Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    U0110-159    Lost Communication with Drive Motor Control Module "A"

DTC    U0110-656    Lost Communication with Drive Motor Control Module "A"

DTC    U0110-657    Lost Communication with Drive Motor Control Module "A"

for Preparation Click here


DESCRIPTION

  1. For a description of the inverter .
    The MG ECU, which is built into in the inverter with converter assembly, controls motor (MG2) based on commands from the power management control ECU. The MG ECU monitors communication data and detects malfunctions.
    The power management control ECU monitors communication data and detects malfunctions. A communication error between the MG ECU and power management control ECU.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
U0110
159
Error in reception from inverter with converter assembly (MG ECU) via serial communication (out of communication standard)
(1 trip detection logic)
  1. Wire harness or connector
  2. Inverter with converter assembly
  3. Motor cable
  4. Hybrid vehicle transaxle assembly
  5. Power management control ECU
  6. PCU fuse
656
Error in reception from inverter with converter assembly (MG ECU) via serial communication (out of communication standard)
(1 trip detection logic)
657
Error in reception from inverter with converter assembly (MG ECU) via serial communication (no reception)
(1 trip detection logic)

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0AA6-526 .

A262682E06


INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (Click here).

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
  1. After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).
  2. If any of the DTCs U0110-159, U0110-656, and U0110-657 was set due to incomplete engagement of the connectors, and if the system returns to normal when the ignition switch is turned to ON (IG) after clearing the DTCs, DTC P324E-788 will be set. Proceed to troubleshooting without considering DTC P324E-788.

HINT:
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
  1. Turn the ignition switch to ON (IG) and wait for 2 minutes or more.

1.CHECK FUSE (PCU)
  1. Remove the PCU fuse from the No. 2 engine room relay block and No. 2 junction block assembly.



    A263604E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    PCU fuse terminals
    Always
    Below 1 Ω

    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
    *2
    PCU Fuse

  1. Install the PCU fuse.



NG
Go to step 18
OK


2.CLEAR DTC
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Read and record the DTCs and freeze frame data.

  1. Clear DTCs and freeze frame data.

  1. Turn the ignition switch off.


NEXT


3.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (IG) and wait for 2 minutes or more.

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    DTC U0110-159, 656 or 657 is output.
    A
    DTC U0110-159, 656 and 657 are not output.
    B

  1. Turn the ignition switch off.



B
CHECK FOR INTERMITTENT PROBLEMS (Click here)
A


4.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE (FOR MG1) CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258644
  1. Remove the inverter terminal cover from the inverter with converter assembly.



    A258645
  1. Remove the inverter cover from the inverter with converter assembly.



    A258647E01
  1. Check that the bolts for the motor cable (for MG1) are tightened to the specified torque, the motor cable (for MG1) is connected securely, and there are no contact problems.

    Specified Condition:
    Bolt A:
    T=8.0 N*m (82 kgf*cm, 71 in.*lbf)
    Bolt B:
    T=9.2 N*m (94 kgf*cm, 81 ft.*lbf)

    NOTICE:
    Make sure that the tightening torque of the bolt B is between 6.4 and 12 N*m (65 and 122 kgf*cm, 57 and 106 in.*lbf).

  1. Disconnect the motor cable (for MG1) from the inverter with converter assembly.

  1. Check for arc marks at the terminals for the motor cable (for MG1).

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the motor cable (for MG1) to the inverter with converter assembly.

  1. Install the inverter cover.

  1. Install the inverter terminal cover.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


5.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE (FOR MG2) CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258644
  1. Remove the inverter terminal cover from the inverter with converter assembly.



    A258646E01
  1. Check that the bolts for the motor cable (for MG2) are tightened to the specified torque, the motor cable (for MG2) is connected securely, and there are no contact problems.

    Specified Condition:
    Bolt A:
    T=8.0 N*m (82 kgf*cm, 71 in.*lbf)
    Bolt B:
    T=9.2 N*m (94 kgf*cm, 81 ft.*lbf)

    NOTICE:
    Make sure that the tightening torque of the bolt B is between 6.4 and 12 N*m (65 and 122 kgf*cm, 57 and 106 in.*lbf).

  1. Disconnect the motor cable (for MG2) from the inverter with converter assembly.

  1. Check for arc marks at the terminals for the motor cable (for MG2).

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the motor cable (for MG2) to the inverter with converter assembly.

  1. Install the inverter terminal cover.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


6.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258644
  1. Remove the inverter terminal cover from the inverter with converter assembly.



    A258645
  1. Remove the inverter cover from the inverter with converter assembly.



    A258648
  1. Disconnect the motor cable from the inverter with converter assembly.



    A268150E04
  1. Check MG1 for an interphase short using a milliohmmeter.

    1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

      HINT:
      If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      a2-1 (W) - a2-2 (U)
      Ignition switch off
      139.1 to 153.7 mΩ
      a2-2 (U) - a2-3 (V)
      Ignition switch off
      139.1 to 153.7 mΩ
      a2-3 (V) - a2-1 (W)
      Ignition switch off
      139.1 to 153.7 mΩ

      Text in Illustration 
      *1
      Shield Ground
      *a
      Motor Cable (for MG1)
      (Inverter with Converter Assembly Side)

      HINT:
      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
      1. R20 = Rt / {1 + 0.00393 X (T - 20)}
      The calculation is based on the following:
      1. R20: Resistance at 20°C (68° F) (mΩ)
      2. Rt: Measured resistance (mΩ)
      3. T: Temperature when the resistance is measured (°C)

  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    a2-1 (W) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a2-2 (U) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a2-3 (V) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher

  1. Connect the motor cable.

  1. Install the inverter cover.

  1. Install the inverter terminal cover.



NG
Go to step 22
OK


7.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258644
  1. Remove the inverter terminal cover from the inverter with converter assembly.



    A258645
  1. Remove the inverter cover from the inverter with converter assembly.



    A258648
  1. Disconnect the motor cable from the inverter with converter assembly.



    A268151E05
  1. Check MG2 for an interphase short using a milliohmmeter.

    1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

      HINT:
      If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      a4-1 (W) - a4-2 (U)
      Ignition switch off
      172.5 to 190.7 mΩ
      a4-2 (U) - a4-3 (V)
      Ignition switch off
      172.5 to 190.7 mΩ
      a4-3 (V) - a4-1 (W)
      Ignition switch off
      172.5 to 190.7 mΩ

      Text in Illustration 
      *1
      Shield Ground
      *a
      Motor Cable (for MG2)
      (Inverter with Converter Assembly Side)

      HINT:
      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
      1. R20 = Rt / {1 + 0.00393 X (T - 20)}
      The calculation is based on the following:
      1. R20: Resistance at 20°C (68° F) (mΩ)
      2. Rt: Measured resistance (mΩ)
      3. T: Temperature when the resistance is measured (°C)

  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    a4-1 (W) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a4-2 (U) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a4-3 (V) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher

  1. Connect the motor cable.

  1. Install the inverter cover.

  1. Install the inverter terminal cover.



NG
Go to step 24
OK


8.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A47 from the inverter with converter assembly.



    A215725E65
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A47-28 (GND1) - Body ground
    Ignition switch off
    Below 1 Ω
    A47-27 (GND2) - Body ground
    Ignition switch off
    Below 1 Ω

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the ignition switch to ON (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A47-10 (+B) - Body ground
    Ignition switch ON (IG)
    11 to 14 V
    A47-9 (+B2) - Body ground
    Ignition switch ON (IG)
    11 to 14 V

    NOTICE:
    Turning the ignition switch to ON (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the ignition switch off.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9.CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM)
  1. Connect an oscilloscope between the power management control ECU terminals specified in the following table.

  1. Turn the ignition switch to ON (IG).



    A204496E12
  1. Measure the waveform.
    Item
    Contents
    Tester Connection
    CH1: A39-21 (CLK+) - G57-6 (E1)
    CH2: A39-20 (CLK-) - G57-6 (E1)
    Equipment Setting
    1V/DIV., 1μs/DIV.
    Condition
    Ignition switch ON (IG)

    Result:
    Result
    Proceed to
    The waveform appears as shown in the illustration.
    A
    The waveform differs from the one shown in the illustration.
    B

    Text in Illustration 
    *a
    Component with harness connected
    (Power Management Control ECU)

    HINT:
    1. Inspect with the connector connected.
    2. If pulses are generated, the shape of the waveform can be assumed to be normal.
    3. The shape of the waveform may vary according to communication conditions.

  1. Turn the ignition switch off.



B
Go to step 12
A


10.CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM)
  1. Connect an oscilloscope between the power management control ECU terminals specified in the following table.

  1. Turn the ignition switch to ON (IG).



    A204500E13
  1. Measure the waveform.
    Item
    Contents
    Tester Connection
    CH1: A39-33 (REQ+) - G57-6 (E1)
    CH2: A39-32 (REQ-) - G57-6 (E1)
    Equipment Setting
    1V/DIV., 1ms/DIV.
    Condition
    Ignition switch ON (IG)

    Result:
    Result
    Proceed to
    The waveform appears as shown in the illustration.
    A
    The waveform differs from the one shown in the illustration.
    B

    Text in Illustration 
    *a
    Component with harness connected
    (Power Management Control ECU)

    HINT:
    1. Inspect with the connector connected.
    2. If pulses are generated, the shape of the waveform can be assumed to be normal.
    3. The shape of the waveform may vary according to communication conditions.

  1. Turn the ignition switch off.



B
Go to step 14
A


11.CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM)
  1. Connect an oscilloscope between the power management control ECU terminals specified in the following table.

  1. Turn the ignition switch to ON (IG).



    A204498E21
  1. Measure the waveform.
    Item
    Contents
    Tester Connection
    CH1: A39-30 (MTH+) - G57-6 (E1)
    CH2: A39-29 (MTH-) - G57-6 (E1)
    Equipment Setting
    1V/DIV., 200μs/DIV.
    Condition
    Ignition switch ON (IG)

    Result:
    Result
    Proceed to
    The waveform appears as shown in the illustration.
    A
    The waveform differs from the one shown in the illustration.
    B

    Text in Illustration 
    *a
    Component with harness connected
    (Power Management Control ECU)

    HINT:
    1. Inspect with the connector connected.
    2. If pulses are generated, the shape of the waveform can be assumed to be normal.
    3. The shape of the waveform may vary according to communication conditions.

  1. Turn the ignition switch off.



B
Go to step 16
A

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

12.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A39 from the power management control ECU.

  1. Disconnect connector A47 from the inverter with converter assembly.

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the ignition switch to ON (IG).



    A216634E31
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-21 (CLK+) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    A39-20 (CLK-) - Body ground
    Ignition switch ON (IG)
    Below 1 V

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)
    *b
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the ignition switch to ON (IG) with the power management control ECU connector and the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the ignition switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    A39-21 (CLK+) - A47-5 (CLK+)
    Ignition switch off
    Below 1 Ω
    A39-20 (CLK-) - A47-15 (CLK-)
    Ignition switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    A39-21 (CLK+) or A47-5 (CLK+) - Body ground and other terminals
    Ignition switch off
    10 kΩ or higher
    A39-20 (CLK-) or A47-15 (CLK-) - Body ground and other terminals
    Ignition switch off
    10 kΩ or higher

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the inverter with converter assembly connector.

  1. Connect the power management control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


13.CHECK INVERTER WITH CONVERTER ASSEMBLY
  1. Disconnect connector A39 from the power management control ECU.



    A204444E33
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-21 (CLK+) - A39-20 (CLK-)
    Ignition switch off
    80 to 170 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)

  1. Connect the power management control ECU connector.



NG
REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

14.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A39 from the power management control ECU.

  1. Disconnect connector A47 from the inverter with converter assembly.

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the ignition switch to ON (IG).



    A216634E32
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-33 (REQ+) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    A39-32 (REQ-) - Body ground
    Ignition switch ON (IG)
    Below 1 V

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)
    *b
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the ignition switch to ON (IG) with the power management control ECU connector and the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the ignition switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    A39-33 (REQ+) - A47-6 (REQ+)
    Ignition switch off
    Below 1 Ω
    A39-32 (REQ-) - A47-16 (REQ-)
    Ignition switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    A39-33 (REQ+) or A47-6 (REQ+) - Body ground and other terminals
    Ignition switch off
    10 kΩ or higher
    A39-32 (REQ-) or A47-16 (REQ-) - Body ground and other terminals
    Ignition switch off
    10 kΩ or higher

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the inverter with converter assembly connector.

  1. Connect the power management control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


15.CHECK INVERTER WITH CONVERTER ASSEMBLY
  1. Disconnect connector A39 from the power management control ECU.



    A204444E34
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-33 (REQ+) - A39-32 (REQ-)
    Ignition switch off
    80 to 170 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)

  1. Connect the power management control ECU connector.



NG
REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

16.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A39 from the power management control ECU.

  1. Disconnect connector A47 from the inverter with converter assembly.

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the ignition switch to ON (IG).



    A216634E33
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-30 (MTH+) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    A39-29 (MTH-) - Body ground
    Ignition switch ON (IG)
    Below 1 V

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)
    *b
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the ignition switch to ON (IG) with the power management control ECU connector and the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the ignition switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    A39-30 (MTH+) - A47-7 (MTH+)
    Ignition switch off
    Below 1 Ω
    A39-29 (MTH-) - A47-17 (MTH-)
    Ignition switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    A39-30 (MTH+) or A47-7 (MTH+) - Body ground and other terminals
    Ignition switch off
    10 kΩ or higher
    A39-29 (MTH-) or A47-17 (MTH-) - Body ground and other terminals
    Ignition switch off
    10 kΩ or higher

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the inverter with converter assembly connector.

  1. Connect the power management control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


17.CHECK POWER MANAGEMENT CONTROL ECU

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A47 from the inverter with converter assembly.



    A249168E14
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-30 (MTH+) - A39-29 (MTH-)
    Ignition switch off
    80 to 170 Ω

    Text in Illustration 
    *a
    Component with harness connected
    (Power Management Control ECU)

  1. Connect the inverter with converter assembly connector.



NG
REPLACE POWER MANAGEMENT CONTROL ECU (Click here)
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

18.REPLACE FUSE (PCU)


    A263604E02
  1. Replace the PCU fuse.
    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
    *2
    PCU Fuse

  1. Turn the ignition switch to ON (READY).

  1. Check if there is an open circuit in the PCU fuse in the No. 2 engine room relay block and No. 2 junction block assembly.

    OK:
    There is no open circuit in the PCU fuse.

    HINT:
    If the fuse does not become open again after turning the ignition switch to ON (READY), it can be assumed that the previous fuse failed due to age.

  1. Turn the ignition switch off.



NG
Go to step 19
OK

COMPLETED 

19.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - PCU FUSE)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



    A263604E02
  1. Remove the PCU fuse from the No. 2 engine room relay block and No. 2 junction block assembly.
    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
    *2
    PCU Fuse

  1. Disconnect connector A47 from the inverter with converter assembly.



  1. Measure the resistance according to the value(s) in the table below.


    A264719E01


    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
    *2
    PCU Fuse
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)
    -
    -

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    A47-10 (+B), A47-9 (+B2) or 2 (PCU fuse terminal) - Body ground and other terminals
    Ignition switch off
    10 kΩ or higher

  1. Connect the inverter with converter assembly connector.

  1. Install the PCU fuse.



NG
Go to step 21
OK


20.REPLACE INVERTER WITH CONVERTER ASSEMBLY
(Click here)

NEXT

REPLACE FUSE (PCU) 

21.REPAIR OR REPLACE HARNESS OR CONNECTOR

NEXT

REPLACE FUSE (PCU) 

22.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE (FOR MG1) CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the inverter with converter assembly (Click here).



    A258652E01
  1. Check that the bolts for the motor cable (for MG1) are tightened to the specified torque, the motor cable (for MG1) is connected securely, and there are no contact problems.

    Specified Condition:
    Bolt A:
    T=19.5 N*m (199 kgf*cm, 14 ft.*lbf)
    Bolt B:
    T=10 N*m (102 kgf*cm, 7 ft.*lbf)

    NOTICE:
    1. Make sure that the tightening torque of the bolt A is between 13.5 and 25 N*m (138 and 255 kgf*cm, 10 and 18 ft.*lbf).
    2. Make sure that the tightening torque of the bolt B is between 8 and 12 N*m (82 and 122 kgf*cm, 71 and 106 in.*lbf).

  1. Disconnect the motor cable (for MG1) from the hybrid vehicle transaxle assembly.

  1. Check for arc marks at the terminals for the motor cable (for MG1).

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the motor cable (for MG1) to the hybrid vehicle transaxle assembly.

  1. Install the inverter with converter assembly.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


23.CHECK MOTOR CABLE (FOR MG1)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the motor cable (Click here).



    A258650E02
  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    a2-1 (W) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a2-2 (U) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a2-3 (V) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher

    Text in Illustration 
    *1
    Shield ground
    *a
    Motor Cable (for MG1)
    (Inverter with Converter Assembly Side)
    *b
    Motor Cable (for MG1)
    (Hybrid Vehicle Transaxle Assembly Side)

    NOTICE:
    Wrap the terminal of the motor cable (for MG1) with insulating tape to prevent them from coming into contact with body ground

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    a2-1 (W) - a1-1 (W)
    Ignition switch off
    Below 1 Ω
    a2-2 (U) - a1-2 (U)
    Ignition switch off
    Below 1 Ω
    a2-3 (V) - a1-3 (V)
    Ignition switch off
    Below 1 Ω
    a2-1 (W) - a1-2 (U)
    Ignition switch off
    100 MΩ or higher
    a2-2 (U) - a1-3 (V)
    Ignition switch off
    100 MΩ or higher
    a2-3 (V) - a1-1 (W)
    Ignition switch off
    100 MΩ or higher

  1. Install the motor cable.



NG
REPLACE MOTOR CABLE (Click here)
OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)  

24.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE (FOR MG2) CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258653E01
  1. Check that the bolts for the motor cable (for MG2) are tightened to the specified torque, the motor cable (for MG2) is connected securely, and there are no contact problems.

    Specified Condition:
    Bolt A:
    T=19.5 N*m (199 kgf*cm, 14 ft.*lbf)
    Bolt B:
    T=10 N*m (102 kgf*cm, 7 ft.*lbf)

    NOTICE:
    1. Make sure that the tightening torque of the bolt A is between 13.5 and 25 N*m (138 and 255 kgf*cm, 10 and 18 ft.*lbf).
    2. Make sure that the tightening torque of the bolt B is between 8 and 12 N*m (82 and 122 kgf*cm, 71 and 106 in.*lbf).

  1. Disconnect the motor cable (for MG2) from the hybrid vehicle transaxle assembly.

  1. Check for arc marks at the terminals for the motor cable (for MG2).

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the motor cable (for MG2) to the hybrid vehicle transaxle assembly.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


25.CHECK MOTOR CABLE (FOR MG2)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the motor cable (Click here).



    A258651E01
  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    a4-1 (W) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a4-2 (U) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a4-3 (V) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher

    Text in Illustration 
    *1
    Shield ground
    *a
    Motor Cable (for MG2)
    (Inverter with Converter Assembly Side)
    *b
    Motor Cable (for MG2)
    (Hybrid Vehicle Transaxle Assembly Side)

    NOTICE:
    Wrap the terminal of the motor cable (for MG2) with insulating tape to prevent them from coming into contact with body ground

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    a4-1 (W) - a3-1 (W)
    Ignition switch off
    Below 1 Ω
    a4-2 (U) - a3-3 (U)
    Ignition switch off
    Below 1 Ω
    a4-3 (V) - a3-2 (V)
    Ignition switch off
    Below 1 Ω
    a4-1 (W) - a3-3 (U)
    Ignition switch off
    100 MΩ or higher
    a4-2 (U) - a3-2 (V)
    Ignition switch off
    100 MΩ or higher
    a4-3 (V) - a3-1 (W)
    Ignition switch off
    100 MΩ or higher

  1. Install the motor cable.



NG
REPLACE MOTOR CABLE (Click here)
OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)