Home › Engine / Hybrid System › 1NZ-FXE ENGINE CONTROL › CAMSHAFT OIL CONTROL VALVE

CAMSHAFT OIL CONTROL VALVE > REMOVAL

for Preparation Click here



1. REMOVE AIR CLEANER CAP SUB-ASSEMBLY


    A267396
  1. Disconnect the ventilation hose.



    A267397
  1. Disconnect the purge VSV.



    A267398
  1. Disconnect the mass air flow meter connector.

  1. Disconnect the wire harness clamp.

  1. Release the 2 clamps.



    A267400
  1. Loosen the hose clamp and remove the air cleaner cap sub-assembly.



2. REMOVE AIR CLEANER CASE SUB-ASSEMBLY
  1. Remove the air cleaner filter element sub-assembly.



    A267683
  1. Remove the 2 bolts, grommet and air cleaner case sub-assembly.



3. REMOVE CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY


    A267408
  1. Disconnect the camshaft timing oil control valve assembly connector.

  1. Remove the bolt and remove the camshaft timing oil control valve assembly.



    A279116E01
  1. Remove the O-ring from the camshaft timing oil control valve assembly.
    Text in Illustration 
    *1
    O-ring