1NZ-FXE COOLING > SERVICE DATA |
| Condition | Rod Operation |
| Cold (below approx. 71°C (160°F)) → Warmed up (approx. 80°C (176°F) or more) | Rod gradually extends smoothly as the temperature rises |
| Condition | Specified Condition |
| Approximately 20°C (68°F) | 2.32 to 2.59 kΩ |
| Approximately 80°C (176°F) | 0.310 to 0.326 kΩ |
| Condition | Specified Condition |
| Standard valve opening temperature | 80 to 84°C (176 to 183°F) |
| Standard valve lift | 0.8 mm (0.315 in.) or more at 95°C (203°F) |
| Item | Condition | Specified Condition |
| Cooling fan motor | 20°C (68°F) at 12 V | 12.2 to 15.7 A |
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | Auxiliary battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Auxiliary battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
| Item | Tester Connection | Specified Condition |
| Water filler cap sub-assembly | for brand-new cap | 93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi) |
| for used cap | 78.5 kPa (0.8 kgf/cm2, 11.4 psi) |