DTC P3110-223 HV Main Relay |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P3110 | 223 | IGCT relay stuck on (+B short) IGCT relay is stuck on or a short to B+ exists. Power to the HV ECU does not shut down when the ignition switch is turned off. (1 trip detection logic) |
|

| 1.INSPECT RELAY (IGCT) |
Remove the IGCT relay from the No. 2 engine room relay block and No. 2 junction block assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | Auxiliary battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| *1 | IGCT Relay |
Install the IGCT relay.
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - NO.2 ENGINE ROOM RELAY BLOCK AND NO. 2 JUNCTION BLOCK ASSEMBLY) |
Remove the IGCT relay from the No. 2 engine room relay block and No. 2 junction block assembly.
Disconnect connector A38 and A39 from the power management control ECU.
Measure the voltage according to the value(s) in the table below.

| *1 | No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly | *2 | IGCT relay |
| *a | Rear view of wire harness connector (to Power Management Control ECU) | - | - |
| Tester Connection | Switch Condition | Specified Condition |
| A39-5 (+B1), A38-2 (+B2) or 5 (IGCT relay) - Body ground | Ignition switch off | Below 1 V |
Install the IGCT relay.
Connect the power management control ECU connector.
|
| ||||
| OK | ||
| ||