Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING PRESSURE SENSOR

AIR CONDITIONING PRESSURE SENSOR > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT AIR CONDITIONING PRESSURE SENSOR
  1. Check the wire harness.

    1. Disconnect the A25 air conditioning pressure sensor connector.

    2. Disconnect the G34 air conditioning amplifier assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      A25-1 (-) - G34-13 (SG-2)
      Always
      Below 1 Ω
      A25-2 (PR) - G34-9 (PRE)
      Always
      Below 1 Ω
      A25-3 (+) - G34-10 (S5-3)
      Always
      Below 1 Ω
      A25-1 (-) - Body ground
      Always
      10 kΩ or higher
      A25-2 (PR) - Body ground
      Always
      10 kΩ or higher
      A25-3 (+) - Body ground
      Always
      10 kΩ or higher

      1. If the resistance is not as specified, repair the wire harness.

    4. Reconnect the G34 air conditioning amplifier assembly connector.

    5. Turn the ignition switch to ON (IG).

    6. Measure the voltage according to the value(s) in the table below.

      Standard Voltage:
      Tester Connection
      Switch condition
      Specified Condition
      A25-3 (+) - Body ground
      Ignition switch ON (IG)
      4.75 to 5.25 V
      A25-3 (+) - Body ground
      Ignition switch off
      Below 1 V

      1. If the voltage is not as specified, repair the wire harness or replace air conditioning amplifier assembly.



  1. Check the air conditioning pressure sensor.

    1. Install a manifold gauge set.

    2. Connect the connector to the air conditioning pressure sensor.

    3. Turn the ignition switch to ON (READY).

    4. Turn the A/C switch on.



    5. E227427E37
    6. Measure the voltage according to the value(s) in the table below.

      HINT:
      Check from the rear of the connector while it is connected to the air conditioning amplifier.

      Standard Voltage:
      Tester Connection
      Condition
      Specified Condition
      G34-9 (PRE) - G34-13 (SG-2)
      Refrigerant pressure:
      (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 25 psi))
      0.74 to 4.62 V

      Text in Illustration 
      *a
      Component with harness connected
      (Air Conditioning Amplifier)
      1. If the voltage is not as specified, replace the air conditioning pressure sensor.