DTC P321E-318 All HV Gate Blocking Range/Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P321E | 318 | An open or ground short in the HV gate block signal circuit when the gate is operating. When the HV gate block function check is performed (when the ignition switch is turned from on (READY) to off), the inverter voltage (VH) drops and current flows in the inverter. (Both generator (MG1) and motor (MG2) are malfunctioning.) (1 trip detection logic) |
|
| DTC No. | Data List |
| P321E-318 |
|

| 1.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR) |
![]() |
Check the connector connections and contact pressure of the relevant terminals for the power management control ECU connectors (Click here).
|
| ||||
| OK | |
| 2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
![]() |
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU) |
Check that the service plug grip is not installed.
Disconnect connector A47 from the inverter with converter assembly.
Disconnect connector A39 from the power management control ECU.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-31 (HSDN) or A39-31 (HSDN) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A47-31 (HSDN) - A39-31 (HSDN) | Ignition switch off | Below 1 Ω |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Rear view of wire harness connector (to Power Management Control ECU) |
Connect the power management control ECU connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 4.CHECK INVERTER WITH CONVERTER ASSEMBLY |
Check that the service plug grip is not installed.
Disconnect connector A47 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-31 (HSDN) - A47-28 (GND1) | Ignition switch off | 2.65 to 3.55 kΩ |
| *a | Component without harness connected (Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||