POWER STEERING SYSTEM > FREEZE FRAME DATA |
| FREEZE FRAME DATA |
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Turn the Techstream on.
Check the freeze frame data on the Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Meter Vehicle Velocity | Vehicle speed from meter/ Min.: 0.0 km/h (0.0mph) Max.: 300.0 km/h (186.4 mph) | 0 km/h (0 mph) | Ignition switch ON (READY) and vehicle stopped |
| No significant fluctuation | Ignition switch ON (READY) and vehicle driven at constant speed | ||
| Motor Actual Current | Current to motor/ Min.: -327.68 A Max.: 327.67 A | Value changes in proportion to steering effort -The value increases when turning right and decreases when turning left | Ignition switch ON (READY) and steering wheel being turned |
| Command Value Current | Requested current to motor/ Min.: -327.68 A Max.: 327.67 A | Value changes in proportion to steering effort -The value increases when turning right and decreases when turning left | Ignition switch ON (READY) and steering wheel being turned |
| Thermistor Temperature | ECU substrate temperature/ Min.: -50.0°C (-58.0°F) Max.: 150.0°C (302.0°F) | -50 to 150°C (-58 to 302°F) | - |
| PIG Power Supply | Power source voltage to activate motor/ Min.: 0.0000 V Max.: 20.1531 V | 9 to 16 V | Always |
| IG Power Supply | ECU power source voltage/ Min.: 0.0000 V Max.: 20.1531 V | 9 to 16 V | Ignition switch ON (IG) |
| Steering Wheel Torque | Steering wheel torque/ Min.: -327.68 Nm Max.: 7.00 Nm | Value changes in proportion to steering effort -The value increases when turning left and decreases when turning right | Ignition switch ON (READY) and steering wheel being turned |
| Torque Sensor 1 Output | Torque sensor 1 output value/ Min.: 0.0000 V Max.: 4.9725 V | 2.3 to 2.7 V | Ignition switch ON (READY) and steering wheel not being turned (without load) |
| 2.5 to 3.8 V | Ignition switch ON (READY) and steering wheel being turned to right with vehicle stopped | ||
| 1.2 to 2.5 V | Ignition switch ON (READY) and steering wheel being turned to left with vehicle stopped | ||
| Torque Sensor 2 Output | Torque sensor 2 output value/ Min.: 0.0000 V Max.: 4.9725 V | 2.3 to 2.7 V | Ignition switch ON (READY) and steering wheel not being turned (without load) |
| 1.2 to 2.5 V | Ignition switch ON (READY) and steering wheel being turned to right with vehicle stopped | ||
| 2.5 to 3.8 V | Ignition switch ON (READY) and steering wheel being turned to left with vehicle stopped | ||
| TRQ1 Zero Point Value | Zero point value of torque sensor 1/ Min.: 0.0000 V Max.: 4.9725 V | 2.3 to 2.7 V | Ignition switch ON (READY) and steering wheel not being turned (without load) |
| TRQ2 Zero Point Value | Zero point value of torque sensor 2/ Min.: 0.0000 V Max.: 4.9725 V | 2.3 to 2.7 V | Ignition switch ON (READY) and steering wheel not being turned (without load) |
| Motor Terminal Volt(+) | Motor terminal M1 voltage/ Min.: 0.0 V Max.: 25.5 V | 9 to 16 V | Ignition switch ON (READY) and steering wheel being turned to right |
| 6 to 8 V | Ignition switch ON (READY) and steering wheel being turned to left | ||
| Motor Terminal Volt(-) | Motor terminal M2 voltage/ Min.: 0.0 V Max.: 25.5 V | 6 to 8 V | Ignition switch ON (READY) and steering wheel being turned to right |
| 9 to 16 V | Ignition switch ON (READY) and steering wheel being turned to left | ||
| Ready Status | Ready status/ Ready or OFF | READY or OFF | - |