Home › Vehicle Interior › SUPPLEMENTAL RESTRAINT SYSTEMS › SPIRAL CABLE › from 2017.12
RM2070E _58 Vehicle Interior _061942 SUPPLEMENTAL RESTRAINT SYSTEMS _0301800 SPIRAL CABLE G

SUPPLEMENTAL RESTRAINT SYSTEMS  SPIRAL CABLE  INSPECTION  


PROCEDURE

Hide 84307 1.INSPECT SPIRAL CABLE WITH SENSOR SUB-ASSEMBLY

a.

Visually check for defects with the spiral cable with sensor sub-assembly removed from the vehicle.

i.

The defects are as follows:

·

Scratches on the spiral cable with sensor sub-assembly

·

Small cracks on the spiral cable with sensor sub-assembly

·

Dents on the spiral cable with sensor sub-assembly

·

Chips on the spiral cable with sensor sub-assembly

·

Cracks or other damage to the connector

OK:

No defects are found.



If any of the defects is found, replace the spiral cable with sensor sub-assembly with a new one.



b.

Check the spiral cable with sensor sub-assembly.

C370355C02
4.354,0.094 4.771,0.344 0.417,0.25 4.229,1.594 4.646,1.844 0.417,0.25 4.927,0.094 5.344,0.344 0.417,0.25 5.323,1.802 5.74,2.031 0.417,0.229 1.083,0.125 1.5,0.375 0.417,0.25 0.24,0.115 0.552,0.313 0.313,0.198 10 false *a 4.49,0.135 4.802,0.333 0.313,0.198 10 false z9 4.313,1.635 4.625,1.833 0.313,0.198 10 false L52 5.031,0.135 5.344,0.333 0.313,0.198 10 false z10 5.406,1.833 5.719,2.031 0.313,0.198 10 false L53 1.219,0.167 1.531,0.365 0.313,0.198 10 false z8
*a Component without harness connected
(Spiral Cable with Sensor Sub-assembly)
- -


NOTICE:

As the spiral cable with sensor sub-assembly may break, do not rotate the spiral cable with sensor sub-assembly more than the specified amount.


i.

Set the spiral cable with sensor sub-assembly to the center position.


ii.

Measure the resistance between each terminal of the spiral cable with sensor sub-assembly according to the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
L52-1 (CCS) - z10-3 Always 3 Ω or less
L52-2 (ECC) - z10-4 Always 3 Ω or less
L52-2 (ECC) - z9-6 Always 3 Ω or less
L52-3 (DISP/+DP) - z9-7 Always 3 Ω or less
L52-4 (EAU) - z9-8 Always 3 Ω or less
L52-5 (AU2) - z9-9 Always 3 Ω or less
L52-6 (AU1) - z9-10 Always 3 Ω or less
L52-8 (HO) - z9-1 Always 3 Ω or less
L52-9 (TRIP) - z9-2 Always 3 Ω or less
L52-10 (AC1/+DP2) - z9-3 Always 3 Ω or less
L52-11 (DIST) - z9-4 Always 3 Ω or less
L52-12 (IL+2) - z9-5 Always 3 Ω or less
L53-1 (D+) - z8-2 Always Below 1 Ω
L53-2 (D-) - z8-1 Always Below 1 Ω



iii.

After setting the spiral cable with sensor sub-assembly to the center position, rotate the spiral cable with sensor sub-assembly 2.5 times clockwise, and measure the resistance as shown in the table below. Then rotate the spiral cable with sensor sub-assembly 5 times counterclockwise, and measure the resistance as shown in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
L52-1 (CCS) - z10-3 Always 3 Ω or less
L52-2 (ECC) - z10-4 Always 3 Ω or less
L52-2 (ECC) - z9-6 Always 3 Ω or less
L52-3 (DISP/+DP) - z9-7 Always 3 Ω or less
L52-4 (EAU) - z9-8 Always 3 Ω or less
L52-5 (AU2) - z9-9 Always 3 Ω or less
L52-6 (AU1) - z9-10 Always 3 Ω or less
L52-8 (HO) - z9-1 Always 3 Ω or less
L52-9 (TRIP) - z9-2 Always 3 Ω or less
L52-10 (AC1/+DP2) - z9-3 Always 3 Ω or less
L52-11 (DIST) - z9-4 Always 3 Ω or less
L52-12 (IL+2) - z9-5 Always 3 Ω or less
L53-1 (D+) - z8-2 Always Below 1 Ω
L53-2 (D-) - z8-1 Always Below 1 Ω



iv.

After setting the spiral cable with sensor sub-assembly to the center position, rotate the spiral cable with sensor sub-assembly 2.5 times clockwise. Then while rotating the spiral cable with sensor sub-assembly 5 times counterclockwise, measure the resistance as shown in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
L52-1 (CCS) - z10-3 Always 3 Ω or less
L52-2 (ECC) - z10-4 Always 3 Ω or less
L52-2 (ECC) - z9-6 Always 3 Ω or less
L52-3 (DISP/+DP) - z9-7 Always 3 Ω or less
L52-4 (EAU) - z9-8 Always 3 Ω or less
L52-5 (AU2) - z9-9 Always 3 Ω or less
L52-6 (AU1) - z9-10 Always 3 Ω or less
L52-8 (HO) - z9-1 Always 3 Ω or less
L52-9 (TRIP) - z9-2 Always 3 Ω or less
L52-10 (AC1/+DP2) - z9-3 Always 3 Ω or less
L52-11 (DIST) - z9-4 Always 3 Ω or less
L52-12 (IL+2) - z9-5 Always 3 Ω or less
L53-1 (D+) - z8-2 Always Below 1 Ω
L53-2 (D-) - z8-1 Always Below 1 Ω


If the result is not as specified, replace the spiral cable with sensor sub-assembly.