CAN COMMUNICATION SYSTEM > TERMINALS OF ECU |
| CAN JUNCTION CONNECTOR LH |
Check the CAN junction connector LH (instrument panel wire side) (for V bus).
Connection diagram

| *a | Front view of wire harness connector (to CAN Junction Connector LH (Instrument Panel Wire Side)) | *b | to Main Body ECU (Multiplex Network Body ECU) (for V Bus) |
| *c | to Power Steering ECU Assembly (for V Bus) | *d | to DLC3 |
| *e | to CAN Junction Connector RH (for V Bus) | *f | to Power Management Control ECU (for V Bus) |
Check the connection diagram of the components which are connected to the CAN junction connector LH.
| Terminal No. (Symbol) | Wiring Color | Connected to |
| G71-1 (CANH) | R | Main body ECU (Multiplex network body ECU) (for V bus) |
| G71-12 (CANL) | W | |
| G71-2 (CANH) | LG | Power steering ECU assembly (for V bus) |
| G71-13 (CANL) | W | |
| G71-3 (CANH) | GR | DLC3 |
| G71-14 (CANL) | W | |
| G71-4 (CANH) | SB | CAN junction connector RH (for V bus) |
| G71-15 (CANL) | W | |
| G71-5 (CANH) | BE | Power management control ECU (for V bus) |
| G71-16 (CANL) | W |
Check the CAN junction connector LH (engine room main wire side) (for V bus).
Connection diagram

| *a | Front view of wire harness connector (to CAN Junction Connector LH (Engine Room Main Wire Side)) | *b | to ECM (for V Bus) |
| *c | to Brake Booster with Master Cylinder Assembly (Skid Control ECU) (for V Bus) | - | - |
Check the connection diagram of the components which are connected to the CAN junction connector LH.
| Terminal No. (Symbol) | Wiring Color | Connected to |
| A51-9 (CANH) | L | ECM (for V bus) |
| A51-20 (CANL) | W | |
| A51-10 (CANH) | B | Brake booster with master cylinder assembly (Skid control ECU) (for V bus) |
| A51-21 (CANL) | W |
| CAN JUNCTION CONNECTOR RH |
Check the CAN junction connector RH (for V bus).
Connection diagram

| *a | Front view of wire harness connector (to CAN Junction Connector RH) | *b | to Spiral Cable with Sensor Sub-assembly (Steering Sensor) (for V Bus) |
| *c | to Smart Key ECU Assembly (Certification ECU) (for V Bus)*1 | *d | to Airbag Sensor Assembly (for V Bus) |
| *e | to Radio and Display Receiver Assembly (for V Bus)*2 | *f | to Combination Meter Assembly (for V Bus) |
| *g | to Air Conditioning Amplifier Assembly (for V Bus) | *h | to CAN Junction Connector LH (for V Bus) |
Check the connection diagram of the components which are connected to the CAN junction connector RH.
| Terminal No. (Symbol) | Wiring Color | Connected to |
| G72-1 (CANH) | P | Spiral cable with sensor sub-assembly (Steering sensor) (for V bus) |
| G72-12 (CANL) | W | |
| G72-3 (CANH) | L | Smart key ECU assembly (Certification ECU) (for V bus)*1 |
| G72-14 (CANL) | W | |
| G72-4 (CANH) | B | Airbag sensor assembly (for V bus) |
| G72-15 (CANL) | W | |
| G72-5 (CANH) | BE | Radio and display receiver assembly (for V bus)*2 |
| G72-16 (CANL) | W | |
| G72-7 (CANH) | G | Combination meter assembly (for V bus) |
| G72-18 (CANL) | W | |
| G72-8 (CANH) | V | Air conditioning amplifier assembly (for V bus) |
| G72-19 (CANL) | W | |
| G72-10 (CANH) | SB | CAN junction connector LH (for V bus) |
| G72-21 (CANL) | W |
| CAN JUNCTION CONNECTOR LH |
Check the CAN junction connector LH (engine room main wire side) (for Sub bus 15).
Connection diagram

| *a | Front view of wire harness connector (to CAN Junction Connector LH (Engine Room Main Wire Side)) | *b | to Brake Booster with Master Cylinder Assembly (Skid Control ECU) (for Sub Bus 15) |
| *c | to ECM (for Sub Bus 15) | - | - |
Check the connection diagram of the components which are connected to the CAN junction connector LH.
| Terminal No. (Symbol) | Wiring Color | Connected to |
| A51-1 (CANH) | L | Brake booster with master cylinder assembly (Skid control ECU) (for Sub bus 15) |
| A51-12 (CANL) | W | |
| A51-3 (CANH) | B | ECM (for Sub bus 15) |
| A51-14 (CANL) | W |
Check the CAN junction connector LH (instrument panel wire side) (for Sub bus 15).
Connection diagram

| *a | Front view of wire harness connector (to CAN Junction Connector LH (Instrument Panel Wire Side)) | *b | to Power Management Control ECU (for Sub Bus 15) |
Check the connection diagram of the components which are connected to the CAN junction connector LH.
| Terminal No. (Symbol) | Wiring Color | Connected to |
| G71-10 (CANH) | R | Power management control ECU (for Sub bus 15) |
| G71-21 (CANL) | W |
| DLC3 |
Disconnect the cable from the negative (-) auxiliary battery terminal.
![]() |
Measure the resistance according to the value(s) in the table below.
| *1 | DLC3 |
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| G4-6 (CANH) - G4-14 (CANL) | GR - W | HIGH-level CAN bus line - LOW-level CAN bus line | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| G4-6 (CANH) - G4-4 (CG) | GR - P | HIGH-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G4-14 (CANL) - G4-4 (CG) | W - P | LOW-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G4-6 (CANH) - G4-16 (BAT) | GR - SB | HIGH-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G4-14 (CANL) - G4-16 (BAT) | W - SB | LOW-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| POWER MANAGEMENT CONTROL ECU |

| *a | Component without harness connected (Power Management Control ECU) | - | - |
Disconnect the cable from the negative (-) auxiliary battery terminal.
![]() |
Disconnect the power management control ECU connectors.
| *A | w/ Smart Key System |
| *B | w/o Smart Key System |
| *a | Rear view of wire harness connector (to Power Management Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| G58-25 (CA1H) - G58-24 (CA1L) | BE - W | HIGH-level CAN bus line - LOW-level CAN bus line | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| G58-25 (CA1H) - G57-6 (E1) | BE - BR | HIGH-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G58-24 (CA1L) - G57-6 (E1) | W - BR | LOW-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G58-25 (CA1H) - G58-7 (AM21)*1 G58-25 (CA1H) - G57-1 (BATT)*2 | BE - B*1 BE - BE*2 | HIGH-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G58-24 (CA1L) - G58-7 (AM21)*1 G58-24 (CA1L) - G57-1 (BATT)*2 | W - B*1 W - BE*2 | LOW-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| G58-31 (CA3P) - G58-30 (CA3N) | R - W | HIGH-level CAN bus line - LOW-level CAN bus line | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| G58-31 (CA3P) - G57-6 (E1) | R - BR | HIGH-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G58-30 (CA3N) - G57-6 (E1) | W - BR | LOW-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G58-31 (CA3P) - G58-7 (AM21)*1 G58-31 (CA3P) - G57-1 (BATT)*2 | R - B*1 R - BE*2 | HIGH-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G58-30 (CA3N) - G58-7 (AM21)*1 G58-30 (CA3N) - G57-1 (BATT)*2 | W - B*1 W - BE*2 | LOW-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| ECM |

| *a | Component without harness connected (ECM) | - | - |
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the ECM connectors.

| *a | Front view of wire harness connector (to ECM) | - | - |
Measure the resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| A40-13 (CANH) - A40-26 (CANL) | L - W | HIGH-level CAN bus line - LOW-level CAN bus line | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| A40-13 (CANH) - C10-16 (E1) | L - W-B | HIGH-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| A40-26 (CANL) - C10-16 (E1) | W - W-B | LOW-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| A40-13 (CANH) - A40-1 (BATT) | L - Y | HIGH-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| A40-26 (CANL) - A40-1 (BATT) | W - Y | LOW-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| A40-12 (CANP) - A40-25 (CANN) | B - W | HIGH-level CAN bus line - LOW-level CAN bus line | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| A40-12 (CANP) - C10-16 (E1) | B - W-B | HIGH-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| A40-25 (CANN) - C10-16 (E1) | W - W-B | LOW-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| A40-12 (CANP) - A40-1 (BATT) | B - Y | HIGH-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| A40-25 (CANN) - A40-1 (BATT) | W - Y | LOW-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| BRAKE BOOSTER WITH MASTER CYLINDER ASSEMBLY (SKID CONTROL ECU) |

| *a | Component without harness connected (Brake Booster with Master Cylinder Assembly (Skid Control ECU)) | - | - |
Disconnect the cable from the negative (-) auxiliary battery terminal.
![]() |
Disconnect the brake booster with master cylinder assembly (skid control ECU) connector.
| *a | Front view of wire harness connector (to Brake Booster with Master Cylinder Assembly (Skid Control ECU)) |
Measure the resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| A41-37 (CA1H) - A41-38 (CA1L) | B - W | HIGH-level CAN bus line - LOW-level CAN bus line | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| A41-37 (CA1H) - A41-28 (GND) | B - W-B | HIGH-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| A41-38 (CA1L) - A41-28 (GND) | W - W-B | LOW-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| A41-37 (CA1H) - A41-14 (BI) | B - W | HIGH-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| A41-38 (CA1L) - A41-14 (BI) | W - W | LOW-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| A41-35 (CA2H) - A41-34 (CA2L) | L - W | HIGH-level CAN bus line - LOW-level CAN bus line | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| A41-35 (CA2H) - A41-28 (GND) | L - W-B | HIGH-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| A41-34 (CA2L) - A41-28 (GND) | W - W-B | LOW-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| A41-35 (CA2H) - A41-14 (BI) | L - W | HIGH-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| A41-34 (CA2L) - A41-14 (BI) | W - W | LOW-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| AIRBAG SENSOR ASSEMBLY |

| *a | Component without harness connected (Airbag Sensor assembly) | - | - |
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the airbag sensor assembly connector.

| *1 | DLC3 | - | - |
| *a | Front view of wire harness connector (to Airbag Sensor Assembly) | - | - |
Measure the resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| G18-13 (CANH) - G18-22 (CANL) | B - W | HIGH-level CAN bus line - LOW-level CAN bus line | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| G18-13 (CANH) - G18-25 (E1) | B - W-B | HIGH-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G18-22 (CANL) - G18-25 (E1) | W - W-B | LOW-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G18-13 (CANH) - G4-16 (BAT) | B - SB | HIGH-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G18-22 (CANL) - G4-16 (BAT) | W - SB | LOW-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) |

| *a | Component without harness connected (Main Body ECU (Multiplex Network Body ECU)) | - | - |
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the main body ECU (multiplex network body ECU) connectors.

| *1 | DLC3 | - | - |
| *a | Front view of wire harness connector (to Main Body ECU (Multiplex Network Body ECU)) | - | - |
Measure the resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| G59-14 (CANH) - G59-13 (CANL) | R - W | HIGH-level CAN bus line - LOW-level CAN bus line | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| G59-14 (CANH) - G4-4 (CG) | R - P | HIGH-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G59-13 (CANL) - G4-4 (CG) | W - P | LOW-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G59-14 (CANH) - G4-16 (BAT) | R - SB | HIGH-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G59-13 (CANL) - G4-16 (BAT) | W - SB | LOW-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| SPIRAL CABLE WITH SENSOR SUB-ASSEMBLY (STEERING SENSOR) |
Disconnect the cable from the negative (-) auxiliary battery terminal.
![]() |
Disconnect the spiral cable with sensor sub-assembly (steering sensor) connector.
| *a | Front view of wire harness connector (to Spiral Cable with Sensor Sub-assembly (Steering Sensor)) |
Measure the resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| G30-4 (CANH) - G30-3 (CANL) | P - W | HIGH-level CAN bus line - LOW-level CAN bus line | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| G30-4 (CANH) - G30-2 (ESS) | P - W-B | HIGH-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G30-3 (CANL) - G30-2 (ESS) | W - W-B | LOW-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G30-4 (CANH) - G30-6 (BAT) | P - B | HIGH-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G30-3 (CANL) - G30-6 (BAT) | W - B | LOW-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| POWER STEERING ECU ASSEMBLY |

| *a | Component without harness connected (Power Steering ECU Assembly) | - | - |
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the power steering ECU assembly connectors.

| *a | Front view of wire harness connector (to Power Steering ECU Assembly) | - | - |
Measure the resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| G6-7 (CANH) - G6-8 (CANL) | LG - W | HIGH-level CAN bus line - LOW-level CAN bus line | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| G6-7 (CANH) - A33-2 (PGND) | LG - W-B | HIGH-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G6-8 (CANL) - A33-2 (PGND) | W - W-B | LOW-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G6-7 (CANH) - A33-1 (PIG) | LG - W | HIGH-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G6-8 (CANL) - A33-1 (PIG) | W - W | LOW-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| SMART KEY ECU ASSEMBLY (CERTIFICATION ECU) (w/ SMART KEY SYSTEM) |

| *a | Component without harness connected (Smart Key ECU Assembly (Certification ECU)) | - | - |
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the smart key ECU assembly (certification ECU) connector.

| *a | Front view of wire harness connector (to Smart Key ECU Assembly (Certification ECU)) | - | - |
Measure the resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| G54-1 (CANH) - G54-2 (CANL) | L - W | HIGH-level CAN bus line - LOW-level CAN bus line | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| G54-1 (CANH) - G55-1 (E) | L - W-B | HIGH-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G54-2 (CANL) - G55-1 (E) | W - W-B | LOW-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G54-1 (CANH) - G54-5 (+B) | L - BE | HIGH-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G54-2 (CANL) - G54-5 (+B) | W - BE | LOW-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| COMBINATION METER ASSEMBLY |

| *a | Component without harness connected (Combination Meter Assembly) | - | - |
Disconnect the cable from the negative (-) auxiliary battery terminal.
![]() |
Disconnect the combination meter assembly connector.
| *a | Front view of wire harness connector (to Combination Meter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| G1-31 (CANH) - G1-32 (CANL) | G - W | HIGH-level CAN bus line - LOW-level CAN bus line | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| G1-31 (CANH) - G1-20 (ET) | G - BR | HIGH-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G1-32 (CANL) - G1-20 (ET) | W - BR | LOW-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G1-31 (CANH) - G1-1 (B) | G - L | HIGH-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G1-32 (CANL) - G1-1 (B) | W - L | LOW-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| AIR CONDITIONING AMPLIFIER ASSEMBLY |

| *a | Component without harness connected (Air Conditioning Amplifier Assembly) | - | - |
Disconnect the cable from the negative (-) auxiliary battery terminal.
![]() |
Disconnect the air conditioning amplifier assembly connector.
| *a | Front view of wire harness connector (to Air Conditioning Amplifier Assembly) | - | - |
Measure the resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| G34-11 (CANH) - G34-12 (CANL) | V - W | HIGH-level CAN bus line - LOW-level CAN bus line | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| G34-11 (CANH) - G34-14 (GND) | V - W-B | HIGH-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G34-12 (CANL) - G34-14 (GND) | W - W-B | LOW-level CAN bus line - Ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G34-11 (CANH) - G34-21 (B) | V - BE | HIGH-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G34-12 (CANL) - G34-21 (B) | W - BE | LOW-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| RADIO AND DISPLAY RECEIVER ASSEMBLY (FOR RADIO AND DISPLAY TYPE) |

| *a | Component without harness connected (Radio and Display Receiver Assembly) | - | - |
Disconnect the cable from the negative (-) battery terminal.
Disconnect the radio and display receiver assembly connectors.

| *a | Front view of wire harness connector (to Radio and Display Receiver Assembly) | - | - |
Measure the resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| G78-9 (CANH) - G78-10 (CANL) | BE - W | HIGH-level CAN bus line - LOW-level CAN bus line | Cable disconnected from negative (-) battery terminal | 54 to 69 Ω |
| G78-9 (CANH) - G76-7 (GND1) | BE - BR | HIGH-level CAN bus line - Ground | Cable disconnected from negative (-) battery terminal | 200 Ω or higher |
| G78-10 (CANL) - G76-7 (GND1) | W - BR | LOW-level CAN bus line - Ground | Cable disconnected from negative (-) battery terminal | 200 Ω or higher |
| G78-9 (CANH) - G76-4 (+B1) | BE - B | HIGH-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher |
| G78-10 (CANL) - G76-4 (+B1) | W - B | LOW-level CAN bus line - Battery positive (+) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher |