AIR CONDITIONING SYSTEM > Back-up Power Source Circuit |

| 1.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AUXILIARY BATTERY) |
Disconnect the G34 air conditioning amplifier assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| G34-21 (B) - Body ground | Ignition switch off | 11 to 14 V |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BODY GROUND) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| G34-14 (GND) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||