTERY VISUAL CHECK

NG

6.HV BATTERY CONNECTORS VISUAL CHECK
5.HV BATTERY VISUAL CHECK
CAUTION:

Wear insulated gloves.


a.

Check that there is no deformation or discoloration of the HV battery.

OK:

There is no deformation or discoloration of the HV battery.



Result:
Proceed to
OK
NG



OK

RETURN HV BATTERY

NG

6.HV BATTERY CONNECTORS VISUAL CHECK
6.HV BATTERY CONNECTORS VISUAL CHECK
CAUTION:

Wear insulated gloves.


a.

Check that there are no deformations or abnormalities in the orange connectors connected to the battery smart unit.

HINT:

If any of the connectors are damaged, a Li-ion battery discharger will not be able to be connected to the HV battery. Soak the HV battery in a saltwater solution to discharge it.


OK:

There are no deformations or abnormalities in the connectors.



Result:
Proceed to
OK
NG



OK

DISCHARGING (WHEN USING THE LI-ION BATTERY DISCHARGER)

NG

DISCHARGING (WHEN USING THE SALT WATER SOLUTION)