Home › Vehicle Interior › SUPPLEMENTAL RESTRAINT SYSTEMS › SPIRAL CABLE

SPIRAL CABLE > INSPECTION

for Preparation Click here



1. INSPECT SPIRAL CABLE WITH SENSOR SUB-ASSEMBLY
  1. Visually check for defects with the spiral cable with sensor sub-assembly removed from the vehicle.

    1. The defects are as follows:

      1. Scratches
      2. Small cracks
      3. Dents
      4. Chips
      5. Cracks or other damage to the connector

        OK:
        No defects are found.

      If any of the defects is found, replace the spiral cable with sensor sub-assembly with a new one.



    C180136E17
  1. Check the spiral cable with sensor sub-assembly.
    Text in Illustration 
    *1
    Color: Orange
    *2
    Color: Black
    *a
    Component without harness connected
    (Spiral Cable with Sensor Sub-assembly)

    NOTICE:
    As the spiral cable with sensor sub-assembly may break, do not rotate the spiral cable with sensor sub-assembly more than the specified amount.


    1. Set the spiral cable with sensor sub-assembly to the center position .

    2. Measure the resistance between each terminal of the spiral cable with sensor sub-assembly according to the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      G5-1 (CCS) - z6-3
      Always
      3 Ω or less
      G5-2 (ECC) - z6-4
      Always
      3 Ω or less
      G5-3 (DISP/TX1) - z2-7
      Always
      3 Ω or less
      G5-4 (EAU) - z2-8
      Always
      3 Ω or less
      G5-5 (AU2) - z2-9
      Always
      3 Ω or less
      G5-6 (AU1) - z2-10
      Always
      3 Ω or less
      G5-8 (HO) - z2-1
      Always
      3 Ω or less
      G5-9 (TRIP/IG) - z2-2
      Always
      3 Ω or less
      G5-10 (AC1) - z2-3
      Always
      3 Ω or less
      G5-12 (IL+2) - z2-5
      Always
      3 Ω or less
      G19-1 (D+) - z3-2
      Always
      Below 1 Ω
      G19-2 (D-) - z3-1
      Always
      Below 1 Ω
      G19-3 (D2-) - z5-1
      Always
      Below 1 Ω
      G19-4 (D2+) - z5-2
      Always
      Below 1 Ω

    3. After setting the spiral cable with sensor sub-assembly to the center position, rotate the spiral cable with sensor sub-assembly 2.5 times clockwise, and measure the resistance as shown in the table below. Then rotate the spiral cable with sensor sub-assembly 5 times counterclockwise, and measure the resistance as shown in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      G5-1 (CCS) - z6-3
      Always
      3 Ω or less
      G5-2 (ECC) - z6-4
      Always
      3 Ω or less
      G5-3 (DISP/TX1) - z2-7
      Always
      3 Ω or less
      G5-4 (EAU) - z2-8
      Always
      3 Ω or less
      G5-5 (AU2) - z2-9
      Always
      3 Ω or less
      G5-6 (AU1) - z2-10
      Always
      3 Ω or less
      G5-8 (HO) - z2-1
      Always
      3 Ω or less
      G5-9 (TRIP/IG) - z2-2
      Always
      3 Ω or less
      G5-10 (AC1) - z2-3
      Always
      3 Ω or less
      G5-12 (IL+2) - z2-5
      Always
      3 Ω or less
      G19-1 (D+) - z3-2
      Always
      Below 1 Ω
      G19-2 (D-) - z3-1
      Always
      Below 1 Ω
      G19-3 (D2-) - z5-1
      Always
      Below 1 Ω
      G19-4 (D2+) - z5-2
      Always
      Below 1 Ω

    4. After setting the spiral cable with sensor sub-assembly to the center position, rotate the spiral cable with sensor sub-assembly 2.5 times clockwise. Then while rotating the spiral cable with sensor sub-assembly 5 times counterclockwise, measure the resistance as shown in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      G5-1 (CCS) - z6-3
      Always
      3 Ω or less
      G5-2 (ECC) - z6-4
      Always
      3 Ω or less
      G5-3 (DISP/TX1) - z2-7
      Always
      3 Ω or less
      G5-4 (EAU) - z2-8
      Always
      3 Ω or less
      G5-5 (AU2) - z2-9
      Always
      3 Ω or less
      G5-6 (AU1) - z2-10
      Always
      3 Ω or less
      G5-8 (HO) - z2-1
      Always
      3 Ω or less
      G5-9 (TRIP/IG) - z2-2
      Always
      3 Ω or less
      G5-10 (AC1) - z2-3
      Always
      3 Ω or less
      G5-12 (IL+2) - z2-5
      Always
      3 Ω or less
      G19-1 (D+) - z3-2
      Always
      Below 1 Ω
      G19-2 (D-) - z3-1
      Always
      Below 1 Ω
      G19-3 (D2-) - z5-1
      Always
      Below 1 Ω
      G19-4 (D2+) - z5-2
      Always
      Below 1 Ω

      If the result is not as specified, replace the spiral cable with sensor sub-assembly.