Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM

AIR CONDITIONING SYSTEM > DATA LIST / ACTIVE TEST

for Preparation Click here



DATA LIST
Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Connect the Techstream to the DLC3.

  2. Turn the ignition switch to ON (IG).

  3. Turn the Techstream on.

  4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

  5. Check the value(s) by referring to the table below.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Room Temperature Sensor
    Room temperature sensor (cooler thermistor) /
    Min.: -6.50°C (20.30°F)
    Max.: 57.25°C (135.05°F)
    Actual cabin temperature displayed
    -
    Ambient Temp Sensor
    Ambient temperature sensor (thermistor assembly) /
    Min.: -23.30°C (-9.94°F)
    Max.: 65.95°C (150.71°F)
    Actual ambient temperature displayed
    -
    Adjusted Ambient Temp
    Adjusted ambient temperature /
    Min.: -30.80°C (-23.44°F)
    Max.: 50.80°C (123.44°F)
    -
    -
    Evaporator Fin Thermistor
    Evaporator temperature sensor (No. 1 cooler thermistor) /
    Min.: -29.70°C (-21.46°F)
    Max.: 59.55°C (139.19°F)
    Actual evaporator temperature displayed
    -
    Evaporator Target Temp
    Evaporator target temperature /
    Min.: -327.68°C (-557.82°F)
    Max.: 327.67°C (621.81°F)
    Evaporator target temperature displayed
    -
    Solar Sensor (D Side)
    Solar sensor /
    Min.: 0
    Max.: 255
    Solar sensor value increases as brightness increases
    -
    Engine Coolant Temp
    Engine coolant temperature sensor /
    Min.: 1.30°C (34.34°F)
    Max.: 90.55°C (194.99°F)
    Actual engine coolant temperature displayed
    -
    Set Temperature (D Side)
    Set temperature /
    Min.: MAX COLD
    Max.: MAX HOT
    Set temperature displayed
    -
    Blower Motor Speed Level
    Blower motor speed level /
    Min.: 0
    Max.: 31
    Displayed speed level increases in range between 0 and 31 as blower motor speed increases
    -
    Regulator Pressure Sensor
    Air conditioning pressure sensor /
    Min.: -456.68 kPa (-66.2 psi(gauge))
    Max.: 3294.37 kPa (478 psi(gauge))
    Actual pressure displayed
    -
    Air Mix Servo Targ Pulse(D)
    No. 1 air conditioning radiator damper servo sub-assembly (air mix) target pulse /
    Min.: 128
    Max.: 383
    MAX. COLD: 257 (pulse)
    MAX. HOT: 173 (pulse)
    -
    Air Mix Servo Actual Pulse(D)
    No. 1 air conditioning radiator damper servo sub-assembly (air mix) actual pulse /
    Min.: 128
    Max.: 383
    MAX. COLD: 257 (pulse)
    MAX. HOT: 173 (pulse)
    -
    Air Outlet Servo Pulse (D)
    No. 2 air conditioning radiator damper servo sub-assembly (air outlet) target pulse /
    Min.: 128
    Max.: 383
    FACE: 267 (pulse)
    B/L: 250 (pulse)
    FOOT: 227 (pulse)
    FOOT/DEF: 220 (pulse)
    DEF: 206 (pulse)
    -
    Air Outlet Servo Actu Pulse(D)
    No. 2 air conditioning radiator damper servo sub-assembly (air outlet) actual pulse /
    Min.: 128
    Max.: 383
    FACE: 267 (pulse)
    B/L: 250 (pulse)
    FOOT: 227 (pulse)
    FOOT/DEF: 220 (pulse)
    DEF: 206 (pulse)
    -
    Air Inlet Damper Targ Pulse
    No. 1 blower damper servo sub-assembly (air inlet) target pulse /
    Min.: 128
    Max.: 383
    RECIRCULATION: 287 (pulse)
    FRESH: 254 (pulse)
    -
    Air Inlet Damper Actual Pulse
    No. 1 blower damper servo sub-assembly (air inlet) actual pulse /
    Min.: 128
    Max.: 383
    RECIRCULATION: 287 (pulse)
    FRESH: 254 (pulse)
    -
    Electric Heater Count*1
    Maximum heater operation level /
    Min.: 0
    Max.: 3
    Maximum possible operation level of quick heater assembly displayed
    -
    Electric Heater Active Level*1
    Actual heater operation level /
    Min.: 0
    Max.: 3
    Actual operation level of quick heater assembly displayed
    -
    Compressor Speed
    Compressor speed /
    Min.: 0 rpm
    Max.: 65535 rpm
    Actual compressor rotation speed displayed
    -
    Compressor Target Speed
    Compressor target speed /
    Min.: 0 rpm
    Max.: 65535 rpm
    Compressor target rotation speed displayed
    -
    Shift Set Temperature
    Shift set temperature /
    2C decr, 1C decr, Normal, 1C incr, 2C incr
    Customized value displayed
    -
    Compressor Mode
    Compressor mode /
    Auto or Manual
    Customized value displayed
    -
    Noise and Vibration Reduction
    Noise and vibration reduction /
    OFF or ON
    Customized value displayed
    -
    ECO MODE Cancel
    ECO MODE Cancel /
    OFF or ON
    Customized value displayed
    -
    ECO Switch
    ECO mode switch (eco switch assembly) /
    OFF or ON
    ECO mode switch (eco switch assembly) operated: ON
    (when switch is pressed)
    -
    ECO mode switch (eco switch assembly) not operated: OFF
    (when switch is not pressed)
    -
    Refrigerant Shortage Check
    Refrigerant shortage check /
    ON or OFF
    Customized value displayed
    -
    Fan speed increment control
    Fan speed increment control /
    Slow, Normal, Fast
    Customized value displayed
    -
    Foot/DEF Auto Mode
    Foot/DEF Auto Mode /
    ON or OFF
    Customized value displayed
    -
    Foot/DEF Auto Blow Up
    Foot/DEF Auto blower speed increase /
    ON or OFF
    Customized value displayed
    -
    Ambient Temperature Shift
    Ambient temperature shift /
    3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr
    Customized value displayed
    -
    Pls Servo Test Sts
    Pulse servo motor test status/
    Wait, Move, Comp, Error, Stop
    Pulse servo motor test status
    -
    Compressor Drive Check
    Compressor drive check /
    OK or NG
    NG: Compressor does not drive
    OK: Compressor drives
    -
    Number of Trouble Codes
    Number of trouble codes /
    Min.: 0
    Max.: 255
    Number of DTCs displayed
    -

    1. *1 w/ Quick Heater Assembly


ACTIVE TEST
Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
  1. Connect the Techstream to the DLC3.

  2. Turn the ignition switch to ON (IG).

  3. Turn the Techstream on.

  4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

  5. Check the operation by referring to the table below.

    Air Conditioner 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Blower Motor
    Blower motor with fan sub-assembly
    Min.: 0, Max.: 31
    -
    Compressor Target Speed
    Compressor with motor assembly
    Min.: 0, Max.: 7500
    -
    Defogger Relay (Rear)
    Defogger relay
    OFF, ON
    -
    Electrical Fan
    Electrical fan
    OFF, ON
    -
    Heater Active Level*1
    Quick heater assembly
    Min.: 0, Max.: 3
    -
    Air Mix Servo Targ Pulse(D)
    No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse
    Min.: 128, Max.: 383
    Operates between 173 and 257 pulses
    Air Outlet Servo Pulse (D)
    No. 2 air conditioning radiator damper servo sub-assembly (air outlet) pulse
    Min.: 128, Max.: 383
    Operates between 206 and 267 pulses
    Air Inlet Damper Targ Pulse
    No. 1 blower damper servo sub-assembly (air inlet) pulse
    Min.: 128, Max.: 383
    Operates between 254 and 287 pulses

    1. *1 w/ Quick Heater Assembly