Home › Engine / Hybrid System › 1NZ-FXE EMISSION CONTROL › CANISTER

CANISTER > REMOVAL

for Preparation Click here



1. REMOVE CHARCOAL CANISTER ASSEMBLY


    A267667E02
  1. Disconnect the connector from the charcoal canister leak detection pump sub-assembly.

  1. Disconnect the air line tube.

    1. Push the air line tube firmly toward the charcoal canister side.

    2. Pull the air line tube as shown in the illustration.

    3. Pull out the air line tube.
      Text in Illustration 
      *1
      Retainer
      *2
      Air Line Tube
      V100136
      Pull

      NOTICE:

      1. A275787E01
        Remove any dirt or foreign matter on the tube connector before performing this work.
        Text in Illustration 
        *1
        Tube Connector
        *2
        O-ring
        *3
        Retainer
        *4
        Pipe (Leak Detection Pump Sub-Assembly)
      2. Do not allow any scratches or foreign matter to get on the parts when disconnecting them as the tube connector has an O-ring that seals the pipe.
      3. Perform this work by hand. Do not use any tools.
      4. Do not forcibly bend, twist or turn the air line tube.
      5. Protect the disconnected parts by covering them with plastic bags after disconnecting the air line tube.
      6. If the tube connector and pipe are stuck, push and pull on them to release.



    A267666
  1. Disconnect the purge line hose.



    A269228E01
  1. Disconnect the vent line tube.

    1. Push the vent line tube firmly toward the charcoal canister side.

    2. Pinch the vent line tube as shown in the illustration.

    3. Pull out the vent line tube.
      Text in Illustration 
      *1
      Retainer
      *2
      Vent Line Tube
      V100135
      Pinch
      V100136
      Pull

      NOTICE:

      1. A275787E01
        Remove any dirt or foreign matter on the tube connector before performing this work.
        Text in Illustration 
        *1
        Tube Connector
        *2
        O-ring
        *3
        Retainer
        *4
        Pipe (Charcoal Canister Assembly)
      2. Do not allow any scratches or foreign matter to get on the parts when disconnecting them as the tube connector has an O-ring that seals the pipe.
      3. Perform this work by hand. Do not use any tools.
      4. Do not forcibly bend, twist or turn the air line tube.
      5. Protect the disconnected parts by covering them with plastic bags after disconnecting the air line tube.
      6. If the tube connector and pipe are stuck, push and pull on them to release.



    A267665
  1. Remove the 3 bolts and charcoal canister assembly.



2. REMOVE CHARCOAL CANISTER BASE BRACKET


    A267662
  1. Remove the 4 bolts, clamp and charcoal canister base bracket.



3. REMOVE CHARCOAL CANISTER SUPPORT BRACKET


    A267663
  1. Remove the 2 bolts, clamp and charcoal canister support bracket.



4. REMOVE CHARCOAL CANISTER PROTECTOR


    A276441
  1. Remove the clip and charcoal canister protector.



5. REMOVE NO. 1 CHARCOAL CANISTER FILTER


    A269226E01
  1. Disengage the 2 claws and remove the cap.

  1. Disconnect the vent hose.

    1. Push the vent hose firmly toward the charcoal canister side.

    2. Pinch the vent hose as shown in the illustration.

    3. Pull out the vent hose.
      Text in Illustration 
      *1
      Retainer
      *2
      Vent Hose
      V100135
      Pinch
      V100136
      Pull

      NOTICE:

      1. A275787E01
        Remove any dirt or foreign matter on the tube connector before performing this work.
        Text in Illustration 
        *1
        Tube Connector
        *2
        O-ring
        *3
        Retainer
        *4
        Pipe (Charcoal Canister Assembly)
      2. Do not allow any scratches or foreign matter to get on the parts when disconnecting them as the tube connector has an O-ring that seals the pipe.
      3. Perform this work by hand. Do not use any tools.
      4. Do not forcibly bend, twist or turn the vent hose.
      5. Protect the disconnected parts by covering them with plastic bags after disconnecting the vent hose.
      6. If the tube connector and pipe are stuck, push and pull on them to release.



6. REMOVE LEAK DETECTION PUMP SUB-ASSEMBLY
  1. Before removing the leak detection pump sub-assembly, clean the canister by blowing air into it to ensure that the canister is free of foreign matter.

    NOTICE:
    1. Make sure to clean the canister using air only.
    2. Do not use gasoline, thinners or solvents.



    A267657E01
  1. While disengaging the 2 claws as shown in the illustration, push the leak detection pump sub-assembly upwards using a screwdriver to remove it.
    Text in Illustration 
    *1
    Protective Tape

    HINT:
    Tape the screwdriver tip before use.



  1. Check if the canister contains foreign matter such as mud or water.



      A259514
    1. Visually check that the inside of the canister is free of foreign matter.

    2. Hold the canister upside down to make sure that the canister is free of foreign matter.
      If the canister contains foreign matter, replace the canister.