POWER WINDOW MASTER SWITCH > INSPECTION |
| 1. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (w/ Rear Power Window) |
![]() |
Check the switch function.
Turn the window lock switch off and operate the switches on the power window regulator master switch assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 4 (AUTO) - 1 (E) | AUTO UP | Below 1 Ω |
| 8 (U) - 1 (E) | AUTO UP | Below 1 Ω |
| 5 (D) - 6 (B) | AUTO UP | Below 1 Ω |
| 8 (U) - 1 (E) | MANUAL UP | Below 1 Ω |
| 5 (D) - 6 (B) | MANUAL UP | Below 1 Ω |
| 8 (U) - 5 (D) | OFF | Below 1 Ω |
| 8 (U) - 6 (B) | OFF | Below 1 Ω |
| 5 (D) - 1 (E) | MANUAL DOWN | Below 1 Ω |
| 8 (U) - 6 (B) | MANUAL DOWN | Below 1 Ω |
| 4 (AUTO) - 1 (E) | AUTO DOWN | Below 1 Ω |
| 5 (D) - 1 (E) | AUTO DOWN | Below 1 Ω |
| 8 (U) - 6 (B) | AUTO DOWN | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| 6 (B) - 16 (U) | UP | Below 1 Ω |
| 1 (E) - 15 (D) | UP | Below 1 Ω |
| 1 (E) - 16 (U) | OFF | Below 1 Ω |
| 1 (E) - 15 (D) | OFF | Below 1 Ω |
| 1 (E) - 16 (U) | DOWN | Below 1 Ω |
| 6 (B) - 15 (D) | DOWN | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| 6 (B) - 10 (U) | UP | Below 1 Ω |
| 1 (E) - 18 (D) | UP | Below 1 Ω |
| 1 (E) - 18 (D) | OFF | Below 1 Ω |
| 1 (E) - 10 (U) | OFF | Below 1 Ω |
| 6 (B) - 18 (D) | DOWN | Below 1 Ω |
| 1 (E) - 10 (U) | DOWN | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| 6 (B) - 12 (U) | UP | Below 1 Ω |
| 1 (E) - 13 (D) | UP | Below 1 Ω |
| 1 (E) - 13 (D) | OFF | Below 1 Ω |
| 1 (E) - 12 (U) | OFF | Below 1 Ω |
| 6 (B) - 13 (D) | DOWN | Below 1 Ω |
| 1 (E) - 12 (U) | DOWN | Below 1 Ω |
| *a | Component without harness connected (Power Window Regulator Master Switch Assembly) |
![]() |
Check that the LED illuminates.
Apply auxiliary battery voltage to the power window regulator master switch assembly and check that the LED illuminates.
| Measurement Condition | Specified Condition |
| Auxiliary battery positive (+) → Terminal 3 (LED) Auxiliary battery negative (-) → Terminal 1 (E) | LED illuminates |
| *a | Component without harness connected (Power Window Regulator Master Switch Assembly) |
| 2. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (w/o Rear Power Window) |
![]() |
Check the switch function.
Turn the window lock switch off and operate the switches on the power window regulator master switch assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (AUTO) - 7 (E) | AUTO UP | Below 1 Ω |
| 18 (U) - 7 (E) | AUTO UP | Below 1 Ω |
| 10 (D) - 15 (B) | AUTO UP | Below 1 Ω |
| 18 (U) - 7 (E) | MANUAL UP | Below 1 Ω |
| 10 (D) - 15 (B) | MANUAL UP | Below 1 Ω |
| 18 (U) - 10 (D) | OFF | Below 1 Ω |
| 18 (U) - 15 (B) | OFF | Below 1 Ω |
| 10 (D) - 7 (E) | MANUAL DOWN | Below 1 Ω |
| 18 (U) - 15 (B) | MANUAL DOWN | Below 1 Ω |
| 1 (AUTO) - 7 (E) | AUTO DOWN | Below 1 Ω |
| 10 (D) - 7 (E) | AUTO DOWN | Below 1 Ω |
| 18 (U) - 15 (B) | AUTO DOWN | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| 15 (B) - 12 (U) | UP | Below 1 Ω |
| 7 (E) - 10 (D) | UP | Below 1 Ω |
| 7 (E) - 12 (U) | OFF | Below 1 Ω |
| 7 (E) - 10 (D) | OFF | Below 1 Ω |
| 7 (E) - 12 (U) | DOWN | Below 1 Ω |
| 15 (B) - 10 (D) | DOWN | Below 1 Ω |
| *a | Component without harness connected (Power Window Regulator Master Switch Assembly) |
![]() |
Check that the LED illuminates.
Apply auxiliary battery voltage to the power window regulator master switch assembly and check that the LED illuminates.
| Measurement Condition | Specified Condition |
| Auxiliary battery positive (+) → Terminal 6 (LED) Auxiliary battery negative (-) → Terminal 7 (E) | LED illuminates |
| *a | Component without harness connected (Power Window Regulator Master Switch Assembly) |