DTC P0A78-121 Drive Motor "A" Inverter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A78 | 121 | Motor inverter overvoltage signal detection (overvoltage due to system malfunction) Overvoltage is detected after boosting. A malfunction is detected in any of the motor components (motor inverter, motor, MG ECU, etc.). (1 trip detection logic) |
|
| DTC No. | Data List |
| P0A78-121 | VH-Voltage after Boosting |
| Related DTCs | P0A78 (INF 121): OVH detection (Over voltage malfunction) |
| Required sensors / components | Motor inverter |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| TMC's intellectual property | - |
| Power management control ECU | DTC P0A78 (INF 121) is not detected |

| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P0A78-121 is set before any of the DTCs in the table below are set. | A |
| Any of the DTCs including pending DTCs in the table below are set before P0A78-121 is set. | B |
| DTC No. | Relevant Diagnosis |
| P0A9C-123 | Hybrid Battery Temperature Sensor "A" Range / Performance |
| P0A9D-123 | Hybrid Battery Temperature Sensor "A" Circuit Low |
| P0A9E-123 | Hybrid Battery Temperature Sensor "A" Circuit High |
| P0AC0-123 | Hybrid Battery Pack Current Sensor Circuit Range / Performance |
| P0AC1-123 | Hybrid Battery Pack Current Sensor Circuit Low |
| P0AC2-123 | Hybrid Battery Pack Current Sensor Circuit High |
| P0AC6-123 | Hybrid Battery Temperature Sensor "B" Range / Performance |
| P0AC7-123 | Hybrid Battery Temperature Sensor "B" Circuit Low |
| P0AC8-123 | Hybrid Battery Temperature Sensor "B" Circuit High |
| P0ACB-123 | Hybrid Battery Temperature Sensor "C" Range / Performance |
| P0ACC-123 | Hybrid Battery Temperature Sensor "C" Circuit Low |
| P0ACD-123 | Hybrid Battery Temperature Sensor "C" Circuit High |
| P0AFC-123 | Hybrid Battery Pack Sensor Module |
| P3011-123, P3012-123, P3013-123, P3014-123, P3015-123, P3016-123, P3017-123, P3018-123, P3019-123, P3020-123 | Battery Block # Becomes Weak |
| P3065-123 | Hybrid Battery Temperature Sensor Range / Performance Stuck "A" |
| P308A-123 | Hybrid Battery Voltage Sensor All Circuits Low |
Turn the ignition switch off.
|
| ||||
| A | |
| 2.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| Only P0A78-121 is output, or DTCs other than the ones in the table below are also output. | A |
| Any of the following DTCs including pending DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B (all INF codes)*1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A60 (all INF codes)*1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes)*1 | Drive Motor "A" Phase W Current |
| P0A72 (all INF codes)*1 | Generator Phase V Current |
| P0A75 (all INF codes)*1 | Generator Phase W Current |
| P0A78-113, 128, 266, 267, 279, 284, 286, 287, 306, 503, 504, 505, 506, 565, 586, 806, 807, 808 | Drive Motor "A" Inverter Performance |
| P0A7A-122, 130, 322, 324, 325, 344, 517, 518, 809, 810, 811 | Generator Inverter Performance |
| P0A90-509 | Drive Motor "A" Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0A93-346 | Inverter Cooling System Performance |
| P0A94-172, 442, 547, 548, 549, 553, 554, 555, 556, 557, 585, 587, 589, 590 | DC / DC Converter Performance |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0C73-776 | Motor Electronics Coolant Pump "A" Control Performance |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P3004-803 | High Voltage Power Resource |
| P314A-828 | Inverter Coolant Pump Speed Signal |
Turn the ignition switch off.
|
| ||||
| A | |
| 3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
![]() |
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-12 (GRFG) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-7 (GSN) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-8 (GSNG) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-10 (GCS) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-9 (GCSG) - Body ground | Ignition switch ON (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 5.CHECK GENERATOR RESOLVER |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) - C28-12 (GRFG) | Ignition switch off | 7.1 to 21.6 Ω |
| C28-7 (GSN) - C28-8 (GSNG) | Ignition switch off | 13.7 to 34.5 Ω |
| C28-10 (GCS) - C28-9 (GCSG) | Ignition switch off | 12.8 to 32.4 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) or C28-12 (GRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-7 (GSN) or C28-8 (GSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-10 (GCS) or C28-9 (GCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 6.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-2 (MRFG) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-3 (MSN) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-4 (MSNG) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-6 (MCS) - Body ground | Ignition switch ON (IG) | Below 1 V |
| C28-5 (MCSG) - Body ground | Ignition switch ON (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 7.CHECK MOTOR RESOLVER |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) - C28-2 (MRFG) | Ignition switch off | 7.1 to 21.6 Ω |
| C28-3 (MSN) - C28-4 (MSNG) | Ignition switch off | 13.7 to 34.5 Ω |
| C28-6 (MCS) - C28-5 (MCSG) | Ignition switch off | 12.8 to 32.4 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) or C28-2 (MRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-3 (MSN) or C28-4 (MSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-6 (MCS) or C28-5 (MCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 8.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE (FOR MG1) CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Remove the inverter cover from the inverter with converter assembly.
![]() |
Check that the bolts for the motor cable (for MG1) are tightened to the specified torque, the motor cable (for MG1) is connected securely, and there are no contact problems.
Disconnect the motor cable (for MG1) from the inverter with converter assembly.
Check for arc marks at the terminals for the motor cable (for MG1).
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable (for MG1) to the inverter with converter assembly.
Install the inverter cover.
Install the inverter terminal cover.
|
| ||||
|
| ||||
| A | |
| 9.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE (FOR MG2) CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Check that the bolts for the motor cable (for MG2) are tightened to the specified torque, the motor cable (for MG2) is connected securely, and there are no contact problems.
Disconnect the motor cable (for MG2) from the inverter with converter assembly.
Check for arc marks at the terminals for the motor cable (for MG2).
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable (for MG2) to the inverter with converter assembly.
Install the inverter terminal cover.
|
| ||||
|
| ||||
| A | |
| 10.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Remove the inverter cover from the inverter with converter assembly.
![]() |
Disconnect the motor cable from the inverter with converter assembly.
![]() |
Check MG1 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a2-1 (W) - a2-2 (U) | Ignition switch off | 139.1 to 153.7 mΩ |
| a2-2 (U) - a2-3 (V) | Ignition switch off | 139.1 to 153.7 mΩ |
| a2-3 (V) - a2-1 (W) | Ignition switch off | 139.1 to 153.7 mΩ |
| *1 | Shield Ground |
| *a | Motor Cable (for MG1) (Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a2-1 (W) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| a2-2 (U) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| a2-3 (V) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
Connect the motor cable.
Install the inverter cover.
Install the inverter terminal cover.
|
| ||||
| OK | |
| 11.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Remove the inverter cover from the inverter with converter assembly.
![]() |
Disconnect the motor cable from the inverter with converter assembly.
![]() |
Check MG2 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a4-1 (W) - a4-2 (U) | Ignition switch off | 172.5 to 190.7 mΩ |
| a4-2 (U) - a4-3 (V) | Ignition switch off | 172.5 to 190.7 mΩ |
| a4-3 (V) - a4-1 (W) | Ignition switch off | 172.5 to 190.7 mΩ |
| *1 | Shield Ground |
| *a | Motor Cable (for MG2) (Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a4-1 (W) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| a4-2 (U) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| a4-3 (V) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
Connect the motor cable.
Install the inverter cover.
Install the inverter terminal cover.
|
| ||||
| OK | |
| 12.CHECK INVERTER WITH CONVERTER ASSEMBLY (FRAME WIRE CONNECTOR CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Remove the inverter cover from the inverter with converter assembly.
![]() |
Check that the bolts for frame wire are tightened to the specified torque, the frame wire is connected securely, and there are no contact problems.
Disconnect the frame wire from the inverter with converter assembly.
Check for arc marks at the bolts and terminals for the frame wire.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the frame wire to the inverter with converter assembly.
Install the inverter cover.
Install the inverter terminal cover.
|
| ||||
|
| ||||
| A | |
| 13.CHECK SERVICE PLUG GRIP (CONNECTION CONDITION) |
Visually check the connection of the service plug grip to the HV battery. Remove the service plug grip and check for contamination.
|
| ||||
| OK | |
| 14.INSPECT SERVICE PLUG GRIP |
Remove the service plug drip.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Service plug grip terminals | Always | Below 1 Ω |
| *1 | Service plug grip |
Install the service plug drip.
|
| ||||
| OK | |
| 15.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (FRAME WIRE CONNECTION CONDITION) |
Check that the service plug grip is not installed.
Remove the No. 1 hybrid vehicle battery cover panel LH .
![]() |
Check that the frame wire connectors are connected securely, and there are no contact problems.
Disconnect the frame wire from the hybrid battery junction block assembly.
Check for arc marks on the terminals of the frame wire.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the frame wire to the hybrid battery junction block assembly.
Install the No. 1 hybrid vehicle battery cover panel LH.
|
| ||||
|
| ||||
| A | |
| 16.CHECK FRAME WIRE |
Check that the service plug grip is not installed.
Remove the No. 1 hybrid vehicle battery cover panel LH .
![]() |
Disconnect the frame wire from the hybrid battery junction block assembly.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Remove the inverter cover from the inverter with converter assembly.
![]() |
Disconnect the frame wire from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| P1-2 (CBI) - P5-1 (CBI) (Positive terminal) | Ignition switch off | Below 1 Ω |
| P1-1 (CEI) - P4-1 (CEI) (Negative terminal) | Ignition switch off | Below 1 Ω |
| *1 | Shield Ground |
| *a | Frame Wire (Inverter with Converter Assembly Side) |
| *b | Frame Wire (Hybrid Battery Junction Block Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| P5-1 (CBI) - Body ground and shielded ground | Ignition switch off | 10 MΩ or higher |
| P4-1 (CEI) - Body ground and shielded ground | Ignition switch off | 10 MΩor higher |
| P5-1 (CBI) - P4-1 (CEI) | Ignition switch off | 10 MΩ or higher |
Connect the frame wire to the hybrid battery junction block assembly.
Connect the frame wire to the inverter with converter assembly.
Install the No. 1 hybrid vehicle battery cover panel LH.
Install the inverter cover.
Install the inverter terminal cover.
|
| ||||
| OK | |
| 17.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRB) |
Check that the service plug grip is not installed.
Remove the hybrid battery junction block assembly (Click here).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A-1 (+) - P5-1 (CBI) | Auxiliary battery voltage is not applied between terminals M40-1 (SMRB) and M40-2 (GND) | 10 kΩ or higher |
| Auxiliary battery voltage is applied between terminals M40-1 (SMRB) and M40-2 (GND) | Below 1 Ω |
| *a | Component without harness connected (Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| M40-1 (SMRB) - M40-2 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
Install the hybrid battery junction block assembly.
|
| ||||
| OK | |
| 18.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRG) |
Check that the service plug grip is not installed.
Remove the hybrid battery junction block assembly (Click here).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| c1-1 (-) - P4-1 (CEI) | Auxiliary battery voltage is not applied between terminals M40-3 (SMRG) and M40-2 (GND) | 10 kΩ or higher |
| Auxiliary battery voltage is applied between terminals M40-3 (SMRG) and M40-2 (GND) | Below 1 Ω |
| *a | Component without harness connected (Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| M40-3 (SMRG) - M40-2 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
Install the hybrid battery junction block assembly.
|
| ||||
| OK | |
| 19.CHECK FUSE (PCU) |
![]() |
Remove the PCU fuse from the No. 2 engine room relay block and No. 2 junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| PCU fuse terminal | Always | Below 1Ω |
| *1 | No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly |
| *2 | PCU fuse |
Install the PCU fuse.
|
| ||||
| OK | |
| 20.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT) |
Check that the service plug grip is not installed.
Disconnect connector A47 from inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-28 (GND1) - Body ground | Ignition switch off | Below 1 Ω |
| A47-27 (GND2) - Body ground | Ignition switch off | Below 1 Ω |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-10 (+B) - Body ground | Ignition switch On (IG) | Same as auxiliary battery voltage |
| A47-9 (+B2) - Body ground | Ignition switch On (IG) | Same as auxiliary battery voltage |
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 21.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU) |
Check that the service plug grip is not installed.
Disconnect connector A47 from the inverter with converter assembly.
Disconnect connector A39 from the power management control ECU.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-8 (HTM+) - A39-24 (HTM+) | Ignition switch off | Below 1 Ω |
| A47-18 (HTM-) - A39-25 (HTM-) | Ignition switch off | Below 1 Ω |
| A47-7 (MTH+) - A39-30 (MTH+) | Ignition switch off | Below 1 Ω |
| A47-17 (MTH-) - A39-29 (MTH-) | Ignition switch off | Below 1 Ω |
| A47-6 (REQ+) - A39-33 (REQ+) | Ignition switch off | Below 1 Ω |
| A47-16 (REQ-) - A39-32 (REQ-) | Ignition switch off | Below 1 Ω |
| A47-5 (CLK+) - A39-21 (CLK+) | Ignition switch off | Below 1 Ω |
| A47-15 (CLK-) - A39-20 (CLK-) | Ignition switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| A47-8 (HTM+) or A39-24 (HTM+) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A47-18 (HTM-) or A39-25 (HTM-) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A47-7 (MTH+) or A39-30 (MTH+) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A47-17 (MTH-) or A39-29 (MTH-) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A47-6 (REQ+) or A39-33 (REQ+) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A47-16 (REQ-) or A39-32 (REQ-) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A47-5 (CLK+) or A39-21 (CLK+) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A47-15 (CLK-) or A39-20 (CLK-) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Rear view of wire harness connector (to Power Management Control ECU) |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-8 (HTM+) or A39-24 (HTM+) - Body ground | Ignition switch ON (IG) | Below 1 V |
| A47-18 (HTM-) or A39-25 (HTM-) - Body ground | Ignition switch ON (IG) | Below 1 V |
| A47-7 (MTH+) or A39-30 (MTH+) - Body ground | Ignition switch ON (IG) | Below 1 V |
| A47-17 (MTH-) or A39-29 (MTH-) - Body ground | Ignition switch ON (IG) | Below 1 V |
| A47-6 (REQ+) or A39-33 (REQ+) - Body ground | Ignition switch ON (IG) | Below 1 V |
| A47-16 (REQ-) or A39-32 (REQ-) - Body ground | Ignition switch ON (IG) | Below 1 V |
| A47-5 (CLK+) or A39-21 (CLK+) - Body ground | Ignition switch ON (IG) | Below 1 V |
| A47-15 (CLK-) or A39-20 (CLK-) - Body ground | Ignition switch ON (IG) | Below 1 V |
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the power management control ECU connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 22.CHECK POWER MANAGEMENT CONTROL ECU |
Disconnect connector A39 from the power management control ECU.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A39-24 (HTM+) - A39-25 (HTM-) | Ignition switch off | 80 to 170 Ω |
| A39-30 (MTH+) - A39-29 (MTH-) | Ignition switch off | 80 to 170 Ω |
| A39-33 (REQ+) - A39-32 (REQ-) | Ignition switch off | 80 to 170 Ω |
| A39-21 (CLK+) - A39-20 (CLK-) | Ignition switch off | 80 to 170 Ω |
| *a | Component without harness connected (Power Management Control ECU) |
Connect the power management control ECU connector.
|
| ||||
| OK | |
| 23.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 24.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | ||
| ||
| 25.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 26.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
![]() |
Disconnect the generator resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) - C24-1 (GRF) | Ignition switch off | Below 1 Ω |
| C28-12 (GRFG) - C24-5 (GRFG) | Ignition switch off | Below 1 Ω |
| C28-7 (GSN) - C24-2 (GSN) | Ignition switch off | Below 1 Ω |
| C28-8 (GSNG) - C24-6 (GSNG) | Ignition switch off | Below 1 Ω |
| C28-10 (GCS) - C24-3 (GCS) | Ignition switch off | Below 1 Ω |
| C28-9 (GCSG) - C24-7 (GCSG) | Ignition switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) or C24-1 (GRF) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-12 (GRFG) or C24-5 (GRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-7 (GSN) or C24-2 (GSN) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-8 (GSNG) or C24-6 (GSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-10 (GCS) or C24-3 (GCS) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-9 (GCSG) or C24-7 (GCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Generator Resolver) |
Connect the generator resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||
| 27.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | |
| 28.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
![]() |
Disconnect the motor resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) - C26-3 (MRF) | Ignition switch off | Below 1 Ω |
| C28-2 (MRFG) - C26-6 (MRFG) | Ignition switch off | Below 1 Ω |
| C28-3 (MSN) - C26-1 (MSN) | Ignition switch off | Below 1 Ω |
| C28-4 (MSNG) - C26-4 (MSNG) | Ignition switch off | Below 1 Ω |
| C28-6 (MCS) - C26-2 (MCS) | Ignition switch off | Below 1 Ω |
| C28-5 (MCSG) - C26-5 (MCSG) | Ignition switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) or C26-3 (MRF) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-2 (MRFG) or C26-6 (MRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-3 (MSN) or C26-1 (MSN) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-4 (MSNG) or C26-4 (MSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-6 (MCS) or C26-2 (MCS) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| C28-5 (MCSG) or C26-5 (MCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Motor Resolver) |
Connect the motor resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||
| 29.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - PCU FUSE) |
Check that the service plug grip is not installed.
Disconnect connector A47 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-10 (+B) - Body ground | Ignition switch off | 10 kΩ or higher |
| A47-9 (+B2) - Body ground | Ignition switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 30.REPLACE INVERTER WITH CONVERTER ASSEMBLY |
| NEXT | ||
| ||
| 31.REPAIR OR REPLACE HARNESS OR CONNECTOR |
| NEXT | ||
| ||
| 32.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE (FOR MG1) CONNECTION CONDITION) |
Check that the service plug grip is not installed.
Remove the inverter with converter assembly (Click here).
![]() |
Check that the bolts for the motor cable (for MG1) are tightened to the specified torque, the motor cable (for MG1) is connected securely, and there are no contact problems.
Disconnect the motor cable (for MG1) from the hybrid vehicle transaxle assembly.
Check for arc marks at the terminals for the motor cable (for MG1).
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable (for MG1) to the hybrid vehicle transaxle assembly.
Install the inverter with converter assembly.
|
| ||||
|
| ||||
| A | |
| 33.CHECK MOTOR CABLE (FOR MG1) |
Check that the service plug grip is not installed.
Remove the motor cable (Click here).
![]() |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a2-1 (W) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| a2-2 (U) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| a2-3 (V) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| *1 | Shield ground |
| *a | Motor Cable (for MG1) (Inverter with Converter Assembly Side) |
| *b | Motor Cable (for MG1) (Hybrid Vehicle Transaxle Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a2-1 (W) - a1-1 (W) | Ignition switch off | Below 1 Ω |
| a2-2 (U) - a1-2 (U) | Ignition switch off | Below 1 Ω |
| a2-3 (V) - a1-3 (V) | Ignition switch off | Below 1 Ω |
| a2-1 (W) - a1-2 (U) | Ignition switch off | 100 MΩ or higher |
| a2-2 (U) - a1-3 (V) | Ignition switch off | 100 MΩ or higher |
| a2-3 (V) - a1-1 (W) | Ignition switch off | 100 MΩ or higher |
Install the motor cable.
|
| ||||
| OK | ||
| ||
| 34.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE (FOR MG2) CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Check that the bolts for the motor cable (for MG2) are tightened to the specified torque, the motor cable (for MG2) is connected securely, and there are no contact problems.
Disconnect the motor cable (for MG2) from the hybrid vehicle transaxle assembly.
Check for arc marks at the terminals for the motor cable (for MG2).
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable (for MG2) to the hybrid vehicle transaxle assembly.
|
| ||||
|
| ||||
| A | |
| 35.CHECK MOTOR CABLE (FOR MG2) |
Check that the service plug grip is not installed.
Remove the motor cable (Click here).
![]() |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a4-1 (W) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| a4-2 (U) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| a4-3 (V) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| *1 | Shield ground |
| *a | Motor Cable (for MG2) (Inverter with Converter Assembly Side) |
| *b | Motor Cable (for MG2) (Hybrid Vehicle Transaxle Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a4-1 (W) - a3-1 (W) | Ignition switch off | Below 1 Ω |
| a4-2 (U) - a3-3 (U) | Ignition switch off | Below 1 Ω |
| a4-3 (V) - a3-2 (V) | Ignition switch off | Below 1 Ω |
| a4-1 (W) - a3-3 (U) | Ignition switch off | 100 MΩ or higher |
| a4-2 (U) - a3-2 (V) | Ignition switch off | 100 MΩ or higher |
| a4-3 (V) - a3-1 (W) | Ignition switch off | 100 MΩ or higher |
Install the motor cable.
|
| ||||
| OK | ||
| ||