When reassembling the combination meter subassembly, eliminate static electricity by touching the vehicle body to prevent components from being damaged.
1.INSTALL METER CIRCUIT PLATE SUB-ASSEMBLY
Push the meter circuit plate sub-assembly in the direction indicated by the arrow to engage the 2 guides.
Install the meter circuit plate sub-assembly with the 2 screws.
2.INSTALL COMBINATION METER WIRE
Connect the connector to install the combination meter wire.
Engage the clamp.
3.INSTALL NO. 2 COMBINATION METER MIRROR
Install the No. 2 combination meter mirror as shown in the illustration.
4.INSTALL NO. 1 COMBINATION METER MIRROR PLATE
Engage the 2 claws to install the No. 1 combination meter mirror plate as shown in the illustration.
5.INSTALL COMBINATION METER MIRROR
Install the combination meter mirror with the 2 screws.
Connect the connector.
6.INSTALL NO. 1 COMBINATION METER MIRROR CASE
Engage the 4 claws.
Install the No. 1 combination meter mirror case with the 2 screws.
7.INSTALL METER CIRCUIT PLATE COVER
Engage the guide and install the meter circuit plate cover as shown in the illustration.
Install the 4 screws.
8.INSTALL COMBINATION METER MIRROR GLASS
Install the combination meter mirror glass with the 4 screws.