Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P0C76-523    Hybrid Battery System Discharge Time Too Long

for Preparation Click here


DESCRIPTION

Refer to the description for DTC P0A78-266 .

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0C76
523
The inverter voltage (VH) does not drop during discharge.
(Discharge: Offsetting of the residual voltage pressure in the high-voltage side after ignition switch is turned off)
(1 trip detection logic)
  1. Inverter with converter assembly
  2. Wire harness or connector
  3. Power management control ECU

HINT:
When the ignition switch is turned off from ON (READY), the MG ECU applies current to motor (MG2) in a way that does not generate torque, in order to discharge the residual voltage in the inverter. When the hybrid system is normal, the VH value is almost 0 V after discharge. This DTC will be stored if the VH value is more than the specified value after discharge.


A111758E02


Related Data List 
DTC No.
Data List
P0C76-523
VL-Voltage before Boosting
The following items can be helpful when performing repairs:
Data List
  1. Ready Signal

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0AE6-225 .
Refer to the wiring diagram for DTC P321E-318 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (Click here).

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).

HINT:
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
  1. Turn the ignition switch off and wait for 30 seconds or more.
  2. Turn the ignition switch to ON (READY) and wait for 30 seconds or more.
  3. Turn the ignition switch off and wait for 30 seconds or more.

1.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    Only P0C76-523 is output or P0C76-523 and DTCs other than the ones in the table below are also output.
    A
    Any of the following DTCs are also output.
    B


    DTC No.
    Relevant Diagnosis
    P0A1A-151, 155, 156, 200, 658, 659, 791, 792, 793
    Generator Control Module
    P0A1B-163, 164, 168, 193, 511, 661, 786, 794, 795, 796
    Drive Motor "A" Control Module
    P0A1D-148
    Hybrid Powertrain Control Module
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range/Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range/Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0A78-266, 267
    Drive Motor "A" Inverter Performance
    P0ADC-226
    Hybrid Battery Positive Contactor Control Circuit High
    P0AE0-228
    Hybrid Battery Negative Contactor Control Circuit High
    P0AE7-224
    Hybrid Battery Precharge Contactor Control Circuit High
    P2511-149
    ECM/PCM Power Relay Sensor Circuit Intermittent
    P324E-788
    MG-ECU Power Relay Intermittent Circuit
    U0110 (all INF codes)*1
    Lost Communication with Drive Motor Control Module "A"

    HINT:
    1. *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
    2. P0C76-523 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.

  1. Turn the ignition switch off.



B
GO TO DTC CHART (HYBRID CONTROL SYSTEM) (Click here)
A


2.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    Any of the following DTCs are also output.
    A
    Only P0C76-523 is output or P0C76-523 and DTCs other than the ones in the table below are also output.
    B


    DTC No.
    Relevant Diagnosis
    P0A78-306
    Drive Motor "A" Inverter Performance
    P0A7A-344
    Generator Inverter Performance
    P0A90-251, 509
    Drive Motor "A" Performance
    P0A92-261, 521
    Hybrid Generator Performance

    HINT:
    When the DTCs listed in the table above are also output, there may be a short between the HSDN (MG shut down signal) circuit and power circuit.

  1. Turn the ignition switch off.



B
REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)
A


3.CHECK POWER MANAGEMENT CONTROL ECU
  1. Turn the ignition switch to ON (IG).



    A252924E07
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-31 (HSDN) - G57-6 (E1)
    Ignition switch ON
    Below 4.5 V

    Text in Illustration 
    *a
    Component with harness connected
    (Power Management Control ECU)

  1. Turn the ignition switch off.



NG
Go to step 4
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

4.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A47 from the inverter with converter assembly.

  1. Disconnect connector A39 from the power management control ECU.

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the ignition switch to ON (IG).



    A216755E17
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A47-31 (HSDN) or A39-31 (HSDN) - Body ground
    Ignition switch ON
    Below 1 V

    Text in Illustration 
    *A
    w/ Smart Key System
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)
    *b
    Rear view of wire harness connector
    (to Power Management Control ECU)

    NOTICE:
    Turning the ignition switch to ON (IG) with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (w/ Smart Key System):
    Tester Connection
    Switch Condition
    Specified Condition
    A39-31 (HSDN) - A39-1 (IG2)
    Power switch off
    10 kΩ or higher
    A39-31 (HSDN) - A39-2 (IG2D)
    Power switch off
    10 kΩ or higher
    A39-31 (HSDN) - A39-5 (+B1)
    Power switch off
    10 kΩ or higher
    A39-31 (HSDN) - A39-6 (MREL)
    Power switch off
    10 kΩ or higher
    A47-31 (HSDN) - A47-10 (+B)
    Power switch off
    10 kΩ or higher
    A47-31 (HSDN) - A47-9 (+B2)
    Power switch off
    10 kΩ or higher

    Standard Resistance (w/o Smart Key System):
    Tester Connection
    Switch Condition
    Specified Condition
    A39-31 (HSDN) - A39-1 (IG2)
    Ignition switch off
    10 kΩ or higher
    A39-31 (HSDN) - A39-5 (+B1)
    Ignition switch off
    10 kΩ or higher
    A39-31 (HSDN) - A39-6 (MREL)
    Ignition switch off
    10 kΩ or higher
    A47-31 (HSDN) - A47-10 (+B)
    Ignition switch off
    10 kΩ or higher
    A47-31 (HSDN) - A47-9 (+B2)
    Ignition switch off
    10 kΩ or higher

  1. Connect the inverter with converter assembly connector.

  1. Connect the power management control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.CHECK INVERTER WITH CONVERTER ASSEMBLY

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A47 from the inverter with converter assembly.



    A215652E44
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A47-31 (HSDN) - A47-10 (+B)
    Ignition switch off
    5 kΩ or higher
    A47-31 (HSDN) - A47-9 (+B2)
    Ignition switch off
    5 kΩ or higher

    Text in Illustration 
    *a
    Component without harness connected
    (Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)