88719A
1.INSTALL AIR CONDITIONER PRESSURE SENSOR
Apply a sufficient amount of compressor oil to a new air conditioner pressure sensor.
ND-OIL 11 or equivalent
Keep the O-ring and O-ring fitting surface clean from dirt or any foreign matter.
Do not use any compressor oil other than ND-OIL 11 or equivalent. If any compressor oil other than ND-OIL 11 or equivalent is used, compressor motor insulation performance may decrease, resulting in leakage of electric power.
Using a 27 mm deep socket wrench, install a new air conditioner pressure sensor.
Do not deform the piping.
Make sure to confirm that the piping does not disengage from the plastic clamp.
Connect the connector.
2. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
3.WARM UP COMPRESSOR
4.INSPECT FOR REFRIGERANT LEAK