DTC P3004-803 High Voltage Power Resource |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P3004 | 803 | High-voltage circuit malfunctions between the HV battery and inverter with converter assembly. When the power switch is on (READY), both "VLVoltage before Boosting" and "VH-Voltage after Boosting" drop abnormally. The EV electric battery fuse is blown, the service plug grip is removed, SMRB or SMRG remains open, or the highvoltage cable has an open circuit. (1 trip detection logic) |
|
| DTC No. | Data List |
| P3004-803 |
|
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs (including pending DTCs) are output.
| Result | Proceed to |
| Only P3004-803 is output or P3004-803 and DTCs other than the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| P0A95-123 is also output. | C |
| DTC No. | Relevant Diagnosis |
| P0A1A-151, 155, 156, 658, 659 | Generator Control Module |
| P0A1B-164, 193, 512, 661, 786 | Drive Motor "A" Control Module |
| P0A1D-148 | Hybrid Powertrain Control Module |
| P0A78-266, 267, 586 | Drive Motor "A" Inverter Performance |
| P0A94-442 | DC/DC Converter Performance |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P2511-149 | ECM/PCM Power Relay Sensor Circuit Intermittent |
| P3004-131, 132 | High Voltage Power Resource |
| P324E-788 | MG-ECU Power Relay Intermittent Circuit |
| U0110 (all INF codes)*1 | Lost Communication with Drive Motor Control Module "A" |
Turn the ignition switch off.
|
| ||||
|
| ||||
| A | |
| 2.CLEAR DTC |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read and record the DTCs and freeze frame data.
Clear DTCs and freeze frame data.
Turn the ignition switch off.
| NEXT | |
| 3.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (READY).
Ensure the safety of the areas in front and at the back of the vehicle.
Move the shift lever to D and depress both the accelerator pedal and brake pedal at the same time.
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P3004-803 is output, or no DTCs are output. | A |
| Ignition switch is not turned on (READY) and P3004- 131 is output. | B |
Turn the ignition switch off.
|
| ||||
| A | |
| 4.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR) |
![]() |
Check the connector connections and contact pressure of the relevant terminals for the power management control ECU connectors (Click here).
|
| ||||
| OK | |
| 5.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY) |
Check that the service plug grip is not installed.
Disconnect connector G57 from the power management control ECU.
Remove the No. 1 hybrid vehicle battery cover panel LH .
Disconnect connector M40 from the hybrid battery junction block assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| G57-4 (SMRB) - M40-1 (SMRB) | Ignition switch off | Below 1 Ω |
| G57-2 (SMRG) - M40-3 (SMRG) | Ignition switch off | Below 1 Ω |
| *a | Rear view of wire harness connector (to Power Management Control ECU) |
| *b | Rear view of wire harness connector (to Hybrid Battery Junction Block Assembly) |
Connect hybrid battery junction block assembly connector.
Install the No. 1 hybrid vehicle battery cover panel LH.
Connect the power management control ECU connector.
|
| ||||
| OK | ||
| ||