Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM

DTC    B1412/12    Ambient Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The ambient temperature sensor (thermistor assembly) is installed in front of the condenser to detect the ambient temperature. Its signal is used for air conditioning control in AUTO mode. This sensor is connected to the air conditioning amplifier assembly and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the ambient temperature sensor (thermistor assembly) changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies a voltage (5 V) to the ambient temperature sensor (thermistor assembly) and reads voltage changes due to changes in the resistance of the ambient temperature sensor (thermistor assembly).

DTC No.
DTC Detection Condition
Trouble Area
B1412/12
Open or short in ambient temperature sensor (thermistor assembly) circuit
  1. Ambient temperature sensor (thermistor assembly)
  2. Harness or connector between ambient temperature sensor (thermistor assembly) and air conditioning amplifier assembly
  3. Air conditioning amplifier assembly

WIRING DIAGRAM


E236722E11


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (IG).

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Air Conditioner / Data List.

  1. Check the value(s) by referring to the table below.


Air Conditioner 
Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Ambient Temp Sensor
Ambient temperature sensor (thermistor assembly) /
Min: -23.30°C (-9.94°F)
Max: 65.95°C (150.71°F)
Actual ambient temperature displayed
-

OK:
The display is as specified in the normal condition column.


Result:

Result
Proceed to
NG
A
OK (When troubleshooting according to Problem Symptoms Table)
B
OK (When troubleshooting according to the DTC)
C



B
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
A


2.INSPECT AMBIENT TEMPERATURE SENSOR (THERMISTOR ASSEMBLY)
  1. Remove the ambient temperature sensor (thermistor assembly) (Click here).



    E214922E29
  1. Disconnect the A26 ambient temperature sensor (thermistor assembly) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A26-1 (+) - A26-2 (-)
    10°C (50°F)
    3.00 to 3.73 kΩ
    A26-1 (+) - A26-2 (-)
    15°C (59°F)
    2.45 to 2.88 kΩ
    A26-1 (+) - A26-2 (-)
    20°C (68°F)
    1.95 to 2.30 kΩ
    A26-1 (+) - A26-2 (-)
    25°C (77°F)
    1.60 to 1.80 kΩ
    A26-1 (+) - A26-2 (-)
    30°C (86°F)
    1.28 to 1.47 kΩ
    A26-1 (+) - A26-2 (-)
    35°C (95°F)
    1.00 to 1.22 kΩ
    A26-1 (+) - A26-2 (-)
    40°C (104°F)
    0.80 to 1.00 kΩ
    A26-1 (+) - A26-2 (-)
    45°C (113°F)
    0.65 to 0.85 kΩ
    A26-1 (+) - A26-2 (-)
    50°C (122°F)
    0.50 to 0.70 kΩ
    A26-1 (+) - A26-2 (-)
    55°C (131°F)
    0.44 to 0.60 kΩ
    A26-1 (+) - A26-2 (-)
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Hold the sensor only by its connector. Touching the sensor may change the resistance value.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).

    Text in Illustration 
    *a
    Component without harness connected
    (Ambient Temperature Sensor (Thermistor Assembly))
    *b
    Sensing Portion
    *c
    Resistance (kΩ)
    *d
    Allowable Range
    *e
    Temperature (°C (°F))



NG
REPLACE AMBIENT TEMPERATURE SENSOR (THERMISTOR ASSEMBLY) (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR (THERMISTOR ASSEMBLY) - AIR CONDITIONING AMPLIFIER ASSEMBLY)
  1. Disconnect the G34 air conditioning amplifier assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    G34-5 (TAM) - A26-1 (+)
    Always
    Below 1 Ω
    G34-13 (SG-2) - A26-2 (-)
    Always
    Below 1 Ω
    G34-5 (TAM) - Body ground
    Always
    10 kΩ or higher
    G34-13 (SG-2) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)