DTC P0A4B-253 Generator Position Sensor Circuit |
DTC P0A4C-513 Generator Position Sensor Circuit Range / Performance |
DTC P0A4D-255 Generator Position Sensor Circuit Low |

| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A4B | 253 | Interphase short in the generator resolver circuit. Short circuit between signal lines of generator resolver phases is electrically detected. (1 trip detection logic) |
|
| P0A4C | 513 | Generator resolver output signal is out of the normal range (amplitude is too large or too small). (1 trip detection logic) | |
| P0A4D | 255 | Open or short in the generator resolver circuit. Generator resolver signal is out of the normal range (signal output amplitude is extremely small). (1 trip detection logic) |
| Related DTCs | P0A4B (INF 253): Short circuit between phases P0A4C (INF 513): Range check P0A4D (INF 255): Circuit discontinuity / short circuit |
| Required sensors / components | Generator resolver |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| TMC's intellectual property | - |
| Generator resolver | DTC P0A4B (INF 253) is not detected DTC P0A4C (INF 513) is not detected DTC P0A4D (INF 255) is not detected |


| 1.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
![]() |
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-12 (GRFG) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-7 (GSN) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-8 (GSNG) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-10 (GCS) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-9 (GCSG) - Body ground | Ignition switch ON (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 3.CHECK GENERATOR RESOLVER |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) - C28-12 (GRFG) | Ignition switch off | 7.1 to 21.6 Ω |
| C28-7 (GSN) - C28-8 (GSNG) | Ignition switch off | 13.7 to 34.5 Ω |
| C28-10 (GCS) - C28-9 (GCSG) | Ignition switch off | 12.8 to 32.4 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) or C28-12 (GRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-7 (GSN) or C28-8 (GSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-10 (GCS) or C28-9 (GCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-2 (MRFG) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-3 (MSN) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-4 (MSNG) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-6 (MCS) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-5 (MCSG) - Body ground | Ignition switch ON (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 5.CHECK MOTOR RESOLVER |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) - C28-2 (MRFG) | Ignition switch off | 7.1 to 21.6 Ω |
| C28-3 (MSN) - C28-4 (MSNG) | Ignition switch off | 13.7 to 34.5 Ω |
| C28-6 (MCS) - C28-5 (MCSG) | Ignition switch off | 12.8 to 32.4 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) or C28-2 (MRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-3 (MSN) or C28-4 (MSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-6 (MCS) or C28-5 (MCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 6.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 7.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | ||
| ||
| 8.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 9.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
![]() |
Disconnect the generator resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) - C24-1 (GRF) | Ignition switch off | Below 1 Ω |
| C28-12 (GRFG) - C24-5 (GRFG) | Ignition switch off | Below 1 Ω |
| C28-7 (GSN) - C24-2 (GSN) | Ignition switch off | Below 1 Ω |
| C28-8 (GSNG) - C24-6 (GSNG) | Ignition switch off | Below 1 Ω |
| C28-10 (GCS) - C24-3 (GCS) | Ignition switch off | Below 1 Ω |
| C28-9 (GCSG) - C24-7 (GCSG) | Ignition switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) or C24-1 (GRF) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-12 (GRFG) or C24-5 (GRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-7 (GSN) or C24-2 (GSN) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-8 (GSNG) or C24-6 (GSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-10 (GCS) or C24-3 (GCS) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-9 (GCSG) or C24-7 (GCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Generator Resolver) |
Connect the generator resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||
| 10.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | |
| 11.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
![]() |
Disconnect the motor resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) - C26-3 (MRF) | Ignition switch off | Below 1 Ω |
| C28-2 (MRFG) - C26-6 (MRFG) | Ignition switch off | Below 1 Ω |
| C28-3 (MSN) - C26-1 (MSN) | Ignition switch off | Below 1 Ω |
| C28-4 (MSNG) - C26-4 (MSNG) | Ignition switch off | Below 1 Ω |
| C28-6 (MCS) - C26-2 (MCS) | Ignition switch off | Below 1 Ω |
| C28-5 (MCSG) - C26-5 (MCSG) | Ignition switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) or C26-3 (MRF) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-2 (MRFG) or C26-6 (MRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-3 (MSN) or C26-1 (MSN) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-4 (MSNG) or C26-4 (MSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-6 (MCS) or C26-2 (MCS) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-5 (MCSG) or C26-5 (MCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Motor Resolver) |
Connect the motor resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||