DTC P0A7A-203 Generator Inverter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A7A | 203 | Generator inverter short circuit Current flowing to any of the phases exceeds a certain level after a DTC (indicates a generator inverter malfunction: overheating, overcurrent or circuit malfunction) is stored and the generator inverter is shutdown. (1 trip detection logic) |
|
| Related DTCs | P0A7A (INF 203): GFIV detection (Short circuit malfunction) |
| Required sensors / components | Generator inverter |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| TMC's intellectual property | - |
| Power management control ECU | DTC P0A7A (INF 203) is not detected |

| 1.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Remove the inverter cover from the inverter with converter assembly.
![]() |
Disconnect the motor cable from the inverter with converter assembly.
![]() |
Check MG1 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a2-1 (W) - a2-2 (U) | Ignition switch off | 139.1 to 153.7 mΩ |
| a2-2 (U) - a2-3 (V) | Ignition switch off | 139.1 to 153.7 mΩ |
| a2-3 (V) - a2-1 (W) | Ignition switch off | 139.1 to 153.7 mΩ |
| *1 | Shield Ground |
| *a | Motor Cable (for MG1) (Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a2-1 (W) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| a2-2 (U) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| a2-3 (V) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
Connect the motor cable.
Install the inverter cover.
Install the inverter terminal cover.
|
| ||||
| OK | |
| 2.REPLACE INVERTER WITH CONVERTER ASSEMBLY |
| NEXT | |
| 3.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check the other DTCs that were output together with DTC P0A7A-203.
| DTC No. | Relevant Diagnosis |
| P0A7A-122, 322, 324, 325, 517, 518 | Generator Inverter Performance |
| NEXT | ||
| ||
| 4.CHECK MOTOR CABLE (FOR MG1) |
Check that the service plug grip is not installed.
Remove the motor cable (Click here).
![]() |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a2-1 (W) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| a2-2 (U) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| a2-3 (V) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| *1 | Shield ground |
| *a | Motor Cable (for MG1) (Inverter with Converter Assembly Side) |
| *b | Motor Cable (for MG1) (Hybrid Vehicle Transaxle Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a2-1 (W) - a1-1 (W) | Ignition switch off | Below 1 Ω |
| a2-2 (U) - a1-2 (U) | Ignition switch off | Below 1 Ω |
| a2-3 (V) - a1-3 (V) | Ignition switch off | Below 1 Ω |
| a2-1 (W) - a1-2 (U) | Ignition switch off | 100 MΩ or higher |
| a2-2 (U) - a1-3 (V) | Ignition switch off | 100 MΩ or higher |
| a2-3 (V) - a1-1 (W) | Ignition switch off | 100 MΩ or higher |
Install the motor cable.
|
| ||||
| OK | |
| 5.REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY |
| NEXT | |
| 6.REPLACE INVERTER WITH CONVERTER ASSEMBLY |
| NEXT | |
| 7.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check the other DTCs that were output together with DTC P0A7A-203.
| DTC No. | Relevant Diagnosis |
| P0A7A-122, 322, 324, 325, 517, 518 | Generator Inverter Performance |
| NEXT | ||
| ||
| 8.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1) |
Check that the service plug grip is not installed.
Remove the inverter with converter assembly.
Disconnect the motor cable (for MG1) from the hybrid vehicle transaxle assembly.
![]() |
Check MG1 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a1-1 (W) - a1-2 (U) | Ignition switch off | 136.4 to 150.8 mΩ |
| a1-2 (U) - a1-3 (V) | Ignition switch off | 136.4 to 150.8 mΩ |
| a1-3 (V) - a1-1 (W) | Ignition switch off | 136.4 to 150.8 mΩ |
| *a | Component without motor cable (for MG1) connected (Hybrid Vehicle Transaxle Assembly) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a1-1 (W) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| a1-2 (U) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| a1-3 (V) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
Connect the motor cable.
Install the inverter with converter assembly.
|
| ||||
| OK | |
| 9.REPLACE MOTOR CABLE |
| NEXT | |
| 10.REPLACE INVERTER WITH CONVERTER ASSEMBLY |
| NEXT | |
| 11.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check the other DTCs that were output together with DTC P0A7A-203.
| DTC No. | Relevant Diagnosis |
| P0A7A-122, 322, 324, 325, 517, 518 | Generator Inverter Performance |
| NEXT | ||
| ||
| 12.REPLACE MOTOR CABLE |
| NEXT | |
| 13.REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY |
| NEXT | |
| 14.REPLACE INVERTER WITH CONVERTER ASSEMBLY |
| NEXT | |
| 15.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check the other DTCs that were output together with DTC P0A7A-203.
| DTC No. | Relevant Diagnosis |
| P0A7A-122, 322, 324, 325, 517, 518 | Generator Inverter Performance |
| NEXT | ||
| ||