SOLAR SENSOR > INSPECTION |
| 1. INSPECT COOLER THERMISTOR (SOLAR SENSOR) |
Disconnect the G61 cooler thermistor (solar sensor) connector.
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| G61-1 (SS+) - G61-2 (SS-) | Ignition switch off | Below 1 V |
| G61-1 (SS+) - G61-2 (SS-) | Ignition switch ON (IG) | 4.75 to 5.25 V |
| *a | Front view of wire harness connector (to Cooler Thermistor (Solar Sensor)) |
Reconnect the G61 cooler thermistor (solar sensor) connector.
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| G61-1 (SS+) - G61-2 (SS-) | Sensor is subjected to electric light | 0.8 to 4.3 V |
| G61-1 (SS+) - G61-2 (SS-) | Sensor is covered with a cloth | Below 0.8 V |
| *a | Component with harness connected (Cooler Thermistor (Solar Sensor)) |