DTC P0A38-257 Generator Temperature Sensor Circuit Low |
DTC P0A39-259 Generator Temperature Sensor Circuit High |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A38 | 257 | Short to GND or short in the generator temperature sensor circuit (1 trip detection logic) |
|
| P0A39 | 259 | Open or short to +B in the generator temperature sensor circuit (1 trip detection logic) |
| DTC No. | Data List |
| P0A38-257 | Motor Temp No2 |
| P0A39-259 |
| Displayed Temperature | Malfunction |
| -40°C (-40°F) | Open circuit or short to +B |
| 215°C (419°F) | Short circuit or short to GND |

| 1.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR) |
![]() |
Check the connector connections and contact pressure of the relevant terminals for the power management control ECU connectors (Click here).
|
| ||||
| OK | |
| 2.READ VALUE USING TECHSTREAM (MOTOR TEMP NO2) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Motor Temp No2.
Read the Data List.
| Result | Proceed to |
| -40°C (-40°F) | A |
| 215°C (419°F) | B |
| Same as actual temperature | C |
Turn the ignition switch off.
|
| ||||
|
| ||||
| A | |
| 3.READ VALUE USING TECHSTREAM (CHECK FOR OPEN) |
![]() |
Disconnect the generator temperature sensor connector.
![]() |
Connect terminals 4 (GMT) and 8 (GMTG) of vehicle side connector C24 of the generator temperature sensor.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Motor Temp No2.
Read the Data List.
| Tester Display | Condition | Specified Condition |
| Motor Temp No2 | Terminals GMT and GMTG connected. Ignition switch ON (IG) | 215°C (419°F) |
| *a | Front view of wire harness connector (to Generator Temperature Sensor) |
Turn the ignition switch off.
Connect the generator temperature sensor connector.
|
| ||||
| OK | ||
| ||
| 4.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - GENERATOR TEMPERATURE SENSOR) |
![]() |
Connect terminals 26 (GMT) and 27 (GMTG) of connector A38 of the power management control ECU.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Motor Temp No2.
Read the Data List.
| Tester Display | Condition | Specified Condition |
| Motor Temp No2 | Terminals GMT and GMTG connected. Ignition switch ON (IG) | 215°C (419°F) |
| *a | Component with harness connected (Power Management Control ECU) |
Turn the ignition switch off.
|
| ||||
| OK | ||
| ||
| 5.READ VALUE USING TECHSTREAM (CHECK FOR SHORT) |
![]() |
Disconnect the generator temperature sensor connector.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Motor Temp No2.
Read the Data List.
| Tester Display | Condition | Specified Condition |
| Motor Temp No2 | Ignition switch ON (IG) | -40°C (-40°F) |
Turn the ignition switch off.
Connect the generator temperature sensor connector.
|
| ||||
| OK | ||
| ||
| 6.CHECK HARNESS AND CONNECTOR (GENERATOR TEMPERATURE SENSOR - POWER MANAGEMENT CONTROL ECU) |
Disconnect the generator temperature sensor connector.
Disconnect connector A38 from the power management control ECU.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C24-4 (GMT) - A38-26 (GMT) | Ignition switch off | Below 1 Ω |
| C24-8 (GMTG) - A38-27 (GMTG) | Ignition switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C24-4 (GMT) or A38-26 (GMT) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| C24-8 (GMTG) or A38-27 (GMTG) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector (to Generator Temperature Sensor) |
| *b | Rear view of wire harness connector (to Power Management Control ECU) |
Connect the power management control ECU connector.
Connect the generator temperature sensor connector.
|
| ||||
| OK | ||
| ||