DTC P0A0D-350 High Voltage System Inter-Lock Circuit High |
DTC P0A0D-351 High Voltage System Inter-Lock Circuit High |
| DTC No. | INF Code | DTC Detection Condition | Trouble Are |
| P0A0D | 350 | Either of the following conditions is met:
|
|
| P0A0D | 351 | Interlock signal line opens while the vehicle is being driven (at 5 km/h or more) (1 trip detection logic) |

| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P0A0D only is output. | A |
| P0A1D is also output | B |
Turn the ignition switch off.
|
| ||||
| A | |
| 2.CLEAR DTC |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read and record the DTCs and freeze frame data.
Clear DTCs and freeze frame data.
Turn the ignition switch off.
| NEXT | |
| 3.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P0A0D-350 or P0A0D-351 is output again. | A |
| Neither P0A0D-350 or P0A0D-351 is output again. | B |
Turn the ignition switch off.
|
| ||||
| A | |
| 4.CHECK SERVICE PLUG GRIP |
![]() |
Check if the service plug grip is installed correctly.
| *1 | Service Plug Grip |
|
| ||||
| OK | |
| 5.CHECK INVERTER TERMINAL COVER |
Check that the service plug grip is not installed.
![]() |
Check if the inverter terminal cover of the inverter with converter assembly is installed correctly.
|
| ||||
| OK | |
| 6.CHECK FRAME WIRE |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Remove the inverter cover from the inverter with converter assembly.
![]() |
Check if the frame wire P1 is connected correctly.
Install the inverter cover.
Install the inverter terminal cover.
|
| ||||
| OK | |
| 7.CHECK POWER MANAGEMENT CONTROL ECU |
Check that the service plug grip is not installed.
Disconnect connector A47 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-35 (ILKI) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 8.CHECK INVERTER WITH CONVERTER ASSEMBLY (INTERLOCK) |
Check that the service plug grip is not installed.
Disconnect connector A47 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-35 (ILKI) - A47-36 (ILKO) | Ignition switch off | 10 Ω or less |
| *a | Component without harness connected (Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 9.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - BODY GROUND) |
Check that the service plug grip is not installed.
Disconnect connector A47 from the inverter with converter assembly.
Install the service plug grip.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-36 (ILKO) - Body ground | Ignition switch off | Less than 1 Ω |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Remove the service plug grip.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 10.CHECK CONNECTOR CONNECTION CONDITION (INTERLOCK CIRCUIT) |
Check the connections of each connector.
|
| ||||
| OK | ||
| ||
| 11.CHECK SERVICE PLUG GRIP |
Remove the service plug grip.
![]() |
Check the condition of the service plug grip interlock.
| *1 | Service Plug Grip |
![]() |
Install the service plug grip.
| *1 | Service Plug Grip |
|
| ||||
| OK | |
| 12.CHECK CONNECTOR CONNECTION CONDITION (INTERLOCK CONNECTOR) |
Check that the service plug grip is not installed.
![]() |
Check that the interlock connector at the service plug grip installation socket is connected correctly.
| *1 | Interlock Connector |
|
| ||||
| OK | |
| 13.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - SERVICE PLUG GRIP) |
Check that the service plug grip is not installed.
Disconnect connector A47 from the inverter with converter assembly.
Disconnect connector M42 from the service plug.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-36 (ILKO) - M42-1 (ILK) | Ignition switch off | Below 1 Ω |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Service Plug Grip) |
Connect the service plug grip connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||
| 14.CHECK INVERTER TERMINAL COVER |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Check the condition of the inverter terminal cover interlock.
Install the inverter terminal cover.
|
| ||||
| OK | |
| 15.CHECK FRAME WIRE (FRAME WIRE CONNECTOR) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Remove the inverter cover from the inverter with converter assembly.
![]() |
Disconnect the frame wire P1 from the inverter with converter assembly.
![]() |
Check the frame wire interlock.
Connect the frame wire to the inverter with converter assembly.
Install the inverter cover.
Install the inverter terminal cover.
|
| ||||
| OK | ||
| ||
| 16.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER) |
Check that the service plug grip is not installed.
Disconnect connector A47 from the inverter with converter assembly.
![]() |
Disconnect connector A38 from the power management control ECU.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A38-32 (ILK) - A47-35 (ILKI) | Ignition switch off | Below 1 Ω |
| *a | Rear view of wire harness connector (to Power Management Control ECU) |
| *b | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the power management control ECU connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||