SHIFT LEVER POSITION SENSOR > INSPECTION |
| 1. INSPECT SHIFT LEVER POSITION SENSOR |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Shift Lever Position | Specified Condition |
| 8 (+B) - 1 (D) | D | Below 1 Ω |
| Except D | 10 kΩ or higher | |
| 8 (+B) - 2 (N) | N | Below 1 Ω |
| Except N | 4.2 to 5.2 kΩ | |
| 8 (+B) - 3 (P) | P | Below 1 Ω |
| Except P | 10 kΩ or higher | |
| 8 (+B) - 4 (R) | R | Below 1 Ω |
| Except R | 10 kΩ or higher | |
| 8 (+B) - 5 (MJ) | ALL | Below 1 Ω |
| 8 (+B) - 6 (FD) | D or B | Below 1 Ω |
| Except D and B | 10 kΩ or higher | |
| 8 (+B) - 7 (B) | B | Below 1 Ω |
| Except B | 10 kΩ or higher | |
| 8 (+B) - 9 (RV) | R | Below 1 Ω |
| Except R | 10 kΩ or higher |
| *a | Component without harness connected (Shift Lever Position Sensor) |